Toshikazu Imae

Toshikazu Imae

Auto-generated profile, based on publicly available information

Toshikazu Imae

Department of Radiology, The University of Tokyo Hospital, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655, Japan

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 November 2014 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
HYHideomi Yamashita
Hideomi Yamashita
AHAkihiro Haga
Akihiro Haga
WTWataru Takahashi
Wataru Takahashi
RTRyousuke Takenaka
Ryousuke Takenaka
TIToshikazu Imae
Toshikazu Imae
KNKeiichi Nakagawa
Keiichi Nakagawa
The aim of this study was to report the outcome of primary or metastatic lung cancer patients undergoing volumetric modulated arc therapy for stereotactic body radiation therapy (VMAT-SBRT). From October 2010 to December 2013, consecutive 67 lung cancer patients received single-arc VMAT-SBRT using an Elekta-synergy system. All patients were treated with an abdominal compressor. The gross tumor volumes were contoured on 10 respiratory phases computed tomography (CT) datasets from 4-dimensional (4D) CT and merged into internal target volumes (ITVs). The planning target volume (PTV) margin was isotropically taken as 5 mm. Treatment was performed with a D95 prescription of 50 Gy (43 cases) or 55 Gy (12 cases) in 4 fractions for peripheral tumor or 56 Gy in 7 fractions (12 cases) for central tumor. Among the 67 patients, the median age was 73 years (range, 59-95 years). Of the patients, male was 72% and female 28%. The median Karnofsky performance status was 90-100% in 39 cases (58%) and 80-90% in 20 cases (30%). The median follow-up was 267 days (range, 40-1162 days). Tissue diagnosis was performed in 41 patients (61%). There were T1 primary lung tumor in 42 patients (T1a in 28 patients, T1b in 14 patients), T2 in 6 patients, three T3 in 3 patients, and metastatic lung tumor in 16 patients. The median mean lung dose was 6.87 Gy (range, 2.5-15 Gy). Six patients (9%) developed radiation pneumonitis required by steroid administration. Actuarial local control rate were 100% and 100% at 1 yearar, 92% and 75% at 2 years, and 92% and 75% at 3 years in primary and metastatic lung cancer, respectively (p =0.59). Overall survival rate was 83% and 84% at yearyear, 76% and 53% at 2 years, and 46% and 20% at 3 years in primary and metastatic lung cancer, respectively (p =0.12). Use of VMAT-based delivery of SBRT in primary in metastatic lung tumors demonstrates high local control rates and low risk of normal tissue complications.

1 July 2017 in Physica Medica
Verified
Journal Article
Closed access
DSDousatsu Sakata
Dousatsu Sakata
AHAkihiro Haga
Akihiro Haga
SKSatoshi Kida
Satoshi Kida
TIToshikazu Imae
Toshikazu Imae
STShigeharu Takenaka
Shigeharu Takenaka
KNKeiichi Nakagawa
Keiichi Nakagawa

12 July 2020 in Radiological Physics and Technology
Verified
Journal Article
Closed access
PDF file
TIToshikazu Imae
Toshikazu Imae
AHAkihiro Haga
Akihiro Haga
YWYuichi Watanabe
Yuichi Watanabe
STShigeharu Takenaka
Shigeharu Takenaka
TSTakashi Shiraki
Takashi Shiraki
OAOsamu Abe
Osamu Abe

11 December 2023 in Physica Medica
Verified
Journal Article
Closed access
TNTakahiro Nakamoto
Takahiro Nakamoto
HYHideomi Yamashita
Hideomi Yamashita
HJHaruka Jinnouchi
Haruka Jinnouchi
KNKanabu Nawa
Kanabu Nawa
TIToshikazu Imae
Toshikazu Imae
KNKeiichi Nakagawa
Keiichi Nakagawa

1 January 2009 in Magnetic Resonance in Medical Sciences
Verified
Journal Article
Closed access
PDF file
TIToshikazu Imae
Toshikazu Imae
HSHiroyuki Shinohara
Hiroyuki Shinohara
MSMasaki Sekino
Masaki Sekino
SUShoogo Ueno
Shoogo Ueno
Hiroyuki OhsakiHiroyuki Ohsaki
Hiroyuki Ohsaki
KOKuni Ohtomo
Kuni Ohtomo
The signal intensity of diffusion-weighted imaging (DWI) is sensitive to the intra- and extracellular diffusion coefficient of water and cell membrane permeability. We applied a method we proposed in previous papers to estimate noninvasively the membrane permeability and intracellular diffusion coefficient of normal human brain (gray matter) in 3 normal volunteers. We theoretically compared predicted signals and experiment results using a 1.5-tesla magnetic resonance (MR) imaging system. We acquired images using an echo planar imaging (EPI) sequence, applying motion-probing gradient (MPG) pulses in 3 directions. We periodically performed numerical simulations for various combinations of membrane permeability and intracellular diffusion coefficients using the finite-difference method. By minimizing the difference between signals obtained experimentally and those from numerical simulation, we could estimate membrane permeability (76±9 mm2/s μm) and intracellular diffusion coefficient (1.0±0.0 mm2/s) for the human brain. The estimated membrane permeability was the criterion value for diagnosing disease in gray matter.

12 November 2020 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
TIToshikazu Imae
Toshikazu Imae
STShigeharu Takenaka
Shigeharu Takenaka
YWYuichi Watanabe
Yuichi Watanabe
AAAtsushi Aoki
Atsushi Aoki
KMKanako Matsuda
Kanako Matsuda
OAOsamu Abe
Osamu Abe
Using a plane‐parallel advanced Markus ionization chamber and a stack of water‐equivalent solid phantom blocks, percentage surface and build‐up doses of Elekta 6 MV flattening filter (FF) and flattening‐filter‐free (FFF) beams were measured as a function of the phantom depth for field sizes ranging from 2 × 2 to 10 × 10 cm2. It was found that the dose difference between the FF and the FFF beams was relatively small. The maximum dose difference between the FF and the FFF beams was 4.4% at a depth of 1 mm for a field size of 2 × 2 cm2. The dose difference was gradually decreased while the field size was increased up to 10 × 10 cm2. The measured data were also compared to published Varian FF and FFF data, suggesting that the percentage surface and build‐up doses as well as the percentage dose difference between FF and FFF beams by our Elekta linac were smaller than those by the Varian linac.