Norman Werther

Norman Werther

Auto-generated profile, based on publicly available information

Norman Werther

Technische Universität München

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 April 2024 in Fire Technology
Verified
Journal Article
Open access
PDF file
TEThomas Engel
Thomas Engel
NWNorman Werther
Norman Werther
This study is the first part of a larger investigation into the fire behaviour of green façades. In this study, the currently known international research status on this topic is presented and discussed. In addition, the flammability of green façades is investigated through 43 fire tests on a medium scale according to the SBI (Single Burning Item) test method EN 13823. The focus of the investigation was placed on climbing plants. A total of 25 different plant species were investigated. A comparison of the heat release rate of all the investigated vital plants shows similar behaviour. In the course of exposure, there are short peaks in the heat release rate. These peaks are “flare-ups” that occur when parts of the plants dry out due to exposure to the flame and then ignite. The plant species itself had no substantial influence on fire behaviour. Horizontal fire spread occurred to a very limited extent within the investigations of vital plants. They were self-extinguishing. The significant factor in the assessment of flammability is the moisture content of the plants. With dried plants, an abrupt heat release occurs at the beginning. Dried-out plants, as well as unmaintained plants with a high content of deadwood, represent the most critical case. Graphical Abstract

13 December 2022 in Fire Technology
Verified
Journal Article
Open access
PDF file
TEThomas Engel
Thomas Engel
NWNorman Werther
Norman Werther
This study investigates whether timber surfaces that are initially exposed to fire or partially protected timber components can lead to a more critical fire exposure on the façade. Five full-scale fire tests were carried out. Three tests with a square compartment (4.5 × 4.5 m2) and two with a double-width compartment (4.5 × 9 m2). The tests were conducted with a high fire load density (1085 MJ/m2). While the first test was carried out in a non-combustible compartment, the exposed timber surfaces were subsequently increased in the other tests. The measured compartment gas temperature, heat release rate, temperature on the façade, flame heights along the façade, heat flux and velocities along the façade are presented in this publication. The influence of exposed or only initially protected timber surfaces on the fire impact on the façade is investigated with the help of these results. Finally, these findings are presented and compared with the results of other internationally conducted fire tests from literature. Additional structural fire load leads to an increase in temperatures on the façade. However, there is no significant difference in flame height between the tests. Another result was that an exposed mass timber ceiling leads to higher heat fluxes on the façade than an exposed mass timber wall. Graphical Abstract

22 October 2021 in Fire Technology
Verified
Journal Article
Open access
PDF file
TEThomas Engel
Thomas Engel
NWNorman Werther
Norman Werther
This study investigates five fire stop variants used to limit the spread of fire on wooden façades. For this purpose, five fire tests using various types of wooden façade claddings and different fire stops were conducted as full-scale tests and compared to the existing findings. The influences and interactions between the material qualities of the external wall behind the façade cladding, the construction type of the wooden façade cladding, the design of the substructure, the depth of the ventilation gap, and the design of the fire stops were investigated. In evaluating the fire stops, the design of the interior corners, the joint design, and the influence of thermal expansion were examined. Finally, design proposals for the design of fire stops at wooden façades in order to limit the spread of fire were derived based on this evaluation. The outlook presents further needs that need to be investigated in the future in order to clarify undiscussed aspects or points that were ultimately not evaluated within the scope of this study. Graphical Abstract

5 June 2020 in Bautechnik
Verified
Journal Article
Closed access
PDF file
TEThomas Engel
Thomas Engel
NWNorman Werther
Norman Werther


1 May 2021 in Bautechnik
Verified
Journal Article
Closed access
PDF file
TEThomas Engel
Thomas Engel
KMKatharina Moosmüller
Katharina Moosmüller
NWNorman Werther
Norman Werther