Gordon Notzon

Gordon Notzon

Auto-generated profile, based on publicly available information

Gordon Notzon

Institute of Electronic Circuits, Ruhr University Bochum, 44801 Bochum, Germany

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2013
Verified
Conference Paper
Closed access
CBChristoph Baer
Christoph Baer
GNGordon Notzon
Gordon Notzon
CDChristoph Dahl
Christoph Dahl
CSChristian Schulz
Christian Schulz
BWBianca Will
Bianca Will
TMThomas Musch
Thomas Musch
In this contribution, a novel measuring method for the differentiation of intra vascular plaque types is presented. The proposed method operates contact free because of the mm-wave based approach. Fundamentals concerning material properties of blood and plaque, and electromagnetic barrier reflections are discussed. Furthermore, a test setup consisting of a miniaturized sensor setup is introduced that clarifies the measuring concept. Additionally, results of 3D electromagnetic field simulations as well as first measurements ex situ performed on non-human genetic materials are shown and discussed in detail.

1 October 2017
Verified
Conference Paper
Closed access
GNGordon Notzon
Gordon Notzon
LPLukas Polzin
Lukas Polzin
RSRobert Storch
Robert Storch
TMThomas Musch
Thomas Musch
MVMichael Vogt
Michael Vogt

1 September 2018
Verified
Conference Paper
Closed access
GNGordon Notzon
Gordon Notzon
RSRobert Storch
Robert Storch
TMThomas Musch
Thomas Musch
MVMichael Vogt
Michael Vogt
Pseudo-random binary coded excitation signals are being increasingly used for electromagnetic network analysis. Various types of sequences with different correlation properties are available. Unfortunately, nonidealities of real measurement systems, like noise and nonlinearities, degrade the correlation functions. In this contribution a simulator is presented that takes several nonidealities into account. The impact of these nonidealities on two commonly used sequence types, the maximum length sequence (MLS) and the almost perfect autocorrelation sequence (APAS), on the achievable dynamic range (DR) are investigated. In the framework of the presented study, it was taken care that its results can be transferred into hardware requirements.

1 November 2017
Verified
Conference Paper
Closed access
GNGordon Notzon
Gordon Notzon
LPLukas Polzin
Lukas Polzin
DFDennis Falkenberg
Dennis Falkenberg
RSRobert Storch
Robert Storch
TMThomas Musch
Thomas Musch
MVMichael Vogt
Michael Vogt
For the realization of an m-sequence-based reflec-tometer, a correlator performing a pulse compression is necessary in order to determine the impulse response function (IRF) of a device under test (DUT). Using a hardware correlator, a time delayed version of the m-sequence transmit signal is required. In this contribution, a concept for the generation of two m-sequences with a fast and precisely adjustable time lag between them is presented. Programmable linear feedback shift registers (LFSRs) are used for generating the m-sequences. The desired time lag is realized by using different initial states of the LFSRs. To guarantee that the time lag is set within one clock period, a select pulse generator (SPG) has been designed and implemented into the system. The concept has been validated by means of measurements using a realized demonstrator setup. According results show the fast time lag adjustment. Furthermore, reflection measurements have been performed with different coupler architectures and a coaxial cable with a length of 20m. Results obtained with two different couplers are compared regarding the achievable dynamic range.

1 September 2018
Verified
Conference Paper
Closed access
GNGordon Notzon
Gordon Notzon
RSRobert Storch
Robert Storch
TMThomas Musch
Thomas Musch
MVMichael Vogt
Michael Vogt

2 April 2020 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
GNGordon Notzon
Gordon Notzon
RSRobert Storch
Robert Storch
TMThomas Musch
Thomas Musch
MVMichael Vogt
Michael Vogt
The measurement of the electromagnetic reflection characteristics of a device under test (DUT) is of interest in a large variety of applications. For this task, the established lowcost approach of using pulse-shaped excitation signals is more and more replaced by employing continuous binary coded excitation signals. The reason behind this is that reflection measurement systems with continuous signals offer a larger signal-to-noise ratio (SNR), which allows for a larger dynamic range compared to pulsed systems for the same measurement time. However, a correlator is needed to access the impulse response function (IRF) of the DUT. In this contribution, a reflection measurement system is presented using a hybrid correlation approach. In the latter, the correlation is performed using a combination of a hardware and a software correlator. The hardware of the developed measurement system has been optimized to achieve a high dynamic range and a high measurement accuracy. A demonstrator system has been realized using so-called almost perfect auto-correlation sequences (APAS) with a chip clock of 5 Gchip=s. With the optimized hardware, a dynamic range of 82 dB has been achieved. The measurement accuracy has been validated by means of distance measurements versus a high accuracy laser reference system achieving a maximum error of 25 μm. Furthermore, the measured reflection coefficient of a low-pass filter has been compared with the results obtained with a vector network analyzer (VNA).