Michael Vogt

Michael Vogt

Auto-generated profile, based on publicly available information

Michael Vogt

Institute of Electronic Circuits, Ruhr University Bochum, 44801 Bochum, Germany

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 March 2015 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
MGMartin Gevers
Martin Gevers
PGPatrik Gebhardt
Patrik Gebhardt
SWStephan Westerdick
Stephan Westerdick
MVMichael Vogt
Michael Vogt
TMThomas Musch
Thomas Musch
Electrical impedance tomography (EIT) is used to determine the spatial conductivity distribution of a measurement environment that involves several applications in the areas of process engineering and medical diagnostics. In common EIT systems, the measurements are performed by means of current patterns which are injected into the measurement environment using a serial time-division-multiplexing (TDM) scheme for the excitation of different electrodes. The measurement rate can be increased by performing parallel excitation using orthogonal signals. In this paper, a code-division-multiplexing (CDM) measurement procedure is presented. To optimize the separation between different measurement channels and the dynamic range, orthogonal Walsh-Hadamard codes are used. The measurements are conducted with a fast EIT system with nine parallel excitation sources and 18 parallel measurement channels. The measured crosstalk rejection between different channels is larger than 98 dB. The maximum absolute deviation between different measurement sets for repeated measurements is less than 24 μV with a mean standard deviation of less than 8.2 μV. The dynamic range for impedance measurements based on different excitation procedures (TDM, frequency-division-multiplexing, and CDM) has been determined. Furthermore, reconstructed conductivity distributions based on measurements with the different excitation procedures have been compared with each other for different measurement scenarios (a root mean square difference of less than 1.2%). Finally, the influences of frequency-dependent measurement objects on the excitation procedures have been discussed.

21 June 1999
Verified
Conference Paper
Closed access
PDF file
HEHelmut Ermert
Helmut Ermert
MVMichael C. Vogt
Michael C. Vogt
Utilizing transducers with center frequencies and bandwidths both up to 100 MHz high frequency ultrasound allows high resolution imaging in fluids and tissue with a resolution down to approximately 10 micrometers . In addition to the increased resolution for medical imaging the backscatter properties of biological tissue are of considerable diagnostic advantage which change more rapidly with increasing frequency than the spatial resolution does. Because of the increasing attenuation of ultrasound in tissue at higher frequencies only small near surface areas can be imaged. For applications in dermatology recent research activities and instrument developments have included B-Scan systems (skin: thickness of layers, tumors, inflammatory diseases), flow visualization concepts (diagnosis of the cutaneous microcirculation), and tissue characterization (tumorous skin areas). As transducer and array technology has limitations high frequency imaging systems mainly utilize mechanically scanned single element transducers. They require special scanning procedures as well as signal processing techniques in order to optimize resolution, range, and signal-to-noise ratio. The paper will give an overview of these techniques and will also present some examples of applications in dermatology.

2 April 2020 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
GNGordon Notzon
Gordon Notzon
RSRobert Storch
Robert Storch
TMThomas Musch
Thomas Musch
MVMichael Vogt
Michael Vogt
The measurement of the electromagnetic reflection characteristics of a device under test (DUT) is of interest in a large variety of applications. For this task, the established lowcost approach of using pulse-shaped excitation signals is more and more replaced by employing continuous binary coded excitation signals. The reason behind this is that reflection measurement systems with continuous signals offer a larger signal-to-noise ratio (SNR), which allows for a larger dynamic range compared to pulsed systems for the same measurement time. However, a correlator is needed to access the impulse response function (IRF) of the DUT. In this contribution, a reflection measurement system is presented using a hybrid correlation approach. In the latter, the correlation is performed using a combination of a hardware and a software correlator. The hardware of the developed measurement system has been optimized to achieve a high dynamic range and a high measurement accuracy. A demonstrator system has been realized using so-called almost perfect auto-correlation sequences (APAS) with a chip clock of 5 Gchip=s. With the optimized hardware, a dynamic range of 82 dB has been achieved. The measurement accuracy has been validated by means of distance measurements versus a high accuracy laser reference system achieving a maximum error of 25 μm. Furthermore, the measured reflection coefficient of a low-pass filter has been compared with the results obtained with a vector network analyzer (VNA).

3 May 2018
Verified
Book Chapter
Closed access
PDF file
MVMichael Vogt
Michael Vogt

1 October 2011
Verified
Conference Paper
Closed access
MVM. Vogt
M. Vogt
HEH. Ermert
H. Ermert
The analysis of homogeneous liquids and immiscible mixtures of different liquids (emulsions) is of interest in many industrial processes. Ultrasound based methods allow to measure various acoustic parameters (speed of sound, acoustic impedance, frequency-dependent attenuation), which are suitable to quantitatively characterize liquids and emulsions. In this work, a high-frequency ultrasound (HFUS) measurement cell working in the range from 15 to 35 MHz is presented. The design of the cell and approaches for quantitative ultrasound analysis are discussed based on an analytical one-dimensional model for the propagation of ultrasound waves. Appropriate echo signal processing strategies for parameter extraction and calibration techniques have been developed. Results of the evaluation of the implemented system are presented.

24 June 2022 in arXiv
Verified
Preprint
Open access
PDF file
MVMichael Vogt
Michael Vogt
CWChristopher Walsh
Christopher Walsh
OLOliver Linton
Oliver Linton
Interactive fixed effects are a popular means to model unobserved heterogeneity in panel data. Models with interactive fixed effects are well studied in the low-dimensional case where the number of parameters to be estimated is small. However, they are largely unexplored in the high-dimensional case where the number of parameters is large, potentially much larger than the sample size itself. In this paper, we develop new econometric methods for the estimation of high-dimensional panel data models with interactive fixed effects. Our estimator is based on similar ideas as the very popular common correlated effects (CCE) estimator which is frequently used in the low-dimensional case. We thus call our estimator a high-dimensional CCE estimator. We derive theory for the estimator both in the large-T-case, where the time series length T tends to infinity, and in the small-T-case, where T is a fixed natural number. The theoretical analysis of the paper is complemented by a simulation study which evaluates the finite sample performance of the estimator.