Zakaria Hussain

Zakaria Hussain

Auto-generated profile, based on publicly available information

Zakaria Hussain

Universiti Teknologi MARA Cawangan Pulau Pinang, Universiti in Permatang Pauh

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2016
Verified
Conference Paper
Closed access
AOAzizul Othman
Azizul Othman
NHNorhazimi Hamzah
Norhazimi Hamzah
ZHZakaria Hussain
Zakaria Hussain
RBRohaiza Baharudin
Rohaiza Baharudin
ARAnis Diyana Rosli
Anis Diyana Rosli
AAAdi Izhar Che Ani
Adi Izhar Che Ani
In this paper, an adjustable angle sensor based on rotary potentiometer for measuring and monitoring finger flexion is proposed. Most of the current system is unadjustable, inaccurate, costly and hard to calibrate. The proposed system in this study consists of a rotary potentiometers and adjustable case, which makes it adjustable, compact and lightweight with the ability to produce a better measurement result. As the rotary potentiometer rotated due to the motion of the finger, the joint angles are calculated by measuring the change in resistance of the rotary potentiometer. The proposed system can widely be applied for the angle measurement systems at small and complex structure surface such as finger joint, which require to measure finger flexion for developing related device such as robotic hand control system, virtual reality or teleoperation systems. The experiment study shows that the proposed system is adjustable and has better accuracy, small repeatability error and more reliable compared to the popular flex sensor.

16 August 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
ENEMILIA NOORSAL
EMILIA NOORSAL
SASaharul Arof
Saharul Arof
SYSaiful Zaimy Yahaya
Saiful Zaimy Yahaya
ZHZakaria Hussain
Zakaria Hussain
DKDaniel Kho
Daniel Kho
YAYusnita Mohd Ali
Yusnita Mohd Ali
Functional electrical stimulation (FES) device has been widely used by spinal cord injury (SCI) patients in their rehab exercises to restore motor function to their paralysed muscles. The major challenge of muscle contraction induced by FES is early muscle fatigue due to the open-loop stimulation strategy. To reduce the early muscle fatigue phenomenon, a closed-loop FES system is proposed to track the angle of the limb’s movement and provide an accurate amount of charge according to the desired reference angle. Among the existing feedback controllers, fuzzy logic controller (FLC) has been found to exhibit good control performance in handling complex non-linear systems without developing any complex mathematical model. Recently, there has been considerable interest in the implementation of FLC in hardware embedded systems. Therefore, in this paper, a digital fuzzy feedback controller (FFC) embedded in a field-programmable gate array (FPGA) board was proposed. The digital FFC mainly consists of an analog-to-digital converter (ADC) Data Acquisition and FLC sub-modules. The FFC was designed to monitor and control the progress of knee extension movement by regulating the stimulus pulse width duration to meet the target angle. The knee is expected to extend to a maximum reference angle setting (70°, 40° or 30°) from its normal position of 0° once the stimulus charge is applied to the muscle by the FES device. Initially, the FLC was modelled using MATLAB Simulink. Then, the FLC was hardcoded into digital logic using hardware description language (HDL) Verilog codes. Thereafter, the performance of the digital FLC was tested with a knee extension model using the HDL co-simulation technique in MATLAB Simulink. Finally, for real-time verification, the designed digital FFC was downloaded to the Intel FPGA (DE2-115) board. The digital FFC utilized only 4% of the total FPGA (Cyclone IV E) logic elements (LEs) and required 238 µs to regulate stimulus pulse width data, including 3 µs for the FLC computation. The high processing speed of the digital FFC enables the stimulus pulse width duration to be updated every stimulation cycle. Furthermore, the implemented digital FFC has demonstrated good control performance in accurately controlling the stimulus pulse width duration to reach the desired reference angle with very small overshoot (1.4°) and steady-state error (0.4°). These promising results are very useful for a real-world closed-loop FES application.

12 July 2023 in Machines
Verified
Journal Article
Open access
PDF file
SASaharul Arof
Saharul Arof
ENEMILIA NOORSAL
EMILIA NOORSAL
SYSaiful Zaimy Yahaya
Saiful Zaimy Yahaya
ZHZakaria Hussain
Zakaria Hussain
YAYusnita Mohd Ali
Yusnita Mohd Ali
MSMuhamad Khuzzairie Safie
Muhamad Khuzzairie Safie
Functional electrical stimulation (FES) has been widely used to treat spinal cord injury (SCI) patients. Many research studies employ a closed-loop FES system to monitor the stimulated muscle response and provide a precise amount of charge to the muscle. However, most closed-loop FES devices perform poorly and sometimes fail when muscle nonlinearity effects such as fatigue, time delay response, stiffness, spasticity, and subject change happen. The poor performance of the closed-loop FES device is mainly due to discrepancies in the feedback control algorithms. Most of the existing feedback control algorithms were not designed to adapt to new changes in patients with different nonlinearity effects, resulting in early muscle fatigue. Therefore, this research proposes an adaptive sliding mode (SM) feedback control algorithm that could adapt and fine-tune internal control settings in real-time according to the current subject’s nonlinear and time-varying muscle response during the rehabilitation (knee extension) exercise. The adaptive SM feedback controller consists mainly of system identification, direct torque control, and tunable feedback control settings. Employing the system identification unit in the feedback control algorithm enables real-time self-tuning and adjusting of the SM internal control settings according to the current patient’s condition. Initially, the patient’s knee trajectory response was identified by extracting meaningful information, which included time delay, rise time, overshoot, and steady-state error. The extracted information was used to fine-tune and update the internal SM control settings. Finally, the performance of the proposed adaptive SM feedback control algorithm in terms of system response time, stability, and rehabilitation time was analysed using a nonlinear knee model. The findings from the simulation results indicate that the adaptive SM feedback controller demonstrated the best control performance in accurately tracking the desired knee angle movement by having faster response times, smaller overshoots, and lower steady-state errors when compared with the conventional SM across four reference angle settings (20°, 30°, 40°, and 76°). The adaptive feedback SM controller was also observed to compensate for muscle nonlinearities, including fatigue, stiffness, spasticity, time delay, and other disturbances.

