30 September 2020 in PLOS ONE
A novel cardiac motion correction algorithm has been introduced recently. Unlike other segmentation-based approaches it is fully automatic and capable of correcting motion artifacts of myocardial wall and other moving structures as well as coronary arteries of the heart. In addition, it requires raw data of only less than a single rotation for motion estimation and correction, which is a significant advantage from the perspective of x-ray exposure and workflow. The aim of this study is to explore the capability of the proposed method through phantoms and in-vivo experiments. Motion correction of coronary arteries and other heart structures including myocardial wall is the main focus of the evaluation. First, we provide a brief introduction to the concept of the motion correction algorithm. Next we address the procedure of our studies using an XCAT phantom and commercially available physical phantoms. Results of XCAT phantom demonstrate that our solution significantly improves the structural similarity of coronary arteries compared to FBP (proposed: 0.94, FBP: 0.77, p<0.001). Besides, it provides significantly lower root mean square error (proposed: 20.27, FBP: 25.33, p = 0.01) of the whole heart image. Mocomo phantom study shows that the proposed method improves the visualization of coronary arteries estimated based on motion score (1: worst, 5: best) from two experienced radiologists (proposed: 3.5, FBP: 2.1, p<0.001). The results of these phantom studies reveal that the proposed has a great potential in handling motion artifacts of other heart structures as well as coronary arteries. Finally, we provide the results of in-vivo animal and human studies. The 3D and 4D heart images show a consistently superior performance in the visualization of coronary arteries along with myocardial wall and other cardiothoracic structures. Based on these findings of our studies, we are of the opinion that our solution has a considerable potential to improve temporal resolution of cardiac CT imaging. This would open the door to innovations in structural or functional diagnosis of the heart.
19 November 2020 in Journal of the Korean Physical Society
Pediatric dosimetry requires extra attention as young children are three times more sensitive to radiation than the average population. Soft tissues of patients absorb low-energy photons without affecting useful diagnostic information. X-ray filters can decrease the exposure dose of radiation by removing low-energy photons from the X-ray beam. Several studies have dealt with the advantages of a conventional filter, copper (Cu), in pediatric digital X-ray radiography. Only a few