Nicholas E. Bishop

Nicholas E. Bishop

Auto-generated profile, based on publicly available information

Nicholas E. Bishop

Biomechanics Section, TUHH Hamburg University of Technology, Denickestraße 15, 21073 Hamburg, Germany. address for F. Witt:. address for N.E. Bishop:. address for M.M. Morlock:

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 February 2013 in Journal of Orthopaedic Research
Verified
Journal Article
Open access
PDF file
NBNicholas Bishop
Nicholas Bishop
FWFlorian Witt
Florian Witt
RPRobin Pourzal
Robin Pourzal
AFAlfons Fischer
Alfons Fischer
MRMarcel Rütschi
Marcel Rütschi
MMMichael Morlock
Michael Morlock
Wear of the modular taper between head and shaft has been related to clinical failure resulting from adverse reactions to metallic debris. The problem has become pronounced in large metal‐on‐metal bearings, but the mechanism has not yet been fully understood. We analyzed retrieved components from five patients revised with various diagnoses. Two distinct wear patterns were observed for the head tapers. Three samples demonstrated “asymmetric” wear towards the inner end of the head taper. The other two showed “axisymmetric” radial wear (up to 65 µm) presenting the largest wear volumes (up to 20 mm3). Stem tapers demonstrated relatively little wear, and the fine thread on the stem taper surface was observed to be imprinted on the taper inside of the head. Our findings demonstrate that the cobalt‐chrome head wears preferentially to the titanium stem taper. “asymmetric” wear suggests toggling due to the offset of the joint force vector from the taper. In contrast, samples with “axisymmetric” radial wear and a threaded imprint suggested that corrosion led to head subsidence onto the stem taper with gradual rotation. © 2013 Orthopaedic Research Society Published by Wiley Periodicals, Inc. J Orthop Res 31:1116–1122, 2013

13 December 2012 in Journal of Orthopaedic Research
Verified
Journal Article
Open access
PDF file
NBNicholas E. Bishop
Nicholas E. Bishop
AHArne Hothan
Arne Hothan
MMMichael Morlock
Michael Morlock
Disappointing clinical results for large diameter metal replacement bearings for the hip are related to compromised lubrication due to poor cup placement, which increases wear as well as friction moments. The latter can cause overload of the implant–bone interfaces and the taper junction between head and stem. We investigated the influence of lubrication conditions on friction moments in modern hip bearings. Friction moments for large diameter metal and ceramic bearings were measured in a hip simulator with cup angles varying from 0° to 60°. Two diameters were tested for each bearing material, and measurements were made in serum and in dry conditions, representing severely compromised lubrication. Moments were lower for the ceramic bearings than for the metal bearings in lubricated conditions, but approached those for metal bearings at high cup inclination. In dry conditions, friction moments increased twofold to 12 Nm for metal bearings. For ceramic bearings, the increase was more than fivefold to over 25 Nm. Although large diameter ceramic bearings demonstrate an improvement in friction characteristics in the lubricated condition, they could potentially replicate problems currently experienced due to high friction moments in metal bearings once lubrication is compromised. © 2012 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 31: 807–813, 2013

17 September 2014 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
PDF file
FWF. Witt
F. Witt
BBB.H. Bosker
B.H. Bosker
NBN.E. Bishop
N.E. Bishop
HEH.B. Ettema
H.B. Ettema
CVC.C.P.M. Verheyen
C.C.P.M. Verheyen
MMMichael Morlock
Michael Morlock
Background: Revision of hip implants due to adverse tissue reactions to metal debris has been associated with wear and corrosion of the metal-on-metal bearing articulation and the modular taper interface. Bearing articulation wear is increased in conditions of poor lubrication, which can also lead to high friction moments that may cause corrosion at the taper interface. This suggests that wear of the bearing and increased corrosion of the taper interface should occur simultaneously, which was investigated in this study. Methods: Forty-three large-diameter cobalt-chromium bearings of the same design, implanted with a titanium stem using a titanium adapter, were retrieved at revision at a single center. Retrievals were grouped according to visual inspection of the female taper surface of the adapter into slight and severe corrosion groups. Volume change of bearing and taper surfaces was assessed using a coordinate measurement machine. Serum ion concentrations were determined for forty-three patients, whereas tissue metal concentration was measured for twelve patients. Results: Severe taper corrosion was observed in 30% of the retrievals. Corrosion was observed either as material deposition or wear. The overall bearing wear rate was significantly higher in the group with severe taper corrosion than in the group with slight corrosion (7.2 ± 9.0 mm3/yr versus 3.1 ± 6.8 mm3/yr, respectively; p = 0.023) as were the serum cobalt (40.5 ± 44.9 μg/L versus 15.2 ± 23.9 μg/L, respectively; p = 0.024) and chromium ion concentrations (32.7 ± 32.7 μg/L versus 12.0 ± 15.1 μg/L, respectively; p = 0.019). Serum metal ion concentrations were more consistent indicators of wear than tissue metal concentrations. Conclusions: The increased bearing articulation wear and serum metal ion concentrations in cases with taper interface corrosion support the hypothesis that increased friction in the joint articulation is one of the factors responsible for simultaneous articulation and taper damage. However, independent taper or bearing damage was also observed, suggesting that other factors are involved in the process.

4 March 2008 in Medical Engineering & Physics
Verified
Journal Article
Closed access
NBN.E. Bishop
N.E. Bishop
FWF. Waldow
F. Waldow
MMMichael Morlock
Michael Morlock
Modern hip joint replacements are designed to minimise wear problems. The most popular metal-on-polyethylene components are being updated by harder metal and ceramic combinations. However, this has also been shown to influence the friction moments, which could overload the interface between the implant and the body. In this study custom test apparatus was used to measure the joint moments in various modern bearings under simulated physiological joint conditions. The largest moments in serum were measured for large diameter metal-metal bearings (<8 Nm for standard bearings), followed by metal-polyethylene, and the lowest moments were for small diameter ceramic-ceramic and ceramic-metal combinations. Water as a lubricant was found to double the moments in comparison with serum. In metal-metal bearings moments were reduced by increasing loading frequency. Swing phase load and a rest period between load cycles had little effect. The moment magnitudes are within the turn-out capacity measured for press-fit cups and might become critical with higher joint loads.

1 April 2014 in Journal of Biomechanics
Verified
Journal Article
Closed access
NBNicholas E. Bishop
Nicholas E. Bishop
JHJan-Christian Höhn
Jan-Christian Höhn
SRStephan Rothstock
Stephan Rothstock
NDNiklas B. Damm
Niklas B. Damm
MMMichael Morlock
Michael Morlock

1 August 2010 in Clinical Biomechanics
Verified
Journal Article
Closed access
NBNicholas E. Bishop
Nicholas E. Bishop
ABAndrew Burton
Andrew Burton
MMMarci Maheson
Marci Maheson
MMMichael Morlock
Michael Morlock