Shahid Malik

Shahid Malik

Auto-generated profile, based on publicly available information

Shahid Malik

Centre for Sensors, Instrumentation and Cyber Physical System Engineering, IIT Delhi, New Delhi, India

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2015 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
SMShahid Malik
Shahid Malik
KKKaushal Kishore
Kaushal Kishore
Tarikul  IslamTarikul Islam
Tarikul Islam
ZZZubair Hassan Zargar
Zubair Hassan Zargar
SAS.A. Akbar
S.A. Akbar

20 July 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
MZMohammad Zeeshan
Mohammad Zeeshan
MCMudra Chavda
Mudra Chavda
KEKhan Mohammad Ehshan
Khan Mohammad Ehshan
RNRajdip Nayek
Rajdip Nayek
SMShahid Malik
Shahid Malik
Positioning systems are widely used to determine the location of objects or individuals in a given environment. In underground mines, these systems are used to track the location of miners and equipment and ensure that they operate in safe and efficient areas. It allows mine operators to monitor the whereabouts of personnel and equipment and to respond quickly to emergencies. Additionally, accurate positioning information can optimize mining operations, improve equipment utilization, and reduce costs. Global positioning systems are not suitable for the underground environment. The ultra-high frequency (UHF) based systems are also unsuitable due to extreme attenuation. The non-radio-frequency (non-RF) techniques are preferred for underground mining due to their relatively small attenuation and interference caused by the surrounding rock and mineral formations in an underground mine that can occur with radio frequency (RF) signals. This allows for more accurate and reliable positioning within the mine. This research paper compares non-RF techniques, such as magnetic induction, visible light, and acoustic, for positioning within an underground mine. The study evaluates each technique’s accuracy, reliability, and feasibility and discusses their potential for use in underground mining environments. Overall, the study highlights the importance of considering multiple positioning options to optimize the safety and productivity of underground mining operations.

30 May 2019 in IEEE Sensors Letters
Verified
Journal Article
Closed access
SMShahid Malik
Shahid Malik
MAMeraj Ahmad
Meraj Ahmad
SLS. Laxmeesha
S. Laxmeesha
Tarikul  IslamTarikul Islam
Tarikul Islam
MBMaryam Shojaei Baghini
Maryam Shojaei Baghini

24 February 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
SMShahid Malik
Shahid Malik
LSLaxmeesha Somappa
Laxmeesha Somappa
MAMeraj Ahmad
Meraj Ahmad
MBMaryam Shojaei Baghini
Maryam Shojaei Baghini
This paper presents a fully analog auto-nulling bridge based capacitance-to-voltage (AN-C2V) converter circuit for measuring the capacitive component of the leaky capacitive sensors. The circuit utilizes an active bridge based architecture in which the quadrature components of the output are taken. An integrator-controller is used for auto-nulling. A unity gain, frequency-independent quadrature phase shift amplifier is designed for an accurate generation of 90° phase-shifted signal. Experiments conducted on the developed prototype demonstrate that the proposed AN-C2V system is able to estimate the sensor capacitor ranging from 47.2pF to 668.3pF with a maximum error of about ± 0.18% with respect to the commercial LCR meter. The effectiveness of the circuit is tested with the commercial leaky capacitive humidity sensor. The effect of leakage resistor, parasitic capacitor, frequency of excitation signal, and supply voltage is negligible on the final output, which results in a very robust and accurate solution for leaky capacitive sensors.

1 October 2018
Verified
Conference Paper
Closed access
SMShahid Malik
Shahid Malik
MAMeraj Ahmad
Meraj Ahmad
MPMeera Punjiya
Meera Punjiya
ASAydin Sadeqi
Aydin Sadeqi
MBMaryam Shojaei Baghini
Maryam Shojaei Baghini
SSSameer Sonkusale
Sameer Sonkusale
Respiration is a key vital sign indicative of an individual's health. Current approaches of respiration sensing require direct contact with the body. Moreover, they are expensive and need bulky holter monitors for continuous realtime monitoring. In this study, we propose a low-cost capacitive sensor fabricated using screen printing of carbon paste interdigitated electrodes on paper substrate for respiration monitoring. Cellulosic paper provides a microporous network to trap exhaled breath. Respiration causes the dielectric constant of the paper to change, mostly as a function of breath humidity, which in turn changes the capacitance of the sensor. The interdigitated electrodes configuration is shown to provide better response time compared to resistive configuration. A simple phase sensitive detector-based circuit was used to convert the capacitance change into a measurable output voltage. The MSP430 microcontroller was used for data acquisition and voltage measurement. A graphical user interface was designed for real time respiration monitoring. Experimental results validate the performance of this sensor.

28 August 2020 in IEEE Journal of Solid-State Circuits
Verified
Journal Article
Closed access
MAMeraj Ahmad
Meraj Ahmad
SMShahid Malik
Shahid Malik
SDSourya Dewan
Sourya Dewan
Arnesh BoseArnesh Bose
Arnesh Bose
Dinesh MaddipatlaDinesh Maddipatla
Dinesh Maddipatla
MBMaryam Shojaei Baghini
Maryam Shojaei Baghini
Most of the resistive sensors have a large baseline resistor and a relatively small incremental change in the resistor value due to the measurand. A half-bridge-based versatile Δ R/Rₛ measurement system for a wide range of resistive sensors is reported in this article. A four-phase auto-calibration-based differential and ratiometric operation is used to compensate for the baseline resistance of the sensor and the mismatches due to the non-ideal circuit parameters. A low-noise application-specific current generator and low noise, high CMRR current-mode instrumentation amplifier is designed and fabricated in UMC 180-nm technology. A prototype board of the Δ R/Rₛ measurement system is developed and tested. The experimental results show that the proposed system is able to detect even smaller ppm level of about 72 ppm of Δ R/Rₛ for the base resistor Rₛ value as high as 0.5 MΩ with a relative error of less than ±1%. The effect of the parasitic capacitors on the sensor response is also tested experimentally. Finally, the proposed system is tested with an in-house fabricated displacement sensor.