View All Publications
11 May 2020 in The International Journal of Artificial Organs
Verified
Journal Article
Closed access
PDF file
SSShuya Shida
Shuya Shida
TMToru Masuzawa
Toru Masuzawa
MOMasahiro Osa
Masahiro Osa
Implantable ventricular assist devices are a type of mechanical circulatory support for assisting the pumping of the heart. Accurate estimation of the flow rate through such devices is critical to ensure effective performance. A novel method for estimating the flow rate using the passively stabilized position of a magnetically levitated impeller was developed by our group. However, the performance of the method is affected by the gravity vector, which depends on the patient’s posture. In this study, the effects of gravity on the flow estimation method are analyzed, and a compensation method is proposed. The magnetically levitated impeller is axially suspended and radially restricted by passive stability in a centrifugal blood pump developed by our group. The gravity effects were evaluated by analyzing the relationships between the radial position of the magnetically levitated impeller and the flow rate with respect to the gravity direction. Accurate estimation of the flow rate could not be achieved when the direction of gravity with respect to impeller was unknown. A mean absolute error of up to 4.89 L/min was obtained for flow rate measurement range of 0–5 L/min. However, analysis of the equilibrium of forces on the passively stabilized impeller indicated that the effects of gravity on the flow estimation could be compensated by performing additional measurements of the gravity direction with respect to impeller. The method for compensating the effects of gravity on the flow estimation should improve the performance of therapy with the implantable ventricular assist devices.

25 December 2020 in The International Journal of Artificial Organs
Verified
Journal Article
Closed access
PDF file
SSShuya Shida
Shuya Shida
TMToru Masuzawa
Toru Masuzawa
MOMasahiro Osa
Masahiro Osa
Implantable ventricular assist devices are used in heart failure therapy. These devices require real-time flow rate estimation for effective mechanical circulatory support. We previously developed a flow rate estimation method using the eccentric position of a magnetically levitated impeller to achieve real-time estimation. However, dynamic motion of the levitated impeller can compromise the method’s performance. Therefore, in this study, we investigated the effects of dynamic motion of the levitated impeller on the time resolution and estimation accuracy of the proposed method. The magnetically levitated impeller was axially suspended and radially restricted by the passive stability in a centrifugal blood pump that we developed. The dynamic motions of impeller rotation and whirling were analyzed at various operating conditions to evaluate the reliability of estimation. The vibration response curves of the impeller revealed that the resonant rotational speed was 1300–1400 revolutions per minute (rpm). The blood pump was used as a ventricular assist device with rotational speed (over 1800 rpm) sufficiently higher than the resonant speed. The rotor-dynamic forces on the impeller (0.03–0.14 N) suppressed the whirling motion of the impeller, indicating that the dynamic motion could be stable. Although the temporal responsiveness should be determined based on the trade-offs among the estimation accuracy and time resolution, the real-time estimation capability of the proposed method was confirmed.

31 October 2023 in The International Journal of Artificial Organs
Verified
Journal Article
Closed access
SSShuya Shida
Shuya Shida
KTKenichi Tsushima
Kenichi Tsushima
MOMasahiro Osa
Masahiro Osa
DTDaniel L Timms
Daniel L Timms
TMToru Masuzawa
Toru Masuzawa
Severe left ventricular failure can progress to right ventricular failure, necessitating alternatives to heart transplantation, such as total artificial heart (TAH) treatment. Conventional TAHs encounter challenges associated with miniaturization and hemocompatibility owing to their reliance on mechanical valves and bearings. A magnetically levitated TAH (IB-Heart) was developed, utilizing a magnetic bearing. The IB-Heart features a distinctive biventricular shunt channel situated between the flow paths of the left and right centrifugal blood pumps, simplifying and miniaturizing its control system. However, the impact of these shunt channels remains underexplored. This study aimed to investigate the effects of shunt flow on pump characteristics and assess the IB-Heart’s potential to regulate flow balance between systemic and pulmonary circulation. At a rotational speed of 2000 rpm and flow rate range of 0–10 L/min, shunt flow exhibited a minor impact, with a 1.4 mmHg (1.3%) effect on pump characteristics. Shunt flow variation of about 0.13 L/min correlated with a 10 mmHg pressure difference between the pumps’ afterload and preload conditions. This variance was linked to changes in the inlet flow rates of the left and right pumps, signifying the ventricular shunt structure’s capacity to mirror the function of an atrial shunt in alleviating pulmonary congestion. The IB-Heart’s ventricular shunt structure enables passive regulation of left-right flow balance. The findings establish a fundamental technical groundwork for the development of IB-Hearts and TAHs with similar shunt structures. The innovative coupling of centrifugal pumps and the resultant effects on flow dynamics contribute to the advancement of TAH technology.

1 January 2024 in International Journal of Affective Engineering
Verified
Journal Article
Open access
PDF file
YSYutaka Suzuki
Yutaka Suzuki
SSShuya Shida
Shuya Shida
YYYuto Yamamura
Yuto Yamamura
NTNobuyuki Terada
Nobuyuki Terada
Taste is perceived based on chemical and physical factors. The former includes taste and smell, while the latter includes texture, appearance, and sound. Physical factors have a considerable impact on the tastiness of solid foods. In this study, a quantitative evaluation is performed by analysing the sound of chewing for the ‘crispy’ sensation when chewing food. It is confirmed that the loudness increases and that many high-frequency components are included. The sharpness calculation results reveal that the sharpness value of a sample with a high sensory level is large. The results indicate a correlation exists between the shrillness of different sounds perceived by humans.

23 September 2026 in Biomedical Signal Processing and Control
Verified
Journal Article
Open access
SSShuya Shida
Shuya Shida
YSYutaka Suzuki
Yutaka Suzuki
TAToshinari Akimoto
Toshinari Akimoto
YKYoshihiro Kubota
Yoshihiro Kubota