18 December 2020 in IEEE Industrial Electronics Magazine
The limitations of the thermal, vibration, or electrical monitoring of electric machines such as false indications, low sensitivity, and difficulty of fault interpretation have recently been exposed. This has led to a shift in the direction in research toward applying new techniques for improving the reliability of condition monitoring. With the changing environment, the purpose of this article is to provide an overview of the recent trends in the industrial demand and research activity in condition monitoring technology. The new developments in insulation testing, electrical testing, flux analysis, transient analysis, and fault prognostics are summarized. The challenges and recommendations for future work for the new technologies are also explored to help support target research and development efforts according to industrial needs.
15 August 2017 in IEEE Transactions on Industry Applications
Partial-discharge (PD) testing has long been an important tool for assessing the condition of the high-voltage insulation in motor and generator stator windings. In the past several years, many motors have been powered from inverters, which facilitate variable-speed motor operation. The most common drive used today is the voltage-source pulse-width modulation (VS-PWM) type. VS-PWM drives rated up to 13.8 kV are becoming more common in natural gas processing plants, as well as in other petrochemical facilities. Such drives generate high-voltage impulses in the kilovolt range with rise times in the submicrosecond range. These impulses are a form of severe electrical interference that can make difficult the online detection of PD (with magnitudes 1000 times smaller) due to the overlapping frequency content in PD and in the impulses. Thus, PD detection on medium-voltage VS-PWM systems has been a challenge in spite of the serious stator winding insulation aging that such drives may cause to these motors. This paper discusses the stator winding failure mechanisms that produce PD, including the insulation problems that VS-PWM drives can accelerate. A research project that lasted several years is reviewed. This project culminated in a prototype online PD monitoring system suitable for motors fed by VS-PWM drives.
18 April 2019 in IEEE Transactions on Industry Applications
Damper bars are often used in high output salient pole synchronous motor (SM) rotors for motor starting and stabilization of performance. Several cases of broken damper bars in the rotor of SMs that lead to motor starting failure and/or forced outage have recently been reported. However, detection of damper bar failures is difficult, since the damper bars are active only under the starting or load transients. Damper bar testing in the field currently relies on off-line visual inspection, and there is no means available for detecting failures on-line. In this paper, a new method for detecting damper bar failures based on the analysis of airgap search coil measurements under the starting transient is proposed. Since airgap search coils are being increasingly installed in large SMs for detecting field winding short circuits, the proposed method can be implemented without additional hardware. The effectiveness of the proposed method is verified with 2 dimensional finite element analysis and experimental testing on a custom-built 30 kW salient pole SM under controlled fault conditions. It is shown that the proposed method can provide reliable and sensitive detection of broken damper bars whenever the motor is started at low additional cost. The off-line single phase rotation test is also shown to provide reliable monitoring of damper bar condition.
13 January 2022 in IEEE Transactions on Industry Applications
Partial discharge (PD) due to high dv/dt pulsewidth modulation has been identified as one of the leading causes of insulation failure in low voltage (LV) variable frequency drive (VFD) fed motors with random wound stator windings. With the recent increase in electrical stress with faster risetime wide bandgap power semiconductor devices and higher dc link voltage for higher efficiency and power density of the system, PD-induced insulation failures are expected to increase. Since LV motor insulation is not resistant to PD, an increasing number of VFD motors are being qualified for PD-free operation. However, the PD inception voltage of qualified motors decreases with insulation aging making LV motors susceptible to failure. In this article, an offline standstill test method is proposed for automated inverter-embedded PD testing under impulse excitation. The main concept is to perform the impulse PD test using the VFD at increased voltage levels for providing advanced warning of PD activity for preventing forced outage of VFD motors. Options for application of increased impulse test voltage and automated detection of PD for implementing the proposed concept are presented. Testing on an 800 V VFD driven motor shows that the proposed method can provide automated impulse PD testing whenever the motor is at standstill to warn the end user of impending PD activity that can lead to failure.
15 March 2019 in IEEE Transactions on Energy Conversion
Interturn insulation failure in the field winding of synchronous motors is a common problem that can lead to degradation in performance and accelerated wear of motor components. Existing off-line tests for detecting this fault are known to be unreliable and inconvenient to perform, as they require motor disassembly. On-line monitoring based on airgap flux monitoring has been proven to be successful, but could lack sensitivity for cases where the number of turns per pole is large. In addition, field winding turn shorts can be intermittent depending on the centrifugal force and could be unobservable at standstill or under steady state operation. Therefore, monitoring of the turn faults under standstill and starting conditions with high sensitivity and without motor disassembly is desirable. In this paper, the detection of field winding short circuits for salient pole synchronous motors based on an airgap search coil under the starting transient, and new methods for standstill testing without motor disassembly are proposed. 2D FE analysis and experimental testing on a 30 kW motor are given to verify the claims made. It is shown that the proposed set of tests can provide sensitive and reliable detection of field winding short circuits under standstill and starting conditions.
6 February 2018 in IEEE Transactions on Industry Applications
The reliability of medium voltage (MV) motors used for driving pumps, fans, and other loads in the power generation industry is critical for continued power production. Periodic testing of stator winding insulation, which is the most vulnerable component in MV motors, is an essential part of predictive maintenance for preventing unplanned reduction in the power generation capability. Korea Electric Power Corporation (KEPCO) Research Institute's 17+ years of experience on predictive maintenance of stator insulation for MV motors is presented in this paper. KEPCO's stator insulation test program and statistics of test records are summarized, and cases of recent turn and phase insulation failures that resulted in motor forced outages are investigated. Analysis of the turn or phase insulation failures and insulation test records performed on the failed motors show that it is difficult to predict turn or phase insulation failures with the insulation tests currently performed. Turn or phase insulation test methods are summarized and evaluated based on the findings of the investigation to help target future research efforts towards industrial needs.