Sang Bin Lee

Sang Bin Lee

Auto-generated profile, based on publicly available information

Sang Bin Lee

Department of Electrical Engineering Korea, University Seoul, Seoul, South Korea

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 December 2020 in IEEE Industrial Electronics Magazine
Verified
Journal Article
Closed access
SLSang Bin Lee
Sang Bin Lee
GSGreg C. Stone
Greg C. Stone
Jose Alfonso Antonino DaviuJose Alfonso Antonino Daviu
Jose Alfonso Antonino Daviu
Konstantinos N. GyftakisKonstantinos N. Gyftakis
Konstantinos N. Gyftakis
ESElias G Strangas
Elias G Strangas
Carlos A. PlateroCarlos A. Platero
Carlos A. Platero
The limitations of the thermal, vibration, or electrical monitoring of electric machines such as false indications, low sensitivity, and difficulty of fault interpretation have recently been exposed. This has led to a shift in the direction in research toward applying new techniques for improving the reliability of condition monitoring. With the changing environment, the purpose of this article is to provide an overview of the recent trends in the industrial demand and research activity in condition monitoring technology. The new developments in insulation testing, electrical testing, flux analysis, transient analysis, and fault prognostics are summarized. The challenges and recommendations for future work for the new technologies are also explored to help support target research and development efforts according to industrial needs.

15 December 2017 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
SKSuneel Kumar Kommuri
Suneel Kumar Kommuri
SLSang Bin Lee
Sang Bin Lee
Kalyana Chakravarthy VeluvoluKalyana Chakravarthy Veluvolu
Kalyana Chakravarthy Veluvolu
In general, permanent magnet synchronous motor (PMSM) drives require four sensors (one position, one DC-link voltage and at least two current sensors) to obtain a good dynamic control performance. If an unpredictable fault occurs in any of these sensors, the performance of the drive deteriorates or even become unstable. Most of the existing works are limited to fault diagnosis (FD) of one or two sensors due to complexity. Therefore, to provide a continuous drive operation regardless of any of the sensor faults, an advanced fault-tolerant control (FTC) scheme that comprises of higher-order sliding mode (HOSM) based observers and controllers is proposed. Two HOSM observers and one Luenberger observer (LO) are designed to generate the respective residuals and provide the detection of all sensor faults. Moreover, HOSM controllers are developed to ensure finite-time convergence of the error trajectories after the fault reconfiguration. The proposed FTC scheme reduces the existing chattering phenomenon with good performance in terms of convergence speed and steady-state error. Evaluation results on a three-phase PMSM are presented to validate the effectiveness of the proposed FTC approach.

14 December 2018 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
YPYonghyun Park
Yonghyun Park
DADaniel Fernández Alonso
Daniel Fernández Alonso
SLSang Bin Lee
Sang Bin Lee
DHDoosoo Hyun
Doosoo Hyun
MJMyung Jeong
Myung Jeong
FBFernando Briz
Fernando Briz
Rotor eccentricity and local demagnetization in permanent magnet synchronous motors (PMSMs) increases unbalanced magnetic pull and motor vibration resulting in accelerated aging of motor components. If the asymmetry in the rotor remains undetected, it can increase in severity, and increase the risk of stator-rotor contact, which causes forced outage of the motor and driven process. Detection of PMSM rotor asymmetry currently relies on off-line testing and on-line vibration/current spectrum analysis. However, they are inconvenient or cannot provide reliable detection as they are influenced by other mechanical non-idealities in the motor or load. In this paper, the feasibility of using the signals from analog Hall-effect field sensors for detecting eccentricity and local demagnetization is investigated. It is shown that Hall sensors present in machines for motion control can be used for measuring the variation in the flux inside the motor due to rotor magnetic asymmetry with minimal or no hardware modifications. 3-dimensional (3D) finite element analysis (FEA) and experimental results performed on an interior PMSM (IPMSM) show that the proposed method can provide sensitive and reliable detection of dynamic/mixed eccentricity and local PM demagnetization.

20 November 2018 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
YPYonghyun Park
Yonghyun Park
CYChanseung Yang
Chanseung Yang
JKJongwan Kim
Jongwan Kim
HKHEONYOUNG KIM
HEONYOUNG KIM
SLSang Bin Lee
Sang Bin Lee
GCGerard-Andre Capolino
Gerard-Andre Capolino
Monitoring of induction motor faults based on stray flux measurement has been investigated by many researchers due to its potential benefits in cost and simplicity. Although it was shown that flux based monitoring can provide sensitive fault detection comparable to that of motor current signature analysis (MCSA), the lack of “remote” monitoring capability has limited its practical use. The performance and reliability of stray flux-based detection of induction motor rotor cage faults is evaluated in this paper. It is shown for the first time in this work that spectrum analysis of the radial stray flux can provide reliable detection of rotor faults immune to the influence of rotor axial air ducts, which is the most common cause of false rotor fault alarms. The reliability and sensitivity of stray flux based rotor fault detection is demonstrated through experimental testing on laboratory and 6.6 kV field motors.

16 June 2021 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
MRMuhammad Saad Rafaq
Muhammad Saad Rafaq
HLHyeonjun Lee
Hyeonjun Lee
YPYonghyun Park
Yonghyun Park
SLSang Bin Lee
Sang Bin Lee
DADaniel Fernández Alonso
Daniel Fernández Alonso
FBFernando Briz
Fernando Briz
There has been active research in fault diagnosis of permanent magnet synchronous motors (PMSMs) with the recent increase in reliability-critical PMSM applications. Most of the research efforts are focused on the motor current signature analysis (MCSA), as it allows remote online detection of the rotor and load defects using the current measurement available in the drive. A critical limitation of MCSA or vibration analysis is their inability to distinguish the type of rotor or load defect. It is crucial for the maintenance engineer to identify the type of defect since the course of action for continued operation differs depending on the fault. In this letter, a simple automated test method for identifying mass unbalance using vibration measurement commonly available in motor drive systems is proposed. The effectiveness of the proposed method is verified on a PMSM under emulated PM demagnetization, dynamic eccentricity, and mass unbalance conditions.

15 April 2019 in IEEE Transactions on Industry Applications
Verified
Journal Article
Open access
YPYonghyun Park
Yonghyun Park
CYChanseung Yang
Chanseung Yang
SLSang Bin Lee
Sang Bin Lee
DLDong-myung Lee
Dong-myung Lee
DADaniel Fernández Alonso
Daniel Fernández Alonso
FBFernando Briz
Fernando Briz
On-line monitoring and diagnostics of permanent magnet synchronous motors (PMSM) is becoming important with the increasing demand in PMSM applications. Most of the research effort focuses on motor current signature analysis (MCSA) as it can provide remote, on-line monitoring at low cost. However, all types of defects that produce asymmetries in the PMSM rotor or load produce identical rotor rotational frequency components. This is a serious limitation when applying MCSA since it can produce false indications and degrade the sensitivity of fault detection. The requirement of complex time-frequency analysis techniques is another limitation of MCSA for applications with speed variations. In this paper, the feasibility of using analog Hall sensor signals to complement MCSA for detection and classification of rotor and load related defects is investigated. It is shown that Hall sensors installed in machines for initial rotor position estimation can be used with minimal hardware modifications, to detect and classify signatures produced by the rotor and load for cases where MCSA fails, even during transient conditions. Experimental testing performed on an IPMSM under eccentricity, local demagnetization, and load unbalance conditions show that the reliability and sensitivity of fault detection in PMSM systems can be improved at low added cost.