Daniel Augusto de Faria Almeida

Daniel Augusto de Faria Almeida

Auto-generated profile, based on publicly available information

Daniel Augusto de Faria Almeida

Department of Restorative Dentistry, UNIFAL - Universidade Federal de Alfenas, Alfenas, MG, Brazil

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2015 in Materials Science and Engineering: C
Verified
Journal Article
Closed access
EPEduardo Piza Pellizzer
Eduardo Piza Pellizzer
CMCaroline Cantieri de Mello
Caroline Cantieri de Mello
JJJoel Ferreira Santiago Junior
Joel Ferreira Santiago Junior
VBVictor Eduardo De Souza Batista
Victor Eduardo De Souza Batista
DADaniel Augusto de Faria Almeida
Daniel Augusto de Faria Almeida
FVFelippo Ramos Verri
Felippo Ramos Verri

13 October 2017 in Journal of Medical Engineering & Technology
Verified
Journal Article
Closed access
FVFelippo Ramos Verri
Felippo Ramos Verri
MOMarlice Hayumi Theles Okumura
Marlice Hayumi Theles Okumura
CLCleidiel Aparecido Araujo Lemos
Cleidiel Aparecido Araujo Lemos
DADaniel Augusto de Faria Almeida
Daniel Augusto de Faria Almeida
VBVictor Eduardo De Souza Batista
Victor Eduardo De Souza Batista
EPEduardo Piza Pellizzer
Eduardo Piza Pellizzer
The aim of this study was to evaluate different materials for restoration of teeth without ferrule by three-dimensional (3D) finite element analysis (FEA). Five models simulating the maxillary central incisor and surrounding bone were simulated according to the type of post: glass fibre post (GFP) or cast metal post (CMP) with different alloys such as gold (Au), silver–palladium (AgPd), copper–aluminum (CuAl) and nickel–chromium (NiCr). Models were designed using Invesalius and Rhinoceros. FEAs were made using FEMAP and NeiNastran, with an applied axial force of 100 N and oblique occlusal load at 45°. Stress distribution among groups was analysed by two-way analysis of variance (ANOVA), followed by post-hoc Tukey’s test. The GFP showed the best stress distribution in the post, followed by CMP with Au, AgPd, CuAl and NiCr alloys, respectively (p < .001). No statistically significant difference in the stress distribution in teeth was found under application of axial load (p > .05). Under oblique load, the GFP generated the highest values of tension among the models, followed by the CMP with NiCr alloy than other models (p < .001). The use of GFP resulted in a lower stress concentration in the post, but increased stress in the tooth without ferrule. The CMP with NiCr alloy exhibited the highest stress distribution among other CMP. To avoid higher stress in teeth, alloys of Au, AgPd and CuAl, respectively, are recommended.

1 February 2018 in Brazilian Dental Journal
Verified
Journal Article
Open access
CLCleidiel Aparecido Araujo Lemos
Cleidiel Aparecido Araujo Lemos
FVFelippo Ramos Verri
Felippo Ramos Verri
JJJOEL FERREIRA SANTIAGO JUNIOR
JOEL FERREIRA SANTIAGO JUNIOR
DADaniel Augusto de Faria Almeida
Daniel Augusto de Faria Almeida
VBVictor Eduardo De Souza Batista
Victor Eduardo De Souza Batista
EPEduardo Piza Pellizzer
Eduardo Piza Pellizzer
The purpose of this study was to evaluate different retention systems (cement- or screw-retained) and crown designs (non-splinted or splinted) of fixed implant-supported restorations, in terms of stress distributions in implants/components and bone tissue, by 3-dimensional (3D) finite element analysis. Four 3D models were simulated with the InVesalius, Rhinoceros 3D, and SolidWorks programs. Models were made of type III bone from the posterior maxillary area. Models included three 4.0-mm-diameter Morse taper (MT) implants with different lengths, which supported metal-ceramic crowns. Models were processed by the Femap and NeiNastran programs, using an axial force of 400 N and oblique force of 200 N. Results were visualized as the von Mises stress and maximum principal stress (σmax). Under axial loading, there was no difference in the distribution of stress in implants/components between retention systems and splinted crowns; however, in oblique loading, cemented prostheses showed better stress distribution than screwed prostheses, whereas splinted crowns tended to reduce stress in the implant of the first molar. In the bone tissue cemented prostheses showed better stress distribution in bone tissue than screwed prostheses under axial and oblique loading. The splinted design only had an effect in the screwed prosthesis, with no influence in the cemented prosthesis. Cemented prostheses on MT implants showed more favorable stress distributions in implants/components and bone tissue. Splinting was favorable for stress distribution only for screwed prostheses under oblique loading.

13 April 2014 in Applied Physics B
Verified
Journal Article
Closed access
PDF file
EPEduardo Piza Pellizzer
Eduardo Piza Pellizzer
JJJoel Ferreira Santiago Junior
Joel Ferreira Santiago Junior
LVLuiz Marcelo Ribeiro Villa
Luiz Marcelo Ribeiro Villa
VBVictor Eduardo De Souza Batista
Victor Eduardo De Souza Batista
CMCaroline Cantieri de Mello
Caroline Cantieri de Mello
Heitor Marques HonórioHeitor Marques Honório
Heitor Marques Honório

1 June 2017 in Journal of Craniofacial Surgery
Verified
Journal Article
Closed access
EPEduardo Piza Pellizzer
Eduardo Piza Pellizzer
MGMarcelo Coelho Coelho Goiato
Marcelo Coelho Coelho Goiato
DADaniel Augusto de Faria Almeida
Daniel Augusto de Faria Almeida
RFRosse Mary Falcon-Antenucci
Rosse Mary Falcon-Antenucci
CLCleidiel Aparecido Araujo Lemos
Cleidiel Aparecido Araujo Lemos
FVFelippo Ramos Verri
Felippo Ramos Verri
The aim of this study was to report a patient of rehabilitation with removable partial denture retained by implants in-patient who suffered injury after firearm shooting. A 19-year-old man presented to the hospital of the Val Paraíso city after being hit by a bullet in the right on the face, affecting the teeth 12 to 16. The surgery to remove the shards of teeth, and bullet was performed. Surgical team opted for installation of implants without bone grafts; however, due to extensive loss of alveolar bone, only 3 tilted implants (2 Ø3.75 × 8.5 mm and 1 Ø3.75 × 10 mm) were installed. After recovery, the patient was referred to the Araçatuba Dental School-UNESP for the rehabilitation on the affected region. The difficulty of rehabilitation with conventional fixed prostheses was verified during the prosthetic phase. This way, it was opted for rehabilitation with removable partial dentures associated with dental implant. Two attachment system ERA (ERA, Sterngold) were positioned in the bar to make the removable partial denture. After 5 years of follow-up, the authors can conclude that the use of removable partial denture retained by implants is effective for functional and aesthetic rehabilitation, favoring socialization and self-esteem of the patient.