Thomas Franz Bechteler

Thomas Franz Bechteler

Auto-generated profile, based on publicly available information

Thomas Franz Bechteler

Max Planck Institute for Extraterrestrial Physics, Garching, Germany

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 January 2024 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
AAAlexander Altmann
Alexander Altmann
TBThomas F. Bechteler
Thomas F. Bechteler
PLPeter Lechner
Peter Lechner
CFCarlo Fiorini
Carlo Fiorini
KNKirpal Nandra
Kirpal Nandra
A silicon drift detector module has been developed to be used in high time resolution X-ray spectroscopy. The module consists of a 19-cell silicon drift detector chip and three readout application-specific integrated circuits (ASIC). With respect to timing and energy resolution, the readout ASIC with its programmable setting parameters is characterized. Based on the results of this characterization, analytical rules for these setting parameters are established to obtain the optimum performance of the module. The performance of the module is verified by means of measurements. With the ascertained parameter values and selecting the available shaping time of 1.02 μs, a minimum time interval of 1.87 μs between pulses and an energy resolution of 176 eV at 5.9 keV and at a temperature of -30°C are achieved.

6 September 2011 in IEEE Microwave Magazine
Verified
Journal Article
Open access
TBThomas Franz Bechteler
Thomas Franz Bechteler
ABAyse Sevinc Aydinlik Bechteler
Ayse Sevinc Aydinlik Bechteler
The groove guide is a low-loss waveguide that was proposed by Tischer in 1963 as an alternative to classic waveguides. Its basic structure, can be divided into an inner and two outer region. The inner region exhibits a lower phase velocity. Hence, the electromagnetic field is concentrated in the inner region and propagates along the groove. In the outer regions, the electromagnetic field is eavnescent.

12 June 2025 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
TBThomas F. Bechteler
Thomas F. Bechteler
AAAlexander Altmann
Alexander Altmann
JRJonas P. Reiffers
Jonas P. Reiffers
PLPeter Lechner
Peter Lechner
CFCarlo Fiorini
Carlo Fiorini
For X-ray imaging and photon detection, silicon drift detectors (SDD) with several cells on a single chip and associated application-specific integrated circuits (ASIC) with multi-channel readout are widely used. This work presents a reset management circuit for a parallelized readout system for multi-cell SDDs. The readout system under investigation consists of a 19-cell SDD chip and three ASICs with reset capabilities. Yet another reset management circuit is required which handles the seamless reset operation between all ASICs and the SDD chip. With regard to its versatility and real-time capability, a field programmable gate array (FPGA) is used to implement the reset management circuit. For the design and implementation of this circuit the time delays of all involved signal paths are investigated in detail. Measurements prove the functionality of the presented reset management. Furthermore, it is also shown how the reset management influences the dead time of the entire system. Although this work covers a system with three ASICs, the reset management is applicable for other SDD systems using two or more parallelized readout circuits.

27 March 2008 in Microwave and Optical Technology Letters
Verified
Journal Article
Open access
PDF file
TBThomas F. Bechteler
Thomas F. Bechteler
AKAlp Kustepeli
Alp Kustepeli
SBSevinc A. Bechteler
Sevinc A. Bechteler
Three different coupling structures for a groove guide resonator operating at 10 GHz are investigated. First, propagatable modes are determined analytically. Then, the efficiency of the coupling structures is investigated by means of the method of moments and measurements. Finally, a groove guide resonator is designed and the resonance spectrum for each coupling structure is computed numerically, applying the finite-difference time-domain method. Numerical results are compared with experimental measurements. There is good agreement between the measured and simulated data. © 2008 Wiley Periodicals, Inc. Microwave Opt Technol Lett 50: 1406–1410, 2008; Published online in Wiley InterScience (www.interscience.wiley.com). DOI 10.1002/mop.23372