Syed Saud Naqvi

Syed Saud Naqvi

Auto-generated profile, based on publicly available information

Syed Saud Naqvi

Department of Electrical and Computer Engineering, COMSATS University Islamabad (CUI), Islamabad, Pakistan

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2019 in Expert Systems with Applications
Verified
Journal Article
Closed access
ZRZaka Ur Rehman
Zaka Ur Rehman
SNSyed S. Naqvi
Syed S. Naqvi
TKTarqi Khan
Tarqi Khan
MKMuhammad A. Khan
Muhammad A. Khan
TBTariq Bashir
Tariq Bashir

1 January 2021 in IEEE Access
Verified
Journal Article
Open access
ASAfshan Shah
Afshan Shah
SNSyed Saud Naqvi
Syed Saud Naqvi
Khuram NaveedKhuram Naveed
Khuram Naveed
NSNema Salem
Nema Salem
MKMohammad Asmat Ullah Khan
Mohammad Asmat Ullah Khan
KAKhurram Saleem Alimgeer
Khurram Saleem Alimgeer
Leukemia is the rapid production of abnormal white blood cells that consequently affects the blood and damages the bone marrow. The overproduction of abnormal and immature white blood cells leads to the damage of the immune system due to the reduced production of red blood cells and platelets by the bone marrow of the body. This hematological malignancy is generally diagnosed by manual methods such as complete blood count (CBC), bone marrow aspiration, or microscopic examination of the blood smear. Nevertheless, the manual methods of leukemia diagnosis are economical but are found to be less reliable, time-consuming, and hectic. Technological advancement in the medical field has effectively addressed these issues in the past. The problems in the manual diagnosis of leukemia detection have been overcome by the development of automated methods using the computer-aided diagnostic (CAD) systems for efficient and reliable leukemia diagnosis. Since the last decade, multiple approaches have been proposed for the CAD systems regarding pre-processing, segmentation, feature extraction, feature selection, and for the improvement of the classification accuracy of the CAD system for the leukemia detection. This paper presents a comprehensive review of the CAD systems for the detection of the various types of leukemia. The review presented here entails the details of various CAD systems for the automated diagnosis of various types of leukemia and analyses their methodologies in terms of their efficiency in pre-processing, segmentation, feature extraction and selection, and overall classification accuracy of the CAD system.

1 January 2020 in IEEE Access
Verified
Journal Article
Open access
TKTarqi Khan
Tarqi Khan
MAMusaed Alhussein
Musaed Alhussein
KAKhursheed Aurangzeb
Khursheed Aurangzeb
MAMuhammad Arsalan
Muhammad Arsalan
SNSyed Saud Naqvi
Syed Saud Naqvi
JSJunaid Nawaz Syed
Junaid Nawaz Syed
Devising automated procedures for accurate vessel segmentation (retinal) is crucial for timely prognosis of vision-threatening eye diseases. In this paper, a novel supervised deep learning-based approach is proposed which extends a variant of the fully convolutional neural network. The existing fully convolutional neural network-based counterparts have associated critical drawbacks of involving a large number of tunable hyper-parameters and an increased end-to-end training time furnished by their decoder structure. The proposed approach addresses these intricate challenges by using a skip-connections strategy by sharing indices obtained through max-pooling to the decoder from the encoder stage (respective stages) for enhancing the resolution of the feature map. This significantly reduces the number of required tunable hyper-parameters and the computational overhead of the training as well as testing stages. Furthermore, the proposed approach particularly helps in eradicating the requirement for employing both post-processing and pre-processing steps. In the proposed approach, the retinal vessel segmentation problem is formulated as a semantic pixel-wise segmentation task which helps in spanning the gap between semantic segmentation and medical image segmentation. A prime contribution of the proposed approach is the introduction of external skip-connection for passing the preserved low-level semantic edge information in order to reliably detect tiny vessels in the retinal fundus images. The performance of the proposed scheme is analyzed based on the three publicly available notable fundus image datasets, while the widely recognized evaluation metrics of specificity, sensitivity, accuracy, and the Receiver Operating Characteristics curves are used. Based on the assessment of the images in {DRIVE, CHASE_DB1, and STARE}; datasets, the proposed approach achieves a sensitivity, specificity, accuracy, and ROC performance of {0.8252, 0.8440, and 0.8397};, {0.9787, 0.9810, and 0.9792};, {0.9649, 0.9722, and 0.9659};, and {0.9780, 0.9830, and 0.9810};, respectively. The reduced computational complexity and memory overhead along with improved segmentation performance advocates employing the proposed approach in the automated diagnostic systems for eye diseases.

