This paper presents a wearable active concentric electrode chip for a concurrent EEG monitoring and a Body-Coupled Communication (BCC) data transmission. A 3-layer concentric electrode eliminates the wires. A common mode averaging unit (CMAU) is proposed to cancel not only the continuous common-mode interference (CMI) but also the instantaneous CMI of up to 51Vpp. The localized potential matching technique removes the ground electrode. An open-loop programmable gain amplifier (OPPGA) with the pseudo-resistor-based RC-divider block is presented to save the silicon area. The presented work is the first reported so far to achieve the concurrent EEG signal recording and BCC-based data transmission. The proposed chip achieves 100 dB CMRR and 110 dB PSRR, occupies 0.044 mm2, and consumes 7.4 μW with an input-referred noise density of 26 nV/ ${\sqrt{Hz}}$ .
25 October 2023 in IEEE Transactions on Biomedical Circuits and Systems
Epilepsy tracking System-on-Chips (SoC) usually perform patient-specific classification to deal with the patient-to-patient seizure pattern variation from a surface electroencephalogram (EEG). However, the patient-specific classifier training requires the EEG signals from the target patients a priori, which involves costly and time-consuming hospitalization for the inpatient data collection. To address this issue, this paper presents a patient-independent epilepsy tracking SoC that is trained with pre-existing databases and can be directly deployed to the target patients without collecting their data and performing cumbersome patient-specific training beforehand. The proposed SoC adopts a Seizure-Cluster-Inception Convolutional Neural Network (SciCNN) Neural Processor (SNP) to reduce SRAM access rate by 179.05× with the Kernel-Wise Pipeline (KWP). The 22-Ch. SoC achieves event-based sensitivity of 90.3%/90.4%/83.3% and specificity of 93.6%/95.7%/88.6% on unseen patients from CHB-MIT database/EU database/local hospital patient, respectively.
12 April 2022 in IEEE Transactions on Biomedical Circuits and Systems
An 8-channel AFE with a group-chopping instrumentation amplifier (GCIA) is proposed for bio-potential recording applications. The group-chopping technique cascades chopper switches to progressively swap channels and dynamically removes gain mismatch among all channels. An 8-phase non-overlapping clocking scheme is developed and achieves excellent between-channel gain mismatch characteristics. The dynamic offsets among all channels are mitigated by the GCIA as well. The GCIA is the first work that minimizes the gain mismatch across more than two channels. With the help of the group-chopping, combined with an area-efficient open-loop structure, the GCIA shows <0.04% between-channel gain mismatch, the lowest mismatch reported to date. The chip is fabricated in 0.18µm 1P6M CMOS, occupies only 0.017 mm 2 /Ch., consumes 2.1 μW/Ch. under 0.5 V supply and achieves an NEF of 2.1.
21 May 2024 in IEEE Transactions on Circuits and Systems I: Regular Papers
Capacitively-Coupled Instrumentation Amplifiers (CCIAs) are widely used as AC-coupled, low-noise amplifiers in many multi-channel, area-intensive sensor interface applications. However, the need for a trade-off between the front-end gain and CCIA area, imposed by the input capacitance, restricts the miniaturization of such sensors. We propose a Complementary Transimpedance Boosting (CTB) technique to relieve this challenging gain versus area trade-off. The proposed CTB applies to both the DC and AC paths of a CCIA. CTB also reduces AC gain degradation, suppressing low-side gain peaking of the frequency response without significantly increasing input-referred noise. The Gain-Noise-Area Efficiency (GNA) and Gain-Power-Area Efficiency (GPA) factors are also introduced for holistic comparisons with other front-end amplifiers regarding noise, gain, and power consumption. CTB-based CCIAs (CTB-CCIA) are fabricated in 0.18 $\mu$ m CMOS, with the highest single-stage AC gain of 289 V/V achieved. Occupying only 0.011 mm $^{2}$ , a conventional CCIA with the same area will have 14.4 $\times$ less gain while requiring at least two stages. The CTB-CCIA has a competitive NEF of 4.92 within a signal bandwidth of 0.21 Hz – 8.7 kHz, suitable for multi-channel applications.
An Intrinsic Feedback Capacitor Instrumentation Amplifier (IFCIA) is presented for bio-potential recording and respiratory monitoring. Exploiting the intrinsic gate-to-drain capacitor to scale down input capacitor, combined with interdigitated MOM capacitors, the inverter-based instrumentation amplifier (IA) occupies smallest active area of 0.012 mm2 with 1.5 G Ω input impedance (> > 1G Ω up to 100 Hz) and 0.65 μ A current consumption, while maintaining die-to-die gain mismatch of 0.41%.
31 August 2022 in The Academic Society of Global Business Administration
Profiting from product innovation is important for firm success. However, factors affecting the link between product innovation and firm performance is still unclear according to the previous empirical findings. Therefore, the purpose of this study is to introduce internal relation-based contingency of firm's linkage capability and external environment based contingency of market turbulence to analyze their moderating effect on the relationship between product innovation and firm performance. The empirical analysis is conducted with the survey data collected from 196 firms in Jilin province of China. The findings show that firm's close linkage capability with customers, suppliers, competitors and other firms within the same industry positively moderates the relationship between product innovation and firm performance while external market turbulence negatively moderates the relationship between product innovation and firm performance. The results implicate, in order to maximize the positive influence of product innovation on firm performance, firms should continuously exploit social capital and monitor external environment.