Ashfaque Ahmed Bhatti

Ashfaque Ahmed Bhatti

Auto-generated profile, based on publicly available information

Ashfaque Ahmed Bhatti

School of Electrical Engineering, Southwest Jiaotong University, Chengdu, China

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 December 2024 in IEEE Transactions on Transportation Electrification
Verified
Journal Article
Closed access
QXQian Jiaotong Xu
Qian Jiaotong Xu
Wei LiuWei Liu
Wei Liu
JDJuxia Ding
Juxia Ding
ZTZhongbei Tian
Zhongbei Tian
JZJian Zhang
Jian Zhang
ABAshfaque Ahmed Bhatti
Ashfaque Ahmed Bhatti
The system efficiency of reversible substations (RSSs) in urban rail transit power supply systems has garnered significant attention. In particular, reverse power flow from the main substation (MS) has been observed in the real world, adversely impacting system efficiency. This article proposes a novel power supply structure for RSSs that effectively reduces reverse power flow. To further enhance system efficiency, an optimal model is established by leveraging the control characteristics of RSSs. Then, a system efficiency energy regulation and control framework considering complex scenarios is presented, with the lowest system losses as the optimization objective. The modified Cheetah Optimizer algorithm is adopted to optimize the control parameters of reversible converters (RCs). Simulations of actual engineering cases are conducted, and the results demonstrate the effectiveness of the proposed power supply solution and energy regulation control in various scenarios. The proposed method can improve energy efficiency by up to 3.25% and 2% compared with nonoptimized and existing offline optimized methods, and this value varies depending on the scenario. Additionally, performance analysis and evaluation highlight the fundamentals of energy regulation in enhancing system efficiency, including balancing bus load, appropriately increasing catenary voltage, and adjusting the proportion of regenerative braking energy (RBE) between the ac and dc sides based on different situations.

26 October 2023 in IEEE Transactions on Transportation Electrification
Verified
Journal Article
Closed access
Wei LiuWei Liu
Wei Liu
ZPZhe Pan
Zhe Pan
YTYuning Tang
Yuning Tang
LZLinjie Zhou
Linjie Zhou
ABAshfaque Ahmed Bhatti
Ashfaque Ahmed Bhatti
JNJianbang Niu
Jianbang Niu
Stray current in the DC metro system is commonly assessed using circuit or electric field models. Circuit models cannot accurately represent the stray current diffusion due to the track bed and soil resistivity effect on rail-to-earth resistance (RE). Meanwhile, electric field models lack detailed device modeling, which hampers their ability to comprehensive stray current analyses. To overcome these limitations, a field-circuit coupling diffusion model for stray current is proposed. The electric field submodel is established through the direct boundary element method (DBEM) for the metro reflux system (RS) and obtaining the mutual resistance matrix. The circuit submodel of the DC traction power system (DPS) is established based on the behavior characteristics of the RS devices. The dynamic stray current diffusion is obtained by coupling the two submodels through the mutual resistance matrix. The accuracy and efficiency in solving large systems with massive textures of the proposed model are verified by comparing them with the field test data and other existing methods. The case shows that strengthening the RE for a length of 500-meter on both sides of each traction power substation (TPS) can effectively reduce the earth potential gradient along the metro line.

27 January 2025 in IEEE Transactions on Transportation Electrification
Verified
Journal Article
Closed access
ABAshfaque Ahmed Bhatti
Ashfaque Ahmed Bhatti
Wei LiuWei Liu
Wei Liu
MLMingze Li
Mingze Li
QMQingan Ma
Qingan Ma
QXQian Jiaotong Xu
Qian Jiaotong Xu
XZXiaodong Zhang
Xiaodong Zhang
In dual-traction power supply system (DTPSS), an improper value of onboard grounding resistance could result in a larger current distribution, axle end potential, and surge over-voltage (SOV) of the vehicle body (VB) because of the interaction between the AC and DC traction power supply system and the train crossing the neutral sections. Therefore, it is important to carefully select the appropriate value of the resistance and position of the grounding points. This research article proposed the steady-state model of DTPSS to evaluate the current distribution and axle-end potential, and the transient state model of DTPSS to calculate the SOV of the VB of vehicle grounding systems (VGS). To obtain the best optimal solution, the particle swarm optimization (PSO) and the technique for order of preference by similarity to ideal solution (TOPSIS) multi-objective optimization techniques have been implemented. The accuracy and efficiency of the VB current distribution are verified by observing the experimental and simulation results. The proposed VGS optimization technique demonstrates that the VB current distribution has achieved a significant improvement of 24.8% of the total current in the DC section and 21.1% of the total current in the AC section. By observing experimental, simulation, and optimal solutions of transient models in DTPSS, the SOV value was reduce to 33.4% of the total voltage.

1 December 2019
Verified
Conference Paper
Closed access
HLHongdong Lin
Hongdong Lin
YWYijiang Wu
Yijiang Wu
GWGanjun Wang
Ganjun Wang
WLWenze Li
Wenze Li
XPXiaosheng Peng
Xiaosheng Peng
ABAshfaque Ahmed Bhatti
Ashfaque Ahmed Bhatti
Partial Discharge (PD) signal is an important parameter reflecting the insulation condition of High Voltage(HV) cables. Meanwhile, PD detection and monitoring is an effective way to ensure the safe and stable operation of the HV cables. Due to the limited bandwidth and the poor anti-interference ability of the current PD sensors, there are a lot of interference signals in the detected PD signals. To overcome the challenge, a novel built-in metal foil sensor for PD detection of HV cables is presented in the paper. The influencing factors of the PD detecting sensitivity, which are the single electrode and the two electrodes, the size of the electrodes, the shape of the single electrode and the distance between the two electrodes, are evaluated. The experimental data is accumulated to determine the parameters of the metal foil sensor. Experimental results show that the built-in metal foil sensor has excellent efficiency in PD signal reception in both laboratory and experimental base, which is applicable for on-line PD detecting of HV cables.