Eghbal Amidi

Eghbal Amidi

Auto-generated profile, based on publicly available information

Eghbal Amidi

Washington Univ. in St. Louis (United States)

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2018 in Radiology
Verified
Journal Article
Closed access
SNSreyankar Nandy
Sreyankar Nandy
AMAtahar Mostafa
Atahar Mostafa
IHIan S. Hagemann
Ian S. Hagemann
MPMatthew A. Powell
Matthew A. Powell
EAEghbal Amidi
Eghbal Amidi
QZQuing Zhu Zhu
Quing Zhu Zhu
Purpose To assess transvaginal coregistered photoacoustic tomography (PAT) and pulse-echo US for diagnosis of ovarian cancer based on functional parameters provided by PAT. Materials and Methods Between February 2017 and December 2017, 26 ovarian masses from 16 participants were successfully imaged in vivo by multispectral photoacoustic imaging, including nine invasive epithelial ovarian cancers (six serous carcinomas and three endometroid adenocarcinomas), three other tumors (two borderline serous tumors and one sex cord-stromal tumor), and 14 benign and normal (hereafter referred to as benign/normal) ovaries. The relative total hemoglobin concentration (rHbT) and mean oxygen saturation (sO2) shown at PAT were used to characterize the ovaries identified at US. Results The average rHbT was 1.9 times higher for invasive epithelial cancers than for the benign/normal ovaries (P = .01). Additionally, the rHbT distribution was extensive in invasive epithelial cancers, but was scattered in benign/normal ovaries. However, the rHbT of two borderline serous tumors and one stromal tumor was in the same range as that of benign/normal ovaries. The mean sO2 of invasive epithelial cancers, and of the borderline and stromal tumors, was 8.2% lower than that of benign/normal ovaries (P = .003). Discussion Invasive epithelial ovarian cancers showed higher and extensive tumor vascularity and lower oxygen saturation than benign and normal ovaries. Two borderline noninvasive serous and one stromal tumor showed low oxygen saturation compared with benign and normal ovaries. ©RSNA, 2018 Online supplemental material is available for this article.

8 April 2019 in Biomedical Optics Express
Verified
Journal Article
Closed access
PDF file
EAEghbal Amidi
Eghbal Amidi
AMAtahar Mostafa
Atahar Mostafa
SNSreyankar Nandy
Sreyankar Nandy
GYGuang Yang
Guang Yang
WMWilliam Middleton
William Middleton
QZQuing Zhu Zhu
Quing Zhu Zhu
We report in this pilot study the diagnostic results of in vivo imaging of patients with ovarian lesions, using a co-registered photoacoustic and ultrasound (PAT/US) system. A total of 39 ovaries from 24 patients were imaged in vivo. PAT functional features, i.e., blood oxygen saturation (sO2) and relative total hemoglobin (rHbT), PAT image features, and PAT spectral features within a region of interest (ROI) in each ovarian tissue were extracted. To select the significant features, a t-test on each feature was performed, and the independent predictors were determined by evaluating correlation between each pair of predictors. To classify the ovarian lesions, we employed a generalized linear model (GLM) and a support vector machine (SVM). We used these classifiers first to distinguish benign/normal lesions from ovaries with invasive epithelial tumors and then to separate normal/benign lesions from all types of ovarian tumors. We developed classifiers once by inclusion of PAT functional features to assess the best diagnostic performance of the classifiers when multiple wavelengths data are available. Second time, we excluded the PAT functional features from the features set to evaluate the best diagnostic performance if only a single wavelength is available. Our results show that using functional features improves the classification performance, especially for distinguishing normal/benign ovarian lesions from all types of tumors. In this case, an area under ROC curve (AUC) of 0.92, 0.93 of testing data was achieved using a GLM and SVM classifier when functional features were included in the feature set while excluding these features resulted in an AUC of 0.89, 0.92, respectively.

23 March 2021 in Radiology
Verified
Journal Article
Closed access
XLXiandong Leng
Xiandong Leng
KUK. M. Shihab Uddin
K. M. Shihab Uddin
WCWilliam Chapman
William Chapman
HLHongbo Luo
Hongbo Luo
SKSitai Kou
Sitai Kou
QZQuing Zhu Zhu
Quing Zhu Zhu
Coregistered endorectal photoacoustic microscopy and US imaging quantified by a neural network demonstrated excellent differentiation between rectal tumor beds with residual cancers and those witho... Background Conventional radiologic modalities perform poorly in the radiated rectum and are often unable to differentiate residual cancer from treatment scarring. Purpose To report the development ...

19 November 2019 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
GYGuang Yang
Guang Yang
EAEghbal Amidi
Eghbal Amidi
WCWilliam C. Chapman
William C. Chapman
SNSreyankar Nandy
Sreyankar Nandy
AMAtahar Mostafa
Atahar Mostafa
QZQuing Zhu Zhu
Quing Zhu Zhu
Photoacoustic imaging (PAI) is an emerging technique that can provide high optical absorption contrast images at reasonable microscale resolution and clinically relevant depths.1 Several studies have established that optical absorption parameters are important biomarkers directly related to the tissue microvasculature, tumor angiogenesis, or tumor hypoxia.2 – 4 In general, PAI is classified into photoacoustic microscopy (PAM) and photoacoustic tomography (PAT).1 Previously, PAM and photoacoustic endoscopy have demonstrated the capability of detecting human colorectal cancer.5,6 However, the low imaging speed (limited by the laser repetition rate and scanning scheme), small imaging area, and moderate penetration depth created obstacles for clinical applications.

1 March 2019 in Photoacoustics
Verified
Journal Article
Open access
GYGuang Yang
Guang Yang
EAEghbal Amidi
Eghbal Amidi
SNSreyankar Nandy
Sreyankar Nandy
AMAtahar Mostafa
Atahar Mostafa
QZQuing Zhu Zhu
Quing Zhu Zhu
An optimized hand-held photoacoustic and ultrasound probe suitable for endo-cavity tumor subsurface imaging was designed and evaluated. Compared to previous designs, the prototype probe, consisting of four 1mm multimode optical fibers attached with 1.5mm diameter ball-shaped fiber tips sandwiched between a transvaginal ultrasound transducer and a custom-made sheath, demonstrated a higher light output and better beam homogeneity on tissue subsurface. The output power and fluence profile were simulated for different design parameters. A camera recorded fluence profiles through calibrated intralipid solution at various imaging depths. The light delivery efficiency was experimentally compared with and without the ball lenses, based on ex-vivo imaging of human colorectal cancer and in-vivo imaging of a palmar vein proximal to the human wrist. The simulations and experiments demonstrated that ball-shaped fiber tip design can achieve homogeneous fluence distribution on tissue subsurface with acceptable light output efficiency, suggesting its clinical potential for in-vivo endocavity imaging.

23 March 2021 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
GYGuang Yang
Guang Yang
EAEghbal Amidi
Eghbal Amidi
QZQuing Zhu Zhu
Quing Zhu Zhu
Ovarian cancer is the fifth most common cause of death due to cancer, and it is the deadliest of all gynecological cancers. Diagnosing ovarian cancer via conventional photoacoustic delay-and-sum beamforming (DAS) presents several challenges, such as poor image resolution and low lesion to background tissue contrast. To address these concerns, we propose an improved beamformer named lag-based delay multiply and sum combined with coherence factor (DMAS-LAG-CF). Simulations and phantom experiments demonstrate that compared with the conventional DAS, the proposed algorithm can provide 1.39 times better resolution and 10.77 dB higher contrast. For patient data, similar performance on contrast ratios has been observed. However, since the diagnostic accuracy between cancer and benign/normal groups is a significant measure, we have extracted photoacoustic histogram features of mean, kurtosis and skewness. DMAS-LAG-CF can improve cancer diagnosis with an AUC of 0.91 for distinguishing malignant vs. benign ovarian lesions when mean and skewness are used as features.