Julien Angot

Julien Angot

Auto-generated profile, based on publicly available information

Julien Angot

University of Grenoble Alpes

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 May 2016 in Physical Review Accelerators and Beams
Verified
Journal Article
Open access
PDF file
OTO. Tarvainen
O. Tarvainen
HKH. Koivisto
H. Koivisto
AGAlessio Galatà
Alessio Galatà
JAJ. Angot
J. Angot
TLT. Lamy
T. Lamy
LNlorenzo neri
lorenzo neri
This work describes the utilization of an injected Na231+ ion beam as a diagnostics of the helium plasma of a charge breeder electron cyclotron resonance ion source. The obtained data allows estimating the upper limit for the ion-ion collision mean-free path of the incident sodium ions, the lower limit of ion-ion collision frequencies for all charge states of the sodium ions and the lower limit of the helium plasma density. The ion-ion collision frequencies of high charge state ions are shown to be at least on the order of 1–10 MHz and the plasma density is estimated to be on the order of 1011  cm−3 or higher. The experimental results are compared to simulations of the Na231+ capture into the helium plasma. The results indicate that the lower breeding efficiency of light ions in comparison to heavier elements is probably due to different capture efficiencies in which the in-flight ionization of the incident 1+ ions plays a vital role.

1 March 2020 in Plasma Sources Science and Technology
Verified
Journal Article
Closed access
PDF file
JAJulien Angot
Julien Angot
MLMiha Luntinen
Miha Luntinen
TKTaneli Kalvas
Taneli Kalvas
HKHannu Koivisto
Hannu Koivisto
RKRisto Kronholm
Risto Kronholm
VTVille Toivanen
Ville Toivanen
A new method for determining plasma parameters from beam current transients resulting from short pulse 1+ injection of metal ions into a charge breeder electron cyclotron resonance ion source has been developed. The proposed method relies on few assumptions, and yields local values for the ionisation times 1 / n e σ v q → q + 1 inz , charge exchange times 1 / n 0 σ v q → q − 1 cx , the ion confinement times τ q , as well as estimates for the minimum plasma energy contents n e E e and the plasma triple products n e E e τ q . The method is based on fitting the current balance equation on the extracted beam currents of high charge state ions, and using the fitting coefficients to determine the postdictions for the plasma parameters via an optimisation routine. The method has been applied for the charge breeding of injected K + ions in helium plasma. It is shown that the confinement times of K q + charge states range from 2. 6 − 0.4 + 0.8 ms to 16. 4 − 6.8 + 18.3 ms increasing with the charge state. The ionisation and charge exchange times for the high charge state ions are 2. 6 − 0.5 + 0.5 ms–12. 6 − 3.2 + 2.6 ms and 3. 7 − 1.6 + 5.0 ms–357. 7 − 242.4 + 406.7 ms, respectively. The plasma energy content is found to be 2 . 5 − 1.8 + 4.3 × 1 0 15 eV cm −3 .

30 October 2018 in Physical Review Accelerators and Beams
Verified
Journal Article
Open access
PDF file
JAJulien Angot
Julien Angot
OTOlli Tarvainen
Olli Tarvainen
TTThomas Thuillier
Thomas Thuillier
MBMaud Baylac
Maud Baylac
TLThierry Lamy
Thierry Lamy
JJJosua Jacob
Josua Jacob
To qualify electron cyclotron resonance charge breeders, the method that is traditionally used to evaluate the charge breeding time consists in generating a rising edge of the injected beam current and measuring the time in which the extracted multicharged ion beam reaches 90% of its final current. It is demonstrated in the present paper that charge breeding times can be more accurately measured by injecting short pulses of 1+ions and recording the time resolved responses of N+ ions. This method is used to probe the effect of the 1+ion accumulation in the plasma known to disturb the buffer gas plasma equilibrium and is a step further in understanding the large discrepancies reported in charge breeding times. The experiments are conducted injecting a Rb+85 ion beam into the Laboratoire de Physique Subatomique et de Cosmologie (LPSC) charge breeder operated with helium as a buffer gas. The time needed for the extraction of 90% of the multicharged ions in short pulse mode is found slightly shorter (9%) than the charge breeding time measured with the traditional method. The charge breeding efficiency is identical with both methods. The pulse width and amplitude of the 1+ injection pulses have been varied to study their influence on the N+ response and temporal parameters are proposed to qualify the time response. The short pulse method can be used to study the influence of the ion source tuning parameters on the charge breeding temporal characteristics. For example, it is shown here that an increase of the minimum magnetic field strength of the LPSC charge breeder in the range 0.432–0.444 T improves the multicharged ion confinement in the electron cyclotron resonance plasma, and so increases the charge breeding efficiency. The short pulse method is also used to estimate the charge breeding efficiencies of radioactive Rb isotopes taking into account their half-lives and charge states. The neutron-rich heavy isotopes have short half-lives, which makes the charge state distributions shift to lower charge states and the estimated charge breeding efficiencies of high charge states being close to three times less in comparison to the stable ions.

