Department of Electronic Engineering, School of Electronic Science and Engineering (National Model Microelectronics College), and Fujian Key Laboratory of Ultrafast Laser Technology and Applications, Xiamen University, Xiamen, China
Auto-generated profile, based on publicly available information
Tongtong Xie
Department of Electronic Engineering, School of Electronic Science and Engineering (National Model Microelectronics College), and Fujian Key Laboratory of Ultrafast Laser Technology and Applications, Xiamen University, Xiamen, China
In this article, we have proposed and experimentally demonstrated an optical fiber refractive index (RI) sensing interrogation system realized by extrinsic Fabry-Perot interferometer (EFPI) structure based microwave photonic filter (MPF) technology. EFPI is considered as a sensing element, as well as a spectrum slicer of the MPF. The shift of the central frequency of the MPF’s passband caused by the change of the RI in the Fabry-Perot (FP) cavity can be monitored to demodulate the RI variation. In our experiment, four EFPI sensors with different FP cavity lengths have been applied for RI sensing test. The experimental results show that the sensitivity can be tailored by adjusting the length of the FP cavity, and the longer the length of the FP cavity, the higher the sensitivity can be achieved. When the length of the FP cavity is 960 μm, a high sensitivity of 1.2 GHz/RIU have been obtained. The proposed sensing system, can transfer the changes of the interference pattern in the optical domain to the central frequency shift of the MPF’s passband in electronic domain, and thus avoid the limitation of measurement range induced by the periodic characteristics of the FP interference spectrum. The proposed sensing system also have the advantages of high sensitivity, the feasibility of multiplexing, temperature insensitivity, good repeatability and stability, simple fabrication, and low cost, etc.
Temperature interference is often inevitable for fiber optic sensors in various practical applications. In this article, a reflective surface plasmon resonance (SPR) sensor based on a tapered multimode fiber (MMF) and seven-core fiber (SCF) structure is proposed for simultaneous measurement of RI and temperature. Along the SCF, polydimethylsiloxane (PDMS) film is applied to the Au-coated surface near the Ag-reflector to achieve the simultaneous measurement function and protect the silver film. To get a better sensing performance, the waist diameter is optimized by simulation and experiment. In the experiment, the maximum sensitivities of RI and temperature of the proposed sensor reach 2078 nm/RIU and -2.76 nm/°C, respectively. Furthermore, the reflective dual-parameter SPR sensor allows fewer samples and simplifies the measurement process, which has great potential in environmental monitoring, disease diagnosis, and biochemical sensing.
Traditional wearable fiber-optic sensors based on intensity demodulation are prone to interference and offer limited detection capabilities, whereas those utilizing wavelength demodulation provide better stability but at a higher cost. In this paper, we present a high precision strain sensing system based on an optoelectronic oscillator (OEO) for human pulse monitoring, which employs frequency demodulation to achieve exceptional accuracy while reducing system costs. The sensor head consists of a fiber optic Fabry-Pérot (FP) cavity, offering notable advantages such as the ease of fabrication, affordability, and high robustness. Experimental results indicate that our proposed strain sensing system achieves a high resolution of 0.021 με and the frequencies of detecting signals as low as 40 kHz, with excellent system stability demonstrated by a frequency drift of only 300 Hz over 15 minutes. The system’s performance was validated through pulse monitoring experiments, effectively addressing the challenges posed by the low-frequency and noise susceptibility of pulse signals. Some cardiovascular metrics, such as Pulse Wave Velocity (PWV) and Stiffness Index (SI), were successfully extracted, demonstrating the potential of this system for high-precision health monitoring, and offering a promising technological solution for future advancements in precise human pulse monitoring.
We propose and experimentally demonstrate a sensitivity enhanced fiber Bragg grating (FBG) curvature sensing system based on optoelectronic oscillator (OEO) with the enhanced Vernier effect. In this paper, two FBGs with opposite wavelength shift directions are constructed by using the silicon plate, and the time delay of the two loops of OEO changes in opposite, thus realizing OEO based sensitivity enhanced FBG curvature sensing system with the enhanced Vernier effect. The experimental results show that the sensitivity of single FBG curvature sensing system based on single-loop OEO is about 0.067 MHz/m -1 , while the sensitivity of two FBGs based curvature sensing system employing dual-loop OEO with the enhanced Vernier effect is 40.89 MHz/m -1 , which is 612 times that of a single loop OEO based FBG curvature sensing system. Moreover, the proposed FBG curvature sensing system shows great temperature insensitivity characteristics, in which temperature sensitivity of the proposed curvature sensing system is 5.57 kHz/°C, and the curvature error caused by the change of 1 °C is 1.358×10 -4 m -1 , which shows potential for realizing high sensitivity, fast, real-time demodulation in temperature-insensitive FBG curvature sensing system.