Peter Lechner

Dr. Peter Lechner

orcid

Research Focus & Metrics

Academic Career Length

34Years (1993-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 April 2021 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Open access
MPMatteo Porro
Matteo Porro
LALadislav Andricek
Ladislav Andricek
SAStefan Aschauer
Stefan Aschauer
ACAndrea Castoldi
Andrea Castoldi
MDMattia Donato
Mattia Donato
CWCornelia B. Wunderer
Cornelia B. Wunderer
The first DSSC 1-Mpixel camera became available at the European XFEL (EuXFEL) in the Hamburg area in February 2019. It was successfully tested, installed, and commissioned at the Spectroscopy and Coherent Scattering Instrument. DSSC is a high-speed, large-area, 2-D imaging detector system optimized for photon science applications in the energy range between 0.25 and 6 keV. The camera is based on direct conversion Si sensors and is composed of 1024 ×1024 pixels of hexagonal shape with a side length of 136 μm. The 256 application-specific integrated circuits (ASICs) provide full parallel readout, comprising analog filtering, digitization, and in-pixel data storage. In order to cope with the demanding X-ray pulse time structure of the EuXFEL, the DSSC provides a peak frame rate of 4.5 MHz. The first Mpixel camera is equipped with miniaturized silicon drift detector (MiniSDD) pixel arrays. The intrinsic response of the pixels and the linear readout limit the dynamic range but allow one to achieve noise values of about 60 electrons r.m.s. at the highest frame rate. The challenge of providing high-dynamic range (~10 4 photons/pixel/pulse) and single-photon detection simultaneously requires a nonlinear system front end, which will be obtained with the DEPFET active pixel technology foreseen for the advanced version of the camera. This technology will provide lower noise and a nonlinear response at the sensor level. This article describes the architecture of the whole detector system together with the main experimental results achieved up to now.

17 January 2024 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
AAAlexander Altmann
Alexander Altmann
TBThomas F. Bechteler
Thomas F. Bechteler
PLPeter Lechner
Peter Lechner
CFCarlo Fiorini
Carlo Fiorini
KNKirpal Nandra
Kirpal Nandra
A silicon drift detector module has been developed to be used in high time resolution X-ray spectroscopy. The module consists of a 19-cell silicon drift detector chip and three readout application-specific integrated circuits (ASIC). With respect to timing and energy resolution, the readout ASIC with its programmable setting parameters is characterized. Based on the results of this characterization, analytical rules for these setting parameters are established to obtain the optimum performance of the module. The performance of the module is verified by means of measurements. With the ascertained parameter values and selecting the available shaping time of 1.02 μs, a minimum time interval of 1.87 μs between pulses and an energy resolution of 176 eV at 5.9 keV and at a temperature of -30°C are achieved.

1 March 2008 in Compost Science & Utilization
Verified
Journal Article
Closed access
GDGetinet Desalegn
Getinet Desalegn
EBE. Binner
E. Binner
PLPeter Lechner
Peter Lechner
Performing compost quality assessment such as compost stability is quite necessary for rating the quality of horse manure and biowaste composts and meeting specific regulatory requirements on the composition and compost process. The aim of this study was to identify an appropriate feedstock composition for use in the production of high quality compost. The objectives were to (1) identify an appropriate feedstock composition (2) determine organic matter decomposition and humic acids (HA) development in various composts; (3) compare changes in temperature, C/N ratio and respiration activity, occurring during decomposition of organic matter; (4) evaluate phytotoxicity effects of the final compost on cress seed germination and growth. The above changes in physical, chemical and biological parameters were monitored during the laboratory composting process over a period of 20 weeks. Five organic waste blends of horse manure (HM) and biowaste (BW) were used. The results indicated that at the beginning of the experiment, the highest C/N ratio of 59 was recorded in the pure horse manure. This is attributed to the presence of higher amounts of bedding materials (wood chips and wheat straw). The degradation rate of pure HM was slower than that of BW and the degradation had not been completed by the end of the 20 weeks composting period. An ANCOVA with time as the covariate showed that pure BW was more significantly humified than pure HM (p<0.05). Consistently higher contents of HA and lower E4/E6 ratio were obtained in pure BW than in pure HM throughout the processes. Statistically significant difference (p<0.01) among treatments were found for the shoot fresh weight percentage (SFW%). Correlations between the latter and E4/E6 ratios were significant at (p<0.001). Chemical and biological changes indicated an increase in compost quality in correspondence with BW composition increment. Largely the 50/50 blend was not significantly different from other feedstocks (p<0.01) except from pure HM. It was therefore concluded that composting using a combination of HM and BW (50/50) could be used as an alternative method to pure HM composting.

