Josef Goding

Josef Goding

Auto-generated profile, based on publicly available information

Josef Goding

Imperial College London

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 December 2018 in Journal of Materials Chemistry B
Verified
Journal Article
Closed access
PDF file
JGJosef Goding
Josef Goding
Catalina Vallejo-GiraldoCatalina Vallejo-Giraldo
Catalina Vallejo-Giraldo
OSOmaer Syed
Omaer Syed
Rylie A.  GreenRylie A. Green
Rylie A. Green
Hydrogels have been applied across a wide range of biomedical applications due to their versatility, but more recently have garnered interest as materials in bioelectronics due to the capacity to tailor their mechanical and biological properties. Hydrogel coatings in particular have been used to impart softness at the bionic device interface, deliver therapeutics and control cell interactions through presentation of peptides and growth factors. Additionally, the use of dynamic hydrogel properties has been harnessed as shuttles for the implantation of flexible electrode arrays. In all of these applications, the hydrogel must be designed not only to provide the desired performance, but also have no unexpected impacts on the surrounding tissues, such as extensive swelling that can compress the cells at the interface. Appropriate selection and design of hydrogel systems for bioelectronics requires an understanding of the physical, chemical and biological properties of hydrogels as well as their structure–property relationships. This review covers the design rationale for application of hydrogels systems for use in bioelectronic devices with a focus on in vivo applications.

1 February 2022 in Acta Biomaterialia
Verified
Journal Article
Open access
JHJulian Heck
Julian Heck
JGJosef Goding
Josef Goding
RLRoberto Portillo Lara
Roberto Portillo Lara
Rylie A.  GreenRylie A. Green
Rylie A. Green
Conducting polymers (CPs) possess unique electrical and electrochemical properties and hold great potential for different applications in the field of bioelectronics. However, the widespread implementation of CPs in this field has been critically hindered by their poor processibility. There are four key elements that determine the processibility of CPs, which are thermal tunability, chemical stability, solvent compatibility, and mechanical robustness. Recent research efforts have focused on enhancing the processibility of these materials through the pre- or post-synthesis chemical modifications, the fabrication of CP-based complexes and composites, and the adoption of additive manufacturing techniques. In this review, the physicochemical and structural properties that underlie the performance and processibility of CPs are examined. In addition, current research efforts to overcome technical limitations and broaden the potential applications of CPs in bioelectronics are discussed.

1 September 2023 in APL Bioengineering
Verified
Journal Article
Open access
PDF file
NSNicolas Steenbergen
Nicolas Steenbergen
IBIvan Busha
Ivan Busha
AMAlexis Morgan
Alexis Morgan
CMCollin Mattathil
Collin Mattathil
APArieh Levy Pinto
Arieh Levy Pinto
Rylie A.  GreenRylie A. Green
Rylie A. Green
Conventional wet Ag/AgCl electrodes are widely used in electrocardiography, electromyography (EMG), and electroencephalography (EEG) and are considered the gold standard for biopotential measurements. However, these electrodes require substantial skin preparation, are single use, and cannot be used for continuous monitoring (>24 h). For these reasons, dry electrodes are preferable during surface electromyography (sEMG) due to their convenience, durability, and longevity. Dry conductive elastomers (CEs) combine conductivity, flexibility, and stretchability. In this study, CEs combining poly(3,4-ehtylenedioxythiophene):polystyrenesulfonate (PEDOT:PSS) in polyurethane are explored as dry, skin contacting EMG electrodes. This study compares these CE electrodes to commercial wet Ag/AgCl electrodes in five subjects, classifying four movements: open hand, fist, wrist extension, and wrist flexion. Classification accuracy is tested using a backpropagation artificial neural network. The control Ag/AgCl electrodes have a 98.7% classification accuracy, while the dry conductive elastomer electrodes have a classification accuracy of 99.5%. As a conclusion, PEDOT based dry CEs were shown to successfully function as on-skin electrodes for EMG recording, matching the performance of Ag/AgCl electrodes, while addressing the need for minimal skin prep, no gel, and wearable technology.


28 May 2024 in APL Bioengineering
Verified
Journal Article
Open access
PDF file
Yael HaneinYael Hanein
Yael Hanein
JGJosef Goding
Josef Goding
The realm of implantable bioelectronics represents a frontier in medical science, merging technology, biology, and medicine to innovate treatments that enhance, restore, or monitor physiological functions. This field has yielded devices like cochlear implants, cardiac pacemakers, deep brain stimulators, and vagus nerve stimulators, each designed to address a specific health condition, ranging from sensorineural hearing loss to chronic pain, neurological disorders, and heart rhythm irregularities. Such devices underscore the potential of bioelectronics to significantly improve patient outcomes and quality of life. Recent technological breakthroughs in materials science, nanotechnology, and microfabrication have enabled the development of more sophisticated, smaller, and biocompatible bioelectronic devices. However, the field also encounters challenges, particularly in extending the capabilities of devices such as retinal prostheses, which aim to restore vision but currently offer limited visual acuity. Research in implantable bioelectronics is highly timely, driven by an aging global population with a growing prevalence of chronic diseases that could benefit from these technologies. The convergence of societal health needs, advancing technological capabilities, and a supportive ecosystem for innovation marks this era as pivotal for bioelectronic research.

28 November 2023 in Materials Today Bio
Verified
Journal Article
Open access
CCChristopher A.R. Chapman
Christopher A.R. Chapman
SFShanila Fernandez-Patel
Shanila Fernandez-Patel
NJNusrat Jahan
Nusrat Jahan
ECEstelle A. Cuttaz
Estelle A. Cuttaz
ANAlexey Novikov
Alexey Novikov
Rylie A.  GreenRylie A. Green
Rylie A. Green
This work highlights the development of a conductive elastomer (CE) based electrophoretic platform that enables the transfer of charged molecules from a solid-state CE electrode directly to targeted tissues. Using an elastomer-based electrode containing poly (3,4-ethylenedioxythiophene) nanowires, controlled electrophoretic delivery of methylene blue (MB) and fluorescein (FLSC) was achieved with applied voltage. Electroactive release of positively charged MB and negatively charged FLSC achieved 33.19 ± 6.47 μg release of MB and 22.36 ± 3.05 μg release of FLSC, a 24 and 20-fold increase in comparison to inhibitory voltages over 1 h. Additionally, selective, and sequential release of the two oppositely charged molecules from a single CE device was demonstrated, showing the potential of this device to be used in multi-drug treatments.