23 February 2021 in IEEE Access
Verified
Journal Article
Open access
FDFaizan Daud
Faizan Daud
RIRakhshanda Imtiaz
Rakhshanda Imtiaz
Hussain Ahmad MadniHussain Ahmad Madni
Hussain Ahmad Madni
HKHaroon Ahmed Khan
Haroon Ahmed Khan
TKTarqi Khan
Tarqi Khan
FAFaizan Abdullah
Faizan Abdullah
Glaucoma is an incurable eye disease that leads to slow progressive degeneration of the retina. It cannot be fully cured, however, its progression can be controlled in case of early diagnosis. Unfortunately, due to the absence of clear symptoms during the early stages, early diagnosis are rare. Glaucoma must be detected at early stages since late diagnosis can lead to permanent vision loss. Glaucoma affects the retina by damaging the Optic Nerve Head (ONH). Its diagnosis is dependent on the measurements of Optic Cup (OC) and Optic Disc (OD) in the retina. Computer vision techniques have been shown to diagnose glaucoma effectively and correctly with little overhead. These techniques measure OC and OC dimensions using machine learning based classification and segmentation algorithms. This article aims to provide a comprehensive overview of various existing techniques that use machine learning to detect and diagnose glaucoma based on fundus images. Readers would be able to understand the challenges glaucoma presents from an image processing and machine learning stand-point and will be able to identify gaps in current research.

13 November 2019 in IEEE Access
Verified
Journal Article
Open access
AKAhsan Khawaja
Ahsan Khawaja
TKTarqi Khan
Tarqi Khan
Khuram NaveedKhuram Naveed
Khuram Naveed
SNSyed Saud Naqvi
Syed Saud Naqvi
NRNaveed Rehman
Naveed Rehman
JSJunaid Nawaz Syed
Junaid Nawaz Syed
Vessel segmentation has come a long way in terms of matching the experts at detection accuracy, yet there is potential for further improvement. In this regard, the accurate detection of vessels is generally more challenging due to the high variations in vessel contrast, width, and the observed noise level. Most vessel segmentation strategies utilize contrast enhancement as a preprocessing step, which has an inherent tendency to aggravate the noise and therefore, impede accurate vessel detection. To alleviate this problem, we propose to use the state-of-the-art Probabilistic Patch-Based (PPB) denoiser within the framework of an unsupervised retinal vessel segmentation strategy based on the Frangi filter. The PPB denoiser helps preserve vascular structure while effectively dealing with the amplified noise. Also, the modified Frangi filter is evaluated separately for tiny and large vessels, followed by individual segmentation and linear recombination of the binarized outputs. This way, the performance of the modified Frangi filter is significantly enhanced. The performance evaluation of the proposed method is evaluated on two recognized open-access datasets, viz: DRIVE and STARE. The proposed strategy yields competitive results for both preprocessing modalities, i.e., Contrast Limited Adaptive Histogram Equalization (CLAHE) and Generalized Linear Model (GLM). The performance observed for CLAHE over DRIVE and STARE datasets is (Sn = 0.8027, Acc = 0.9561) and (Sn = 0.798, Acc = 0.9561), respectively. For GLM, it is observed to be (Sn = 0.7907, Acc = 0.9603) and (Sn = 0.7860, Acc = 0.9583) over DRIVE and STARE datasets, respectively. Furthermore, based on the conducted comparative study, it is established that the proposed method outperforms various notable vessel segmentation methods available in the existing literature.

1 April 2019 in Expert Systems with Applications
Verified
Journal Article
Closed access
ZRZaka Ur Rehman
Zaka Ur Rehman
SNSyed S. Naqvi
Syed S. Naqvi
TKTarqi Khan
Tarqi Khan
MAMuhammad Arsalan
Muhammad Arsalan
MKMuhammad A. Khan
Muhammad A. Khan
MKM.A. Khalil
M.A. Khalil