Luigi Pio Rignanese

Luigi Pio Rignanese

Auto-generated profile, based on publicly available information

Luigi Pio Rignanese

INFN Sezione di Bologna, Bologna

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2016 in Journal of Instrumentation
Verified
Journal Article
Open access
PDF file
AAA. Adamczak
A. Adamczak
GBGiovanni Baccolo
Giovanni Baccolo
DBD. Bakalov
D. Bakalov
GBG. Baldazzi
G. Baldazzi
RBR. Bertoni
R. Bertoni
MZM. Zuffa
M. Zuffa
The high precision measurement of the hyperfine splitting of the muonic-hydrogen atom ground state with pulsed and intense muon beam requires careful technological choices both in the construction of a gas target and of the detectors. In June 2014, the pressurized gas target of the FAMU experiment was exposed to the low energy pulsed muon beam at the RIKEN RAL muon facility. The objectives of the test were the characterization of the target, the hodoscope and the X-ray detectors. The apparatus consisted of a beam hodoscope and X-rays detectors made with high purity Germanium and Lanthanum Bromide crystals. In this paper the experimental setup is described and the results of the detector characterization are presented.

29 August 2024 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Open access
FCFabio Cossio
Fabio Cossio
BAB.R. Achari
B.R. Achari
NAN. Agrawal
N. Agrawal
MAM. Alexeev
M. Alexeev
CAC. Alice
C. Alice
RWR. Wheadon
R. Wheadon

1 October 2014 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
LALucia Andreani
Lucia Andreani
MBMarco Bontempi
Marco Bontempi
PRPier Luca Rossi
Pier Luca Rossi
LRLuigi Pio Rignanese
Luigi Pio Rignanese
MZMirco Zuffa
Mirco Zuffa
GBGiuseppe Baldazzi
Giuseppe Baldazzi

1 February 2024 in Journal of Instrumentation
Verified
Journal Article
Open access
LRLuigi Pio Rignanese
Luigi Pio Rignanese
NANeelima Agrawaal
Neelima Agrawaal
MAMaxim Alexeev
Maxim Alexeev
PAPietro Antonioli
Pietro Antonioli
CBCasimiro Baldanza
Casimiro Baldanza
SVSimone Vallarino
Simone Vallarino
The ePIC experiment at the future Electron-Ion Collider (EIC) aims to use silicon photomultipliers (SiPMs) as the photodetector technology for the dual-radiator ring-imaging Cherenkov detector (dRICH). Despite their advantages for this low light application and insensitivity to high magnetic fields, SiPMs are sensitive to radiation and require rigorous testing to ensure that their single-photon counting capabilities and dark count rate are kept under control over the years of operation. The presented results show the successful use of a complete prototype readout chain based on the ALCOR chip for SiPM characterization measurements and assembled in an optical plane for test-beam measurements using the dRICH prototype.

1 February 2016 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
PDF file
SFSergio Fabiani
Sergio Fabiani
MAM Ahangarianabhari
M Ahangarianabhari
GBG Baldazzi
G Baldazzi
PBP Bellutti
P Bellutti
GBGiuseppe Bertuccio
Giuseppe Bertuccio
NZNicola Zorzi
Nicola Zorzi
The XAFS beamline at Elettra Synchrotron in Trieste combines X-ray absorption spectroscopy and X-ray diffraction to provide chemically specific structural information of materials. It operates in the energy range 2.4-27 keV by using a silicon double reflection Bragg monochromator. The fluorescence measurement is performed in place of the absorption spectroscopy when the sample transparency is too low for transmission measurements or the element to study is too diluted in the sample. We report on the development and on the preliminary tests of a new prototype detector based on Silicon Drift Detectors technology and the SIRIO ultra low noise front-end ASIC. The new system will be able to reduce drastically the time needed to perform fluorescence measurements, while keeping a short dead time and maintaining an adequate energy resolution to perform spectroscopy. The custom-made silicon sensor and the electronics are designed specifically for the beamline requirements.

1 August 2025 in Journal of Instrumentation
Verified
Journal Article
Open access
PDF file
BAB Rajesh Achari
B Rajesh Achari
NAN. Agrawal
N. Agrawal
MAM. Alexeev
M. Alexeev
CAC. Alice
C. Alice
PAP. Antonioli
P. Antonioli
RWR. Wheadon
R. Wheadon
The dual-radiator RICH (dRICH) detector of the ePIC experiment at the upcoming Electron-Ion Collider (EIC) will use silicon photomultipliers (SiPMs) for single-photon detection of Cherenkov light. Several novel INFN driven modular prototype photodetections units (PDUs) have been constructed, each integrating 256 SiPMs, cooling infrastructure and front-end electronics. To achieve a large area coverage, eight PDUs were assembled totalling 2048 readout channels; the full system was then tested at the CERN-PS T10 beamline. The system operated reliably under realistic conditions, and particle identification performance was validated over momenta ranging from 2 to 11 GeV/c using different radiator configurations. Complementary to the testing of sensor on the beam test lines, R&D is also ongoing to ensure consistent performance under radiation exposure. In-situ annealing methods using forward-bias heating have been developed to recover radiation damage of SiPMs. These techniques proved effective, with a recovery of radiation-induced damage up to 97–98% as observed in reducing the dark current. The effects of these procedure on the photo-detection efficiency of the sensors was also tested. Through repeated annealing cycles at different temperatures, a yellowing of the SiPM window has been noticed in the 175° batch, the origin of this effect is still under investigation.