Jianbang Niu

Jianbang Niu

Auto-generated profile, based on publicly available information

Jianbang Niu

School of Electrical Engineering, Southwest Jiaotong University, Chengdu, China

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 October 2023 in IEEE Transactions on Transportation Electrification
Verified
Journal Article
Closed access
Wei LiuWei Liu
Wei Liu
ZPZhe Pan
Zhe Pan
YTYuning Tang
Yuning Tang
LZLinjie Zhou
Linjie Zhou
ABAshfaque Ahmed Bhatti
Ashfaque Ahmed Bhatti
JNJianbang Niu
Jianbang Niu
Stray current in the DC metro system is commonly assessed using circuit or electric field models. Circuit models cannot accurately represent the stray current diffusion due to the track bed and soil resistivity effect on rail-to-earth resistance (RE). Meanwhile, electric field models lack detailed device modeling, which hampers their ability to comprehensive stray current analyses. To overcome these limitations, a field-circuit coupling diffusion model for stray current is proposed. The electric field submodel is established through the direct boundary element method (DBEM) for the metro reflux system (RS) and obtaining the mutual resistance matrix. The circuit submodel of the DC traction power system (DPS) is established based on the behavior characteristics of the RS devices. The dynamic stray current diffusion is obtained by coupling the two submodels through the mutual resistance matrix. The accuracy and efficiency in solving large systems with massive textures of the proposed model are verified by comparing them with the field test data and other existing methods. The case shows that strengthening the RE for a length of 500-meter on both sides of each traction power substation (TPS) can effectively reduce the earth potential gradient along the metro line.

12 August 2024 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
LZLinjie Zhou
Linjie Zhou
Wei LiuWei Liu
Wei Liu
ZPZhe Pan
Zhe Pan
YTYuning Tang
Yuning Tang
SLSongyuan Li
Songyuan Li
JNJianbang Niu
Jianbang Niu
Currently, the impact of stray current is worsening. To control stray current and rail potential, over voltage protection device (OVPD), connection device (CD), and other equipment are widely used in metro. State transitions of the return system equipment cause dynamic changes in rail potentials, and together with changes in the surrounding heterogeneous soil structure, both directly affect the distribution of stray currents. Therefore, this paper proposes a method for calculating stray current and rail potential based on fast adaptive direct boundary element (FADBE), which takes into account the behavior process of reflux current equipment and surrounding geographical environment. FADBE not only greatly reduces iteration time, but also adaptively modifies parameters of reflux system. Through field experiments, the error in the calculation of FADBE is controlled within 6.87%. An authentic metro project is simulated and the results obtained from FADBE are found to be more consistent with the changes in rail potential and ground potential gradient observed. The results show that Different connections between the station and the main line can cause the surrounding ground potential gradient to vary by more than 43.47%. DC disturbances on metro lines near rivers and oceans should receive more attention.

18 March 2025 in IEEE Transactions on Reliability
Verified
Journal Article
Closed access
Wei LiuWei Liu
Wei Liu
FLFeilong Liu
Feilong Liu
ZPZhe Pan
Zhe Pan
ZYZhuoxin Yang
Zhuoxin Yang
JNJianbang Niu
Jianbang Niu
The problem of dc interference caused by stray currents in dc traction power supply system (DPS) is becoming increasingly serious. In order to study the interference degree of stray currents, a unified model of DPS and stray current dissipation based on the direct boundary element method (UBEM) has been established. The stray current collection network (SCCN) polarization potential is an important index to evaluate the leakage level of stray current. In this article, the relationship between SCCN polarization potential and rail-to-earth resistance (RE), train headways and longitudinal resistance of SCCN is investigated. It provides a partial theoretical basis and calculation method for stray current protection and system optimization. Field tests and CDEGS software simulations prove that UBEM is effective. The results show that UBEM is within 6.07% of the CDEGS simulation results and within 11.45% of the field test results. Taking the actual metro project in China as an example, SCCN polarization potential is only affected by local stray current. When RE>7.35 Ω·km, The average value of the SCCN polarization potential drops below 0.5 V.