Meraj Ahmad

Meraj Ahmad

Auto-generated profile, based on publicly available information

Meraj Ahmad

James Watt School of Engineering, University of Glasgow, Glasgow, U.K.

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 July 2020 in npj Flexible Electronics
Verified
Journal Article
Open access
PDF file
TTTrupti Terse-Thakoor
Trupti Terse-Thakoor
MPMeera Punjiya
Meera Punjiya
ZMZimple Matharu
Zimple Matharu
BLBoyang Lyu
Boyang Lyu
MAMeraj Ahmad
Meraj Ahmad
Sameer SonkusaleSameer Sonkusale
Sameer Sonkusale
Sensor platforms that exploit the fibrous textile threads as substrates offer great promise since they can be directly sewn, woven or stitched on to any clothing. They can also be placed directly in intimate contact with the skin. In this work, we present a thread-based sensing platform in the form of a multiplexed sensing patch for continuous simultaneous on-skin monitoring of sweat. The patch performs real-time, on-body measurements of important biomarkers present in sweat such as electrolytes (sodium and ammonium ions), metabolites (lactate) and acidity (pH). Flexible threads coated with conductive inks were used as sensing electrodes. Selective potentiometric detection of electrolytes and pH was made possible through ion-selective membrane deposition and pH-sensitive polyaniline coating on threads, respectively. An amperometric enzymatic sensing scheme with lactate oxidase was used for the detection of lactate. An array of the thread sensors is integrated onto a patch with connectivity to a miniaturized circuit module containing a potentiostat, microprocessor and wireless circuitry for wireless smartphone readout. Extensive in vitro validation and an in vivo human pilot study involving a maximal exertion test show the promise of this platform for real-time physiological monitoring of human performance/fitness under stress, as well as diagnostic monitoring through sweat analysis.

24 February 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
SMShahid Malik
Shahid Malik
LSLaxmeesha Somappa
Laxmeesha Somappa
MAMeraj Ahmad
Meraj Ahmad
MBMaryam Shojaei Baghini
Maryam Shojaei Baghini
This paper presents a fully analog auto-nulling bridge based capacitance-to-voltage (AN-C2V) converter circuit for measuring the capacitive component of the leaky capacitive sensors. The circuit utilizes an active bridge based architecture in which the quadrature components of the output are taken. An integrator-controller is used for auto-nulling. A unity gain, frequency-independent quadrature phase shift amplifier is designed for an accurate generation of 90° phase-shifted signal. Experiments conducted on the developed prototype demonstrate that the proposed AN-C2V system is able to estimate the sensor capacitor ranging from 47.2pF to 668.3pF with a maximum error of about ± 0.18% with respect to the commercial LCR meter. The effectiveness of the circuit is tested with the commercial leaky capacitive humidity sensor. The effect of leakage resistor, parasitic capacitor, frequency of excitation signal, and supply voltage is negligible on the final output, which results in a very robust and accurate solution for leaky capacitive sensors.

28 August 2020 in IEEE Journal of Solid-State Circuits
Verified
Journal Article
Closed access
MAMeraj Ahmad
Meraj Ahmad
SMShahid Malik
Shahid Malik
SDSourya Dewan
Sourya Dewan
Arnesh BoseArnesh Bose
Arnesh Bose
Dinesh MaddipatlaDinesh Maddipatla
Dinesh Maddipatla
MBMaryam Shojaei Baghini
Maryam Shojaei Baghini
Most of the resistive sensors have a large baseline resistor and a relatively small incremental change in the resistor value due to the measurand. A half-bridge-based versatile Δ R/Rₛ measurement system for a wide range of resistive sensors is reported in this article. A four-phase auto-calibration-based differential and ratiometric operation is used to compensate for the baseline resistance of the sensor and the mismatches due to the non-ideal circuit parameters. A low-noise application-specific current generator and low noise, high CMRR current-mode instrumentation amplifier is designed and fabricated in UMC 180-nm technology. A prototype board of the Δ R/Rₛ measurement system is developed and tested. The experimental results show that the proposed system is able to detect even smaller ppm level of about 72 ppm of Δ R/Rₛ for the base resistor Rₛ value as high as 0.5 MΩ with a relative error of less than ±1%. The effect of the parasitic capacitors on the sensor response is also tested experimentally. Finally, the proposed system is tested with an in-house fabricated displacement sensor.

