Dan Wang

Dan Wang

Auto-generated profile, based on publicly available information

Dan Wang

National Key Laboratory of Science and Technology on Helicopter Transmission, Nanjing University of Aeronautics and Astronautics, Nanjing, China

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 February 2020 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
Yaoyao WangYaoyao Wang
Yaoyao Wang
SLShizhen Li
Shizhen Li
DWDan Wang
Dan Wang
FJFeng Ju
Feng Ju
BCBai Chen
Bai Chen
HWHongtao Wu
Hongtao Wu
For high control performance of cable-driven manipulators, we design a new adaptive time-delay control (ATDC) using enhanced nonsingular fast terminal sliding mode (NFTSM). The proposed ATDC uses time-delay estimation (TDE) to acquire the lumped dynamics in a simple way and founds a practical model-free structure. Then, a new enhanced NFTSM surface is developed to ensure fast convergence and high control accuracy. To acquire good comprehensive performance under lumped uncertainties, in this article we propose a novel adaptive algorithm for the control gain, which can regulate itself based on the control errors timely and accurately. Benefitting from the TDE and the proposed enhanced NFTSM surface and adaptive control gain, our proposed ATDC is model-free, fast response, and accurate. Theoretical analysis concerning system stability, and control precision and convergence speed are given based on Lyapunov theory. Finally, the advantages of our ATDC over existing methods are verified with comparative experiments.

18 November 2020 in Sensors
Verified
Journal Article
Open access
PDF file
YZYingxuan Zhang
Yingxuan Zhang
FJFeng Ju
Feng Ju
XWXiaoyong Wei
Xiaoyong Wei
DWDan Wang
Dan Wang
Yaoyao WangYaoyao Wang
Yaoyao Wang
In this paper, a piezoelectric tactile sensor for detecting tissue stiffness in robot-assisted minimally invasive surgery (RMIS) is proposed. It can detect the stiffness not only when the probe is normal to the tissue surface, but also when there is a contact angle between the probe and normal direction. It solves the problem that existing sensors can only detect in the normal direction to ensure accuracy when the degree of freedom (DOF) of surgical instruments is limited. The proposed senor can distinguish samples with different stiffness and recognize lump from normal tissue effectively when the contact angle varies within [0°, 45°]. These are achieved by establishing a new detection model and sensor optimization. It deduces the influence of contact angle on stiffness detection by sensor parameters design and optimization. The detection performance of the sensor is confirmed by simulation and experiment. Five samples with different stiffness (including lump and normal samples with close stiffness) are used. Through blind recognition test in simulation, the recognition rate is 100% when the contact angle is randomly selected within 30°, 94.1% within 45°, which is 38.7% higher than the unoptimized sensor. Through blind classification test and automatic k-means clustering in experiment, the correct rate is 92% when the contact angle is randomly selected within 45°. We can get the proposed sensor can easily recognize samples with different stiffness with high accuracy which has broad application prospects in the medical field.

18 March 2023 in Chinese Journal of Aeronautics
Verified
Journal Article
Open access
HZhaimin zhu
haimin zhu
LZLi Zhang
Li Zhang
QCQingzhang Chen
Qingzhang Chen
MLMiaomiao Li
Miaomiao Li
DWDan Wang
Dan Wang
RZRupeng Zhu
Rupeng Zhu

2 September 2022 in Nonlinear Dynamics
Verified
Journal Article
Closed access
PDF file
DWDan Wang
Dan Wang
LSLiyao Song
Liyao Song
RZRupeng Zhu
Rupeng Zhu
PCPeng Cao
Peng Cao

16 May 2017 in Smart Materials and Structures
Verified
Journal Article
Closed access
PDF file
DWDan Wang
Dan Wang
LWLinxiang Wang
Linxiang Wang
Roderick MelnikRoderick Melnik
Roderick Melnik
Different from the traditional piezoelectric vibration energy harvesting, a new strategy based on stress-induced polarization switching has been proposed in the current paper. Two related prototypes are presented and the associated advantages and drawbacks have been discussed in detail. It has been demonstrated that, with the assistance of a bias electric field, the robustness of the energy harvesters is improved. Furthermore, the real-space phase-field model has been employed to study the nonlinear hysteretic behavior involved in the proposed energy harvesting process. A substantially larger electric current associated with the stress-induced polarization switching has been demonstrated when compared with that with piezoelectric effect. In addition, the effects of bias electric potential, bias resistance, mechanical boundary conditions, charge leakage and electrodes arrangements have also been investigated by the phase-field simulation, which provides a guidance for future real implementations.

1 December 2022 in International Journal of Mechanics and Materials in Design
Verified
Journal Article
Closed access
PDF file
DWDan Wang
Dan Wang
LSLiyao Song
Liyao Song
PCPeng Cao
Peng Cao
RZRupeng Zhu
Rupeng Zhu