22 September 2022 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Open access
PDF file
JIJohanna Irrgeher
Johanna Irrgeher
TBThomas Berger
Thomas Berger
ATAnastassiya Tchaikovsky
Anastassiya Tchaikovsky
CTCornelius Tschegg
Cornelius Tschegg
GGGhazaleh Gouya
Ghazaleh Gouya
TPThomas Prohaska
Thomas Prohaska
The potential of enriched Pb (204Pb) was assessed to monitor pathways of trace levels of Pb in the pg range within the human body via isotope pattern variation in situations where natural lead cannot be used as a tracer due to regulatory limitations. Isotope ratio measurements were accomplished by means of (multi-collector) inductively coupled plasma mass spectrometry including a comparison of single and multi-collector ICP-MS for low-level 204Pb assessment. Isotopic pattern results from a blend of a large quantity of the element with a natural isotopic composition and an enriched stable isotope at orders of magnitude lower levels pose a nontrivial analytical problem. Isotope pattern deconvolution was successfully applied as mathematical tool based on multiple linear regressions. The method allowed for deconvolving the isotope pattern from measured isotope ratios without knowing the quantities of different isotope sources incorporated and mixed into the sample at levels of < 1 pg 204Pb/g blood. The objective of this manuscript is to evaluate and summarize the analytical aspects for Pb isotope pattern deconvolution based on the results of a clinical trial, where a 204Pb-enriched isotope tracer was applied to investigate the bioavailability of orally applied Pb along with purified clinoptilolite tuff as potential supplement. This unique approach allows to reduce tracer amounts to harmless levels to human health, which are in accordance with the legal regulative to study enrichment levels of < 0.01% in human blood. Graphical abstract

1 April 2008 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
CZChen Zhang
Chen Zhang
PLPeter Lechner
Peter Lechner
GLGerhard Lutz
Gerhard Lutz
JTJohannes Treis
Johannes Treis
SWStefan Wölfel
Stefan Wölfel
SZShu Zhang
Shu Zhang

1 December 2024 in Journal of Instrumentation
Verified
Journal Article
Open access
DSD. Spreng
D. Spreng
KUK. Urban
K. Urban
Marco CarminatiMarco Carminati
Marco Carminati
FEF. Edzards
F. Edzards
CFCarlo Fiorini
Carlo Fiorini
SMS. Mertens
S. Mertens
Sterile neutrinos are hypothetical particles in the minimal extension of the Standard Model of Particle Physics. They could be viable dark matter candidates if they have a mass in the keV range. The Karlsruhe tritium neutrino (KATRIN) experiment, extended with a silicon drift detector focal plane array (TRISTAN), has the potential to search for keV-scale sterile neutrinos by measuring the kinematics of the tritium β-decay. The collaboration targets a sensitivity of 10-6 on the mixing amplitude sin2Θ. For this challenging target, a precise understanding of the detector response is necessary. In this work, we report on the characterization of electron backscattering from the detector surface, which is one of the main effects that influence the shape of the observed energy spectrum. Measurements were performed with a tandem silicon drift detector system and a custom-designed electron source. The measured detector response and backscattering probability are in good agreement with dedicated backscattering simulations using the Geant4 simulation toolkit.