30 May 2019 in IEEE Sensors Letters
24 February 2020 in IEEE Sensors Journal
This paper presents a fully analog auto-nulling bridge based capacitance-to-voltage (AN-C2V) converter circuit for measuring the capacitive component of the leaky capacitive sensors. The circuit utilizes an active bridge based architecture in which the quadrature components of the output are taken. An integrator-controller is used for auto-nulling. A unity gain, frequency-independent quadrature phase shift amplifier is designed for an accurate generation of 90° phase-shifted signal. Experiments conducted on the developed prototype demonstrate that the proposed AN-C2V system is able to estimate the sensor capacitor ranging from 47.2pF to 668.3pF with a maximum error of about ± 0.18% with respect to the commercial LCR meter. The effectiveness of the circuit is tested with the commercial leaky capacitive humidity sensor. The effect of leakage resistor, parasitic capacitor, frequency of excitation signal, and supply voltage is negligible on the final output, which results in a very robust and accurate solution for leaky capacitive sensors.
6 March 2020 in IEEE Journal of Emerging and Selected Topics in Power Electronics
This paper discusses a novel RF energy harvesting system for available power as low as 500 nW. The system includes a main RF rectenna (antenna followed by rectifier) for energy harvesting, an auxiliary RF rectenna for power detection and a boost converter along with its control circuit. For maximum power point tracking (MPPT), a particular reference voltage Vref for a range of received RF power (–11 dBm to 3 dBm) is used to harvest maximum available power from the main rectenna by regulating its output voltage with the help of the boost converter. Vref for MPPT is provided by the auxiliary RF rectenna and power detector circuit and depends on the RF power. The complete system is designed, simulated, fabricated, and tested in 180 nm mixed-mode CMOS technology. Measured results show that the boost converter can track the maximum power point for the input available power ranging from 500 nW to 1 mW. The efficiency of the boost converter is a function of the available input power and the equivalent source resistance of the RF energy harvester. For an equivalent source resistance of 1 kΩ, the maximum efficiency of the boost converter is 91.6% at 165 μW of available input power. As a potential application, a Σ modulator designed in 180 nm mixed-mode CMOS technology is powered by the proposed energy harvesting system. The efficiency of the boost converter is approximately 76.6% while powering the Σ modulator, and 78.5% while powering the DC load at RF power of -7 dBm. Index terms– RF energy harvesting, rectenna, power management circuit, boost converter, MPPT, power-detector circuit, synchronous rectification, wireless sensor nodes, sustainable energy, energy storage.
1 November 2020 in IEEE Transactions on Instrumentation and Measurement
In this paper, we propose an anto-nulling based multi-mode impedance-to-voltage converter (AN-Z2V) signal conditioning circuit for resistive-capacitive (R-C) sensors. The proposed technique takes advantage of reuse of the phase tracking and auto-nulling modules to extract the in-phase and quadrature components of the sensors. The circuit is designed for three sensing modes: 1) Mode-C for capacitive sensors with leakage resistor, 2) Mode-R for resistive sensors with parasitic shunt capacitor, and 3) Mode-Z for impedance R-C sensor. A novel auto-tuning quadrature phase generator circuit is designed and implemented for the generation of reference 90° phase-shifted signal for the leaky capacitive sensors. A prototype of the proposed circuit is fabricated and tested. Measurement results show that AN-Z2V provides the measurement range with low relative error as compared to the reported systems. The system is tested for a range of 10 pF to 760 pF and 56 kΩ to 6.5 MΩ for mode-C and mode-R, respectively. The accuracy of the proposed circuit is found to be ±0.11% and ±0.07% for mode-C and mode-R, respectively. The capacitance and resistance of the impedance R-C sensor are simultaneously measured in mode-Z for a range of 33 pF to 528 pF and 100 kΩ to 7.8 MΩ, respectively.
16 October 2019 in IEEE Transactions on Circuits and Systems I: Regular Papers
30 July 2021 in IEEE Transactions on Instrumentation and Measurement
A robust signal conditioning circuit for capacitive sensors, based on the dual-slope and phase-sensitive-detection technique, is presented in this paper. The circuit is designed to measure the capacitance of the leaky capacitive sensors. The phase-sensitive-detection technique mitigates the effect of the shunting conductance. In addition, the circuit is designed in such a way that the error due to the parasitic/stray capacitance on the measurement of the sensor capacitance is negligible. Furthermore, an auto-tuning frequency-independent quadrature phase-shifter circuit is designed for an accurate 90° phase generation. A prototype of the circuit is built and tested. The experimental results show that the designed circuit can measure the sensor capacitance in the range from 65 pF to 528 pF with accuracy within ±1%. The robustness of the proposed circuit is tested against the variation in the amplitude and frequency of input sinusoidal excitation signal. The results confirm that the proposed circuit is well suited for sensors such as capacitive humidity sensors, water level detection sensors, fingerprint sensors, and so on.