Garry Rumbles

Garry Rumbles

Auto-generated profile, based on publicly available information

Garry Rumbles

Department of Chemistry, University of Colorado Boulder, Boulder, CO, USA

Research Focus & Metrics

Academic Career Length

46Years (1981-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2006 in Nature Materials
Verified
Journal Article
Closed access
GSGregory D. Scholes
Gregory D. Scholes
GRGarry Rumbles
Garry Rumbles

21 November 2014 in ACS Nano
Verified
Journal Article
Closed access
KWKonrad Wojciechowski
Konrad Wojciechowski
SSSamuel D. Stranks
Samuel D. Stranks
AAAntonio Abate
Antonio Abate
GSGolnaz Sadoughi
Golnaz Sadoughi
ASAditya Sadhanala
Aditya Sadhanala
HSHenry J. Snaith
Henry J. Snaith

1 February 2007 in Analytical Chemistry
Verified
Journal Article
Open access
NBNoël Boens
Noël Boens
WQWenwu Qin
Wenwu Qin
NBNikola Basarić
Nikola Basarić
JHJohan Hofkens
Johan Hofkens
MAMarcel Ameloot
Marcel Ameloot
AMAtsushi Miura
Atsushi Miura
A series of fluorophores with single-exponential fluorescence decays in liquid solution at 20 °C were measured independently by nine laboratories using single-photon timing and multifrequency phase and modulation fluorometry instruments with lasers as excitation source. The dyes that can serve as fluorescence lifetime standards for time-domain and frequency-domain measurements are all commercially available, are photostable under the conditions of the measurements, and are soluble in solvents of spectroscopic quality (methanol, cyclohexane, water). These lifetime standards are anthracene, 9-cyanoanthracene, 9,10-diphenylanthracene, N-methylcarbazole, coumarin 153, erythrosin B, N-acetyl-l-tryptophanamide, 1,4-bis(5-phenyloxazol-2-yl)benzene, 2,5-diphenyloxazole, rhodamine B, rubrene, N-(3-sulfopropyl)acridinium, and 1,4-diphenylbenzene. At 20 °C, the fluorescence lifetimes vary from 89 ps to 31.2 ns, depending on fluorescent dye and solvent, which is a useful range for modern pico- and nanosecond time-domain or mega- to gigahertz frequency-domain instrumentation. The decay times are independent of the excitation and emission wavelengths. Dependent on the structure of the dye and the solvent, the excitation wavelengths used range from 284 to 575 nm, the emission from 330 to 630 nm. These lifetime standards may be used to either calibrate or test the resolution of time- and frequency-domain instrumentation or as reference compounds to eliminate the color effect in photomultiplier tubes. Statistical analyses by means of two-sample charts indicate that there is no laboratory bias in the lifetime determinations. Moreover, statistical tests show that there is an excellent correlation between the lifetimes estimated by the time-domain and frequency-domain fluorometries. Comprehensive tables compiling the results for 20 (fluorescence lifetime standard/solvent) combinations are given.

11 December 2009 in Nano Letters
Verified
Journal Article
Closed access
SDSmita Dayal
Smita Dayal
NKNikos Kopidakis
Nikos Kopidakis
DODana C. Olson
Dana C. Olson
DGDavid S. Ginley
David S. Ginley
GRGarry Rumbles
Garry Rumbles

1 December 2013 in Progress in Polymer Science
Verified
Journal Article
Closed access
FKFelix Peter Vinzenz Koch
Felix Peter Vinzenz Koch
JRJonathan Rivnay
Jonathan Rivnay
SFSam Foster
Sam Foster
CMChristian Müller
Christian Müller
JDJonathan M. Downing
Jonathan M. Downing
NSNatalie Stingelin
Natalie Stingelin

24 September 2003 in The Journal of Physical Chemistry B
Verified
Journal Article
Closed access
MJMarcus Jones
Marcus Jones
Jovan M. NedeljkovićJovan M. Nedeljković
Jovan M. Nedeljković
RERandy J. Ellingson
Randy J. Ellingson
ANArthur J. Nozik
Arthur J. Nozik
GRGarry Rumbles
Garry Rumbles