Guizhong Wang

Guizhong Wang

Auto-generated profile, based on publicly available information

Guizhong Wang

Industrial and Technological Research Institute of HIT (Zhangjiakou), Zhangjiakou, China 075421

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 December 2020 in IEEE Transactions on Transportation Electrification
Verified
Journal Article
Closed access
SLSuhua Luo
Suhua Luo
FWfengjiang wu
fengjiang wu
GWGuizhong Wang
Guizhong Wang
As the key part of the electrical vehicle charger with the V2G functions, the isolated dual-active bridge (DAB) DC-DC converter should possesses a good current characteristics. The cooperative triple-phase-shift (CTPS) modulation for DAB converter realizes the best inductor current performance. However, the dead band and transient actions deteriorate the actual performance of the CTPS. In this paper, the effect is analyzed for the first time and the analysis results indicate that both the dead band and transient actions cause the DC-bias inductor current and the DC-side flow back currents. The corresponding solutions to eliminate these effects are proposed accordingly. First, a phase-shift compensation related to the dead time is added to the ideal phase shifts from CTPS to eliminate the effect of dead band. Secondly, the relationship between the three phase shifts are recalculated considering the old values of the phase shifts to eliminate the transient DC bias currents and flow back currents. The proposed solutions are validated in detail in the experimental way.

12 March 2020 in IEEE Access
Verified
Journal Article
Open access
YCYue Chen
Yue Chen
ZGZhizhong Guo
Zhizhong Guo
HLHongbo Li
Hongbo Li
YYYi Yang
Yi Yang
GWGuizhong Wang
Guizhong Wang
ZDZhe Ding
Zhe Ding
The power prediction error of uncertain renewable energy sources (URESs) affects the power balance of a power grid. In the power systems with high proportion renewable power sources (PSHPRPSs), automatic generation control (AGC) cannot accommodate the day-ahead power prediction error. The dispatching control system (DCS) of PSHPRPSs adds real-time dispatching links to modify the day-ahead dispatching plan so that the grid power error is within the range of AGC accommodation. This paper proposes a critical time scale (CTS) selection algorithm based on time aggregation characteristics for real-time dispatching of PSHPRPSs and calculates the annual CTS of real-time dispatching of power grids. The uncertainty function is used to describe the relationship between the prediction error of the URESs and the prediction lead time. The total uncertainty function is calculated based on the time aggregation characteristics and is used to select the annual CTS of real-time dispatching. The proposed algorithm quantitatively describes the relationship between the CTS and the operation proportion of URESs and also AGC accommodation capacity. The calculated annual CTS not only ensures the power balance of the power grid, but also avoids the daily change of the CTS. Using the data of URESs in the Irish power grid, the feasibility of the proposed method was verified. The research results of this paper are helpful to accommodate the day-ahead power prediction error of URESs and maintain the safe operation of power grid.