Mukesh Kumar Singh

Mukesh Kumar Singh

Auto-generated profile, based on publicly available information

Mukesh Kumar Singh

Department of Electrical Engineering, National Institute of Technology, Kurukshetra, India

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2016 in Comptes Rendus Palevol
Verified
Journal Article
Open access
Julien GarganiJulien Gargani
Julien Gargani
SASalah Abdessadok
Salah Abdessadok
ATAlina Tudryn
Alina Tudryn
CSCécile Chapon Sao
Cécile Chapon Sao
AMAnne Dambricourt Malassé
Anne Dambricourt Malassé
BKBaldev Karir
Baldev Karir
The Masol paleonto-archeological site is located in the Siwalik Frontal Range in the north of Chandigarh (Punjab, NW India). Many fossils and stone tools can be observed in the colluviums that overlap the present topography constituted by Late Pliocene continental sediments. The Masol paleonto-archeological site is located in the center of a trenched anticline compatible with the direction of plate convergence between India and Eurasia. Erosion processes are very actives and efficient in the area. Around 80m of vertical erosion occurred in the Patiali Rao valley and regressive erosion incised the Siwalik Hills for ∼12km. At least two levels of fluvial terraces are visible in the Patiali Rao valley and laterally apart the Pichhli River. River bank erosion, gullies, collapses, cavities, regressive erosion, landslides and in situ disaggregation have been observed and are responsible of the significant excavation of the anticline. Substrate composed of sand, sandstone and silt is very erodible in case of heavy rain. Slope destabilizations by seasonal monsoon are responsible of a large part of the colluviums overlapping the present slopes. Some colluviums could be due also to in situ disaggregation of sandstone formations. Due to the very active erosion and to their position on the topography, we believe that these colluviums are very recent

1 February 2016 in Comptes Rendus Palevol
Verified
Journal Article
Open access
ATAlina Tudryn
Alina Tudryn
SASalah Abdessadok
Salah Abdessadok
Julien GarganiJulien Gargani
Julien Gargani
AMAnne Dambricourt Malassé
Anne Dambricourt Malassé
CGClaire Gaillard
Claire Gaillard
SMSerge Miska
Serge Miska
The Quranwala zone (Siwalik Range, NW India) is known for its Late Pliocene vertebrates. Since 2008, cut marks and stone tools have been collected from Masol. The sedimentary series belongs to the Subathu sub-basin. These sub-Himalayan deposits contain repetitive sequences (∼170m thick) of silt/clays and sandstones corresponding to the cyclical influx of detrital material in a fluvial environment. Particular features of lithological units allow identification of the stratigraphic position of different paleonto-archeological localities. A first pale environmental reconstruction was enabled by analysis of clay and magnetic minerals. Iron minerals such as haematite and goethite indicate dominant oxic conditions during and after deposition. Clay minerals are of detrital origin, and were supplied from Himalaya by rivers. Illite, the result of physical weathering, is dominant. Smectite present in the lower part of the sequence, was probably supplied from Lesser Himalaya (Suresh et al., 2004). Its presence suggests that the studied area was still a paleo-drainage area for major river(s) during the time considered here

1 February 2016 in Comptes Rendus Palevol
Verified
Journal Article
Open access
SASalah Abdessadok
Salah Abdessadok
CSCécile Chapon Sao
Cécile Chapon Sao
ATAlina Tudryn
Alina Tudryn
AMAnne Dambricourt Malassé
Anne Dambricourt Malassé
MSMukesh Singh
Mukesh Singh
SPSurinder Pal
Surinder Pal
Since 2008, the Indo-French research program ‘Siwaliks’ has been prospecting in the Late Pliocene formations of the Chandigarh anticline in the Northwest of India (Siwalik Frontal Range, Himalayan foothills). More than 200 quartzite tools and 1500 terrestrial vertebrate fossils have been collected from a Pliocene continental formation near the village of Masol. Several fossils show exceptional cut marks. A complete geological investigation of this area was performed in order to reconstruct the paleoenvironment. The geological sequences of the three major paleonto-archeological localities, Masol 1, Masol 6 and Masol 13, were studied. Silt and sandstone samples of the Quranwala fossiliferous area were collected to correlate the stratigraphy among the three localities and to understand the origins of the sediments. Three different techniques were used to analyze the sediments: a granulometric approach, X-ray diffraction and an analysis of heavy minerals. The sediment analysis demonstrates the relationship between the sample collected in Masol and the dismantling of the Higher as well as of the Lesser Himalaya. During the Late Pliocene, Masol was a floodplain with rich continental and freshwater fauna. The rivers were relatively calm, as indicated by the presence of apatite. Despite this, the quasi-simultaneous accumulations of quartzite cobbles and clay, as well as the presence of carcasses of small and large herbivores, suggest sudden climate variations probably due to the monsoon

13 January 2026 in Engineering Research Express
Verified
Journal Article
Closed access
AGAtma Ram Gupta
Atma Ram Gupta
MSMukesh Kumar Singh
Mukesh Kumar Singh
AKAshwani Kumar
Ashwani Kumar
The electrical distribution network needs to be reconfigured more carefully due to steadily rising power demand and increased greenhouse gas emissions, necessitating the deployment of renewable-based distributed energy resources. Reconfiguring raises several concerns, including increased line losses, voltage variation, and other power quality issues. To address these problems, D-FACTS devices play a critical role in the era of modern electronic devices. This work tackles the issues discussed above and expands on the main studies. (i) The analysis of mesh distribution network with reconfiguration; (ii) Allocation of DGs, such as solar and wind, optimally to benefit the environment; (iii) Deployment of UPQC within the renewable-integrated mesh distribution network; and (iv) techno-economic analysis for various load models will be conducted for each objective. The authors analysed the IEEE-33 and 69-bus mesh distribution networks to evaluate the feasibility of these goals. According to the findings, the combination of DG1+DG2, UPQC, and network reconfiguration considerably improves the overall voltage profile by 85% and 76.33%, real power losses by 79.5% and 92.8%, and reactive power losses by 68% and 88% compared with the basic scenario of IEEE-33 and 69-bus mesh distribution networks, respectively.


20 April 2026 in Engineering Research Express
Verified
Journal Article
Closed access
MSMukesh Kumar Singh
Mukesh Kumar Singh
JBJitendra Singh Bhadoriya
Jitendra Singh Bhadoriya
AGAtma Ram Gupta
Atma Ram Gupta
RRRohit Ray
Rohit Ray
AKAshwani Kumar
Ashwani Kumar
The electrical distribution system, with its radial structure and passive nature, is prone to high power losses due to imbalanced load demand and inadequate reactive power, resulting in a poor voltage profile. This paper presents a novel metaphor-less RAO algorithm for the optimal sizing and location of Distributed Generation to achieve optimal penetration levels. This study introduces new location and size deviation indices to assess the impact of DG installation. The proposed methodology employs a multi-objective function that minimizes active and reactive power losses and maximizes the minimum voltage, using a weighted-sum approach. The method is applied to the IEEE-33 bus radial distribution system with various load models, including residential, commercial, industrial, and electric-vehicle battery-charging loads, as well as combinations of these models. The simulation results across various scenarios demonstrate the efficiency of the proposed algorithm at different DG penetration levels and for different load types and demand profiles. On the IEEE-33 bus, power losses were reduced to 48.70%, 64.56%, and 69.07% after DG allocation with unity, fixed, and optimal power factors, respectively, under the constant-load model. Additionally, the presented work determines the optimal range of power factor-based DG penetration for distinct load models and the role of DG allocation in the electrical distribution system during the critical emergency conditions of the COVID-19 pandemic.