1 December 2016
Verified
Conference Paper
Closed access
MRMohamad Faizal Abd Rahman
Mohamad Faizal Abd Rahman
AAA.I.C. Ani
A.I.C. Ani
SYS.Z. Yahaya
S.Z. Yahaya
ZHZ. Hussain
Z. Hussain
RBR. Boudville
R. Boudville
AAA. Ahmad
A. Ahmad
This paper proposed a new teaching technique for engineering courses based on the implementation of drone technology. In some engineering related courses, teaching and learning are difficult due to very complex theoretical and technical explanation need to be digested by the non experienced students. In Malaysia, quadcopter is one of the technologies that become popular among young generation due to its capabilities and interesting features in various application such as aerial photography, aerial monitoring as well as aerial racing tournament. The use of quadcopter thought to be one of the best ways to introduce some engineering concept through a practical exposure followed by project based learning. The concept is able to enhance the understanding as students are exposed to a practical and visual approach used during the learning process. The outcomes shows that once the student gain confidence in building the drone unit, they are ready to explore more on the engineering disciplines through the process. Open source flight software, Mission Planner, is used to configure every components used in the development.

1 June 2024 in Indonesian Journal of Electrical Engineering and Computer Science
Verified
Journal Article
Open access
PDF file
SASaharul Arof
Saharul Arof
ENEMILIA NOORSAL
EMILIA NOORSAL
SYSaiful Zaimy Yahaya
Saiful Zaimy Yahaya
ZHZakaria Hussain
Zakaria Hussain
RRRosfariza Radzali
Rosfariza Radzali
HMHarith Firdaus Mustapha
Harith Firdaus Mustapha
Functional electrical stimulation (FES) has shown potential in rehabilitative exercises for patients recovering from spinal cord injuries. In recent developments, conventional open-loop FES control techniques have evolved into closed-loop systems that employ feedback controllers for automation. However, closed-loop FES systems often face challenges due to muscle non-linear effects, such as fatigue, time delays, stiffness, and spasticity. Therefore, an accurate non-linear knee model is required during the design stage, and precise tuning of the feedback controller parameters is vital. A proportional– integral–derivative (PID) controller is commonly used as a feedback controller due to its simplicity and ease of implementation. However, most PID tuning methods are complex and time consuming. This paper investigates the viability of employing the pole placement technique for tuning a PID controller that regulates the non-linear knee extension model. The pole placement method aims to improve the control and adaptability of the PID controller in closed-loop FES systems, specifically by facilitating knee extension exercises. MATLAB Simulink was used to assess the effectiveness of this tuning approach. Results showed that the PID controller performed satisfactorily without non-linearities, but performance varied with the inclusion of specific non-linearities. The pole placement tuning method facilitated preliminary assessments of PID controller performance, preceding highly advanced optimization.

1 June 2013
Verified
Conference Paper
Closed access
ZHZakaria Hussain
Zakaria Hussain
RBRozan Boudville
Rozan Boudville
SYSaiful Zaimy Yahaya
Saiful Zaimy Yahaya
FAFadzil Ahmad
Fadzil Ahmad
This work is focused on the development of physiological and mathematical model of muscle extension induced by FES-assisted knee swinging ergometer. A muscle model composed of muscle activation, muscle contraction and body segmental dynamics is developed to perform full knee extension. The developed muscle model is then incorporated with a humanoid model and a knee swinging ergometer model to perform simulation of FES-assisted knee swinging exercise. The developed humanoid model possesses the characteristics of stroke patient while the knee swinging ergometer was developed with the ability of utilizing the non-paretic knee in assisting the swinging of the paretic knee. The developed muscle model is evaluated under the dynamic simulation of FES-assisted knee swinging ergometer. The active torque and knee trajectories are recorded and the results shows that the design of knee swinging ergometer had successfully reduced the required stimulation pulse width in performing full knee extension. It is also suggested that the muscle model developed can be used for future analysis and control development of FES-assisted knee swinging ergometer for stroke patient.