4 November 2013 in Review of Scientific Instruments
Verified
Journal Article
Closed access
AGAlessio Galatà
Alessio Galatà
MCMichele Comunian
Michele Comunian
MMmario maggiore
mario maggiore
MMMattia Manzolaro
Mattia Manzolaro
JAJ. Angot
J. Angot
TLT. Lamy
T. Lamy
SPES (Selective Production of Exotic Species) is an INFN (Istituto Nazionale di Fisica Nucleare) project with the aim at producing and post-accelerating exotic beams to perform forefront research in nuclear physics. To allow post-acceleration of the radioactive ions, an ECR-based Charge Breeder (CB) developed on the basis of the Phoenix booster was chosen. The design of the complete beam line for the SPES-CB will be described: a system for stable 1+ beams production was included; special attention was paid to the medium resolution mass spectrometer after the CB to limit possible superposition of the exotic beams with the impurities present in the ECR plasma.

16 November 2022 in Physical Review E
Verified
Journal Article
Closed access
PDF file
MLM. Luntinen
M. Luntinen
VTV. Toivanen
V. Toivanen
HKH. Koivisto
H. Koivisto
JAJ. Angot
J. Angot
TTT. Thuillier
T. Thuillier
GCGiuseppe Castro
Giuseppe Castro
We establish multicomponent 1+ injection into a charge breeder electron cyclotron resonance ion source and an associated computational procedure as a noninvasive probe of the electron density ne, average electron energy 〈Ee〉, and the characteristic times of ionization, charge exchange, and ion confinement of stochastically heated, highly charged plasma. Multicomponent injection allows refining the ne, 〈Ee〉 ranges, reducing experimental uncertainty. Na/K injection is presented as a demonstration. The 〈Ee〉 and ne of a hydrogen discharge are found to be 600−300+600eV and 8−3+8×1011cm−3, respectively. The ionization, charge exchange, and confinement times of high charge state alkali ions are on the order of 1 ms–10 ms.

21 September 2018
Verified
Conference Paper
Closed access
PDF file
JAJulien Angot
Julien Angot
TTThomas Thuillier
Thomas Thuillier
OTOlli Tarvainen
Olli Tarvainen
MBMaud Baylac
Maud Baylac
JJJosua Jacob
Josua Jacob
PSPatrick Sole
Patrick Sole
LPSC has developed the PHOENIX electron cyclotron resonance Charge Breeder since 2000. The performances have been improved over time acting on the 1+ and N+ beam optics, the base vacuum and the 1+ beam injection. A new objective is to update the booster design to enhance high charge state production and 1+ N+ efficiencies, reduce the co-extracted background beam and improve the ion source tunability. The first step, consisting in increasing the peak magnetic field at injection from 1.2 T to 1.6 T was implemented and significant improvement in 1+N+ efficiencies are reported: 12.9% of 23Na8+, 24.2% of 40Ar8+, 13.3% of 132Xe26+ and 13% of 133Cs26+. The next steps of the upgrade are presented: modification of the axial magnetic structure, significant increase of the plasma chamber radius (72 to 90 mm), plasma heating at 18 GHz (instead of 14 GHz), reduction of chemical elements composing the plasma chamber wall and the surrounding beam line.