Thomas Musch

Thomas Musch

Auto-generated profile, based on publicly available information

Thomas Musch

Institute of Electronic Circuits, Ruhr University Bochum, Bochum, Germany

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 May 2018 in Energies
Verified
Journal Article
Open access
PDF file
MMMalte Mallach
Malte Mallach
MGMartin Gevers
Martin Gevers
PGPatrik Gebhardt
Patrik Gebhardt
TMThomas Musch
Thomas Musch
In the process industry, measurement systems are required for process development and optimization, as well as for monitoring and control. The processes often involve multiphase mixtures or flows that can be analyzed using tomography systems, which visualize the spatial material distribution within a certain measurement domain, e.g., a process pipe. In recent years, we studied the applicability of soft-field electromagnetic tomography methods for multiphase flow imaging, focusing on concepts for high-speed data acquisition and image reconstruction. Different non-intrusive electrical impedance and microwave tomography systems were developed at our institute, which are sensitive to the local contrasts of the electrical properties of the materials. These systems offer a very high measurement and image reconstruction rate of up to 1000 frames per second in conjunction with a dynamic range of up to 120 dB. This paper provides an overview of the underlying concepts and recent improvements in terms of sensor design, data acquisition and signal processing. We introduce a generalized description for modeling the electromagnetic behavior of the different sensors based on the finite element method (FEM) and for the reconstruction of the electrical property distribution using the Gauss–Newton method and Newton’s one-step error reconstructor (NOSER) algorithm. Finally, we exemplify the applicability of the systems for different measurement scenarios. They are suitable for the analysis of rapidly-changing inhomogeneous scenarios, where a relatively low spatial resolution is sufficient.

12 July 2021 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Open access
BHBirk Hattenhorst
Birk Hattenhorst
LPLukas Piotrowsky
Lukas Piotrowsky
NPNils Pohl
Nils Pohl
TMThomas Musch
Thomas Musch
We propose a millimeter-wave (mmWave) sensor to monitor gases and aerosols based on time-of-flight (ToF), thus, on the real refractive index. It utilizes an ultrawideband frequency-modulated continuous-wave (FMCW) radar operating from 72 to 92 GHz at a sampling rate of 500 Hz. Also, we introduce a model for simulation of the refractive index of arbitrary gases at mmWave frequencies using molecular spectroscopic data. Simulations then allow the identification of the respective gas under test. We characterized the performance of the sensor regarding the refractive index within various experiments. The precision is 0.027 ppm, and the 20-h long-term stability is better than 0.2 ppm. The linearity is at least 1.5 ppm. Due to sophisticated temperature compensation, the temperature drift is less than 10 ppm for 30 K. Since the sensor is accurate, precise, and robust, it is perfect for in-process real-time monitoring and classification of gases or aerosols in the industry.

19 March 2015 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
MGMartin Gevers
Martin Gevers
PGPatrik Gebhardt
Patrik Gebhardt
SWStephan Westerdick
Stephan Westerdick
MVMichael Vogt
Michael Vogt
TMThomas Musch
Thomas Musch
Electrical impedance tomography (EIT) is used to determine the spatial conductivity distribution of a measurement environment that involves several applications in the areas of process engineering and medical diagnostics. In common EIT systems, the measurements are performed by means of current patterns which are injected into the measurement environment using a serial time-division-multiplexing (TDM) scheme for the excitation of different electrodes. The measurement rate can be increased by performing parallel excitation using orthogonal signals. In this paper, a code-division-multiplexing (CDM) measurement procedure is presented. To optimize the separation between different measurement channels and the dynamic range, orthogonal Walsh-Hadamard codes are used. The measurements are conducted with a fast EIT system with nine parallel excitation sources and 18 parallel measurement channels. The measured crosstalk rejection between different channels is larger than 98 dB. The maximum absolute deviation between different measurement sets for repeated measurements is less than 24 μV with a mean standard deviation of less than 8.2 μV. The dynamic range for impedance measurements based on different excitation procedures (TDM, frequency-division-multiplexing, and CDM) has been determined. Furthermore, reconstructed conductivity distributions based on measurements with the different excitation procedures have been compared with each other for different measurement scenarios (a root mean square difference of less than 1.2%). Finally, the influences of frequency-dependent measurement objects on the excitation procedures have been discussed.

17 July 2023 in IEEE Transactions on Radar Systems
Verified
Journal Article
Open access
BWBent Walther
Bent Walther
AFAndré Froehly
André Froehly
RHReinhold Herschel
Reinhold Herschel
MDMarcel van Delden
Marcel van Delden
PWPatrick Wallrath
Patrick Wallrath
TMThomas Musch
Thomas Musch
During the production of fiber composites, individual layers can be displaced, which can drastically influence the load-bearing capacity of the object to be manufactured. Existing systems in the field of non-destructive testing of fiber composites are either impractical to use in everyday production or do not offer the possibility of examining the structure of the individual fiber layers. For this reason, we present a novel sensor concept that can detect typical defects caused during manufacturing. The concept is based on a millimeter wave SAR approach using a fully polarimetric FMCW radar sensor working at a center frequency of 60.5 GHz, with 17GHz bandwidth. The sensor offers a phase noise of -77 dBc/Hz at 1MHz offset from the carrier, with chirp times of 1 ms over the whole bandwidth, while maintaining a RMS frequency deviation of 1.24 ppm. Using a polarimetric decomposition scheme, we can detect the displacement of individual fiber layers, although the thickness of the layers is below the theoretically achievable range resolution of the radar.

27 January 2023 in International Journal of Microwave and Wireless Technologies
Verified
Journal Article
Open access
PDF file
TBTobias T. Braun
Tobias T. Braun
MDMarcel van Delden
Marcel van Delden
CBChristian Bredendiek
Christian Bredendiek
JSJan Schoepfel
Jan Schoepfel
SHStephan Hauptmeier
Stephan Hauptmeier
NPNils Pohl
Nils Pohl
Radio telescopes are among the applications with the highest demands on a local oscillator (LO), which is used to receive and process the signals coming from the sky. Therefore the modules providing the required LO signal have traditionally been big and complicated. To overcome this disadvantage, we implement our own integrated frequency synthesizer inside a small LO module in this article. With this synthesizer we are able to achieve a jitter of only 50 fs integrated from 10 Hz to 2.5 GHz offset at a carrier frequency of 75 GHz. This is in part achieved by a very low in-band phase noise of −111.8 dBc at 10 kHz offset. The stabilizable frequency range is 62–88 GHz. Thus achieving promising results to fulfill this very demanding task with integrated frequency synthesizers in the future.

10 August 2022 in Sensors
Verified
Journal Article
Open access
PDF file
KOKerstin Orend
Kerstin Orend
CBChristoph Baer
Christoph Baer
TMThomas Musch
Thomas Musch
In this contribution, we present a measurement system for material characterization in the millimeter-wave range that requires extremely small amounts of sample material. With the help of a dielectric waveguide, it is possible to measure the complete S-parameters with only one port. Fundamentals regarding dielectric waveguides and algorithms are explained, which form the basis of the measurement system. Within the scope of this work, an existing waveguide system was extended and optimized. In addition, two algorithms were implemented to determine permittivity. Finally, measurements were carried out to prove the function of the measurement setup and compared to existing measurement setups.