1 November 2020 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
SMShahid Malik
Shahid Malik
MAMeraj Ahmad
Meraj Ahmad
LSLaxmeesha Somappa
Laxmeesha Somappa
Tarikul  IslamTarikul Islam
Tarikul Islam
MBMaryam Shojaei Baghini
Maryam Shojaei Baghini
In this paper, we propose an anto-nulling based multi-mode impedance-to-voltage converter (AN-Z2V) signal conditioning circuit for resistive-capacitive (R-C) sensors. The proposed technique takes advantage of reuse of the phase tracking and auto-nulling modules to extract the in-phase and quadrature components of the sensors. The circuit is designed for three sensing modes: 1) Mode-C for capacitive sensors with leakage resistor, 2) Mode-R for resistive sensors with parasitic shunt capacitor, and 3) Mode-Z for impedance R-C sensor. A novel auto-tuning quadrature phase generator circuit is designed and implemented for the generation of reference 90° phase-shifted signal for the leaky capacitive sensors. A prototype of the proposed circuit is fabricated and tested. Measurement results show that AN-Z2V provides the measurement range with low relative error as compared to the reported systems. The system is tested for a range of 10 pF to 760 pF and 56 kΩ to 6.5 MΩ for mode-C and mode-R, respectively. The accuracy of the proposed circuit is found to be ±0.11% and ±0.07% for mode-C and mode-R, respectively. The capacitance and resistance of the impedance R-C sensor are simultaneously measured in mode-Z for a range of 33 pF to 528 pF and 100 kΩ to 7.8 MΩ, respectively.

1 December 2025 in APL Quantum
Verified
Journal Article
Open access
JBJack C. Brennan
Jack C. Brennan
JBJoão Barbosa
João Barbosa
CLChong Li
Chong Li
MAMeraj Ahmad
Meraj Ahmad
FIFiheon Imroze
Fiheon Imroze
MWMartin Weides
Martin Weides
Quantum processors have the potential to revolutionize computing on a scale unseen since the development of semiconductor technology in the middle of the twentieth century. However, while there is now huge activity and investment in the field, there are a number of challenges that must be overcome before the technology can be fully realized. Of primary concern is the development of the classical technology required to interface with quantum systems, as we push toward a new era of high-performance, large-scale quantum computing. In this review, we briefly discuss some of the main challenges facing the development of universally useful quantum computers and the different architectures being investigated. We are primarily concerned with cryogenic quantum systems. These systems are among the most mature quantum computing architectures to date and are garnering a lot of both industrial and academic attention. We present and analyze the leading methods of interfacing with quantum processors, both now and for the next generation of larger, multi-qubit systems. Recent advancements in control cryoelectronics, both semiconducting and superconducting, are covered, while a view toward newer methods such as optical and wireless qubit interfaces is also presented.

8 December 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
MAMeraj Ahmad
Meraj Ahmad
SMShahid Malik
Shahid Malik
HPHarsh Patel
Harsh Patel
MBMaryam Shojaei Baghini
Maryam Shojaei Baghini
Objective: The objective of the paper is to present a novel systematic approach for the design and development of a portable, low-voltage low-power resistive sensor measurement system with high sensitivity. The goal of the proposed system is to be able to measure the ΔR/Rs for a wide range of baseline resistance of sensor Rs (1 kΩ to 1 MΩ i.e. 3 orders of magnitude) with high resolution and programmable sensitivity. Method: An auto-calibrated resistive sensor interface using a novel half-bridge based circuit is presented. The square-wave excitation and square-wave demodulation technique are utilised to reduce the power consumption of the proposed technique. Moreover, the sensitivity of the system is fully auto-calibrated for a wide range of base resistors. Results: With a supply voltage of 3.3 V and bandwidth of 10 Hz, the developed system is able to measure a minimum ΔR/Rs of about 20 ppm for 100 kΩ base resistance. Overall, the power consumption of the developed system is 36.3 mW (for four channels). Significance: The system is useful for low-voltage low-power sensor nodes as a highly sensitive readout for the resistive sensor arrays. In addition, the developed system is useful for the stain sensors in the development of flexible hybrid electronics for wearable applications.