Luiza Streck

Luiza Streck

Auto-generated profile, based on publicly available information

Luiza Streck

Department of Energy and Process Engineering, Technical University of Munich, Arcisstr. 21, 80333, Munich, Germany, Munchen, Bayern, 80333, GERMANY

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2023 in Journal of the Electrochemical Society
Verified
Journal Article
Open access
PDF file
TRThomas Roth
Thomas Roth
LSLuiza Streck
Luiza Streck
AGAndreas Graule
Andreas Graule
PNPhilipp Niehoff
Philipp Niehoff
Andreas JossenAndreas Jossen
Andreas Jossen
In order to determine the quality of newly produced lithium-ion cells, self-discharge measurements are performed after manufacturing during the so-called aging step. The aging step is a time-consuming and cost-intensive process due to relaxation effects disturbing the self-discharge measuremtens. Relaxation effects are mainly attributed to voltage relaxation and anode overhang equalization. In this work, different methods for electrical self-discharge measurement, such as the voltage decay method, the voltage hold method, and the capacity loss method, were investigated using commercial Samsung INR21700–50E cylindrical cells (NCA/silicon-graphite) and non-commercial pouch-cells (NMC622/graphite). Various preconditioning methods allowed a distinction to be made between undisturbed, short-term, and long-term disturbed cells. While short-term disturbances subsided after several hours, long-term disturbances due to anode overhang were found to significantly disturb all electrical self-discharge measurements for several weeks. A theoretical explanation was introduced, describing the lithium inventory change due to anode and coupled side reactions being measured differently by voltage- and capacity-based methods. Experimental results confirmed this notion and showed that voltage-based self-discharge measurements underestimated the anode overhang equalization. A comparison to the initial cell aging data indicated that the self-discharge measurement performed shortly after cell formation was disturbed by the anode overhang equalization.

1 August 2024 in Journal of the Electrochemical Society
Verified
Journal Article
Open access
PDF file
LSLuiza Streck
Luiza Streck
TRThomas Roth
Thomas Roth
HBHannah Bosch
Hannah Bosch
CKCedric Kirst
Cedric Kirst
MRMathias Rehm
Mathias Rehm
Andreas JossenAndreas Jossen
Andreas Jossen
The calendar aging and self-discharge behavior of Na-Ion cells containing a layered oxide NaNi1/3Fe1/3Mn1/3 (NFM) cathode were investigated and compared to two Li-Ion cell chemistries, G/LiFePO4 (LFP) and SiG/LiNi0.8Mn0.1Co0.1O2 (NMC811). The self-discharge measurements were performed via voltage hold experiments at different states of charge (10%, 40%, 50%, 70%, 90%, and 100%) and temperatures (25 °C, 40 °C and 55 °C). A high-precision coulometry analysis was conducted to investigate the coulombic efficiency (CE), differential voltage analysis (DVA), and end-point slippage. The results show that the Na-Ion cells present a similar self-discharge behavior to the NMC811 Li-Ion cells. In addition, via CE and end-point slippage analysis, strong reversible reactions were observed for the Na-Ion cells. Despite the poor CE values, the cells presented a low capacity loss. Post-mortem analysis showed sodium plating on the edges of all the SOCs investigated. The LFP results presented mainly calendar losses from lithium inventory loss with almost no cathode-related degradation. At high SOCs, both transition metal cathodes, NMC811 Li-Ion and NFM Na-Ion, exhibited more cathode-related processes dominating the self-discharge current and presumably improving the capacity retention due to electrolyte oxidation. Finally, the Na-Ion cells showed anode overhang equalization effects like Li-Ion cells.

1 April 2023 in Journal of the Electrochemical Society
Verified
Journal Article
Open access
PDF file
LSLuiza Streck
Luiza Streck
TRThomas Roth
Thomas Roth
PKPeter Keil
Peter Keil
BSBenjamin Strehle
Benjamin Strehle
SLSeverin Ludmann
Severin Ludmann
Andreas JossenAndreas Jossen
Andreas Jossen
This study conducts a qualitative comparison between two methods for detecting side reactions - the voltage hold and voltage decay methods using a high precision coulometry (HPC) tester. The measurements were conducted with Si-G/NMC811 commercial cells for three different temperatures and four different states of charge (SoC) in order to determine the voltage and the temperature dependency of side reactions. Here, we show that the voltage hold and the voltage decay methods deliver comparable results when determining the differential capacity with an incremental capacity analysis (ICA) instead of a single pulse for the voltage decay method. Both methods presented a good agreement for high temperatures and high SoC cases. Only at 90% SoC was there a discrepancy of 15% on the leakage capacities, which was attributed to the peak shape of the ICA curve. Therefore, it was found advantageous to analyse the ICA shape of the respective cells when performing such measurements. In addition, with the end of charge point and end of discharge point slippage evaluation, it was possible to observe that couple side reactions dominate the leakage currents at higher SoCs and lead to reversible losses. The irreversible losses remain almost constant for SoCs higher than 50%.

1 August 2023 in Journal of the Electrochemical Society
Verified
Journal Article
Open access
TRThomas Roth
Thomas Roth
LSLuiza Streck
Luiza Streck
NMNedim Mujanovic
Nedim Mujanovic
MWMartin Winter
Martin Winter
PNPhilip Niehoff
Philip Niehoff
Andreas JossenAndreas Jossen
Andreas Jossen
A fast determination of cell quality after formation is challenging due to transient effects in the self-discharge measurement. This work investigated the self-discharge of NMC622/graphite single-layer pouch cells with varying anode dimensions to differentiate between SEI growth and anode overhang equalization processes. The transient self-discharge was measured directly after formation via voltage decay and for 20 weeks of calendar storage at three states-of-charge (SOC), 10%, 30%, and 50%. The transient behavior persisted for the entire measurement duration, even at a low SOC. Still, the low SOC minimized the impact of SEI growth and anode overhang equalization compared to moderate SOCs. Evaluating the coulombic efficiency from cycle aging showed a distinct capacity loss for the first cycle after storage, indicating further SEI growth, which stabilized in subsequent cycles. The aged capacity after cycling showed no significant dependence on the calendar storage, which further promotes fast self-discharge characterization at low SOC.

1 October 2023 in Journal of the Electrochemical Society
Verified
Journal Article
Open access
EMErfan Moyassari
Erfan Moyassari
ZLZheng Li
Zheng Li
BTBenedikt Tepe
Benedikt Tepe
LSLuiza Streck
Luiza Streck
Andreas JossenAndreas Jossen
Andreas Jossen
Understanding the cyclic behavior of Lithium-Ion Batteries (LIBs) is crucial for optimizing their performance and extending their operational lifespan. This work presents a study on the cycle characterization of silicon-oxide-based (SiOx) cells, focusing on the impact of real load profiles and state-of-charge (SoC) ranges while varying the SiOx content in the cells. Various load profiles representing real usage patterns obtained from an industrial partner were applied to SiO-based pouch cells. These load profiles are represented over different SoC ranges to explore the effect of varying levels of charge/discharge on battery aging. The aging characteristics of the batteries are evaluated by monitoring capacity fade, state-of-health (SoH), and capacity end-point-slippage. The experimental results demonstrate that the different SiOx content of the investigated cells and the SoC range significantly influence the cycle behavior of the cells. The resulting capacity loss was affected especially by the anode overhang effect. Cycling under high SoC conditions accelerates capacity fade and leads to higher SoH loss. The findings also indicate that SiO-based cells exhibited higher aging than traditional graphite-based cells. The capacity fade rate increased at higher SiOx content.

1 June 2025 in Journal of the Electrochemical Society
Verified
Journal Article
Open access
PDF file
QYQing Yu
Qing Yu
IKIqra Kiran
Iqra Kiran
MEMoritz Ehrensberger
Moritz Ehrensberger
LSLuiza Streck
Luiza Streck
TRThomas Roth
Thomas Roth
MLMeinert Lewerenz
Meinert Lewerenz
Analyzing calendar aging by float current analysis, instead of solely repeating capacity tests, gains more insights into aging. However, the underlying mechanisms of the recharge current required to keep the voltage constant are not yet fully understood. Therefore, this study performs float current and additional open circuit voltage (OCV) tests on 3-electrode cells for four different voltages at 30 °C. By monitoring the potentials of the anode and the cathode over time individually, the aging rate on both electrodes and the present capacity can be calculated based on adjusting the electrode-specific OCV curves according to the voltage slippery theory. The electrode-specific aging and the capacity prediction show high agreement among both methods and the capacity tests at the end of the experiment. As a result, the capacity loss appears linear-like and is associated with the loss of active lithium mainly due to SEI formation on the anode. Additionally, a significant cathode voltage decay is observed especially for higher cell voltage. According to the literature, this is associated with cathode lithiation where the conductive salt is decomposed by inserting active lithium into the cathode masking SEI losses. Finally, OCV and float current analysis return comparable results and support present 2-electrode evaluation approaches.