Gabriel Junquetti Mattos

Gabriel Junquetti Mattos

Auto-generated profile, based on publicly available information

Gabriel Junquetti Mattos

Department of Inorganic and Analytical Chemistry, University of Geneva, Quai Ernest-Ansermet 30, CH-1211, Geneva, Switzerland

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2019 in Talanta
Verified
Journal Article
Closed access
JCJoão H. Coelho
João H. Coelho
AEAna P.P. Eisele
Ana P.P. Eisele
CVCamila F. Valezi
Camila F. Valezi
GMGabriel J. Mattos
Gabriel J. Mattos
JSJéseka G. Schirmann
Jéseka G. Schirmann
ESElen R. Sartori
Elen R. Sartori

1 October 2019 in Bioelectrochemistry
Verified
Journal Article
Closed access
GMGabriel J. Mattos
Gabriel J. Mattos
JMJaqueline T. Moraes
Jaqueline T. Moraes
EBEduardo C.M. Barbosa
Eduardo C.M. Barbosa
PCPedro H.C. Camargo
Pedro H.C. Camargo
RDRobert F.H. Dekker
Robert F.H. Dekker
ESElen R. Sartori
Elen R. Sartori

26 January 2017 in Electroanalysis
Verified
Journal Article
Closed access
PDF file
GMGabriel Junquetti Mattos
Gabriel Junquetti Mattos
JSJessica Scremin
Jessica Scremin
CSCarlos Alberto Rossi Salamanca‐Neto
Carlos Alberto Rossi Salamanca‐Neto
ESElen Romão Sartori
Elen Romão Sartori

11 February 2022 in Applied Biochemistry and Biotechnology
Verified
Journal Article
Closed access
PDF file
GMGabriel J. Mattos
Gabriel J. Mattos
JSJéseka G. Schirmann
Jéseka G. Schirmann
CSCarlos A. R. Salamanca-Neto
Carlos A. R. Salamanca-Neto
RDRobert F. H. Dekker
Robert F. H. Dekker
ABAneli M. Barbosa-Dekker
Aneli M. Barbosa-Dekker
ESElen R. Sartori
Elen R. Sartori

24 July 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
DSDogan Sinar
Dogan Sinar
GMGabriel Junquetti Mattos
Gabriel Junquetti Mattos
George KnopfGeorge Knopf
George Knopf
Significant fluctuations in body fluid pH can indicate the onset of infection or a chronic condition. In this paper, a hydrogel-activated circular discrete interdigitated capacitive (D-IDC) biosensor is introduced for monitoring the acidity of biological fluids. The pH-sensitive transducer is a thin biocompatible chitosan / polyvinyl alcohol hydrogel disk positioned at the center of a multi-terminal D-IDC comprised of numerous distinct circular conductive electrodes covering the active sensing area. The D-IDC is printed on Nylon-66 filter paper that has been coated with a thin layer of polydimethylsiloxane (PDMS). The circular electrode pattern is printed on the PDMS surface using nontoxic graphene / carboxymethyl cellulose (G-CMC) aqueous suspensions as the electrically conductive ink. A thin polymer passivation layer is then spin coated on the surface of the G-CMC conductive electrodes to prevent an electrical short with the liquid filled hydrogel transducer. The pH level of the fluid causes the centrally located hydrogel transducer to swell/de-swell over the circular electrodes producing an incremental change in the measured capacitance. A prototype comprised of seven electrode pairs is fabricated and experimentally tested under controlled conditions using phosphate buffer solutions (PBS) with varying pH. The operational and analytical parameters of the hydrogel-activated biosensor are evaluated in terms of measured capacitance. The prototype sensor demonstrates acceptable repeatability (SD < 0.4%) and reproducibility (SD < 5.8%). Sensor resolution can be modified by reducing the physical size of the electrode micro-traces used in the D-IDC design and increasing the number electrode pairs.

1 March 2022 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
GMGabriel J. Mattos
Gabriel J. Mattos
GMGustavo G. Marcheafave
Gustavo G. Marcheafave
WRWilliam H. Roldán
William H. Roldán
MMMiguel J. Mattos
Miguel J. Mattos
FPFabiana M. de Paula
Fabiana M. de Paula
ESElen R. Sartori
Elen R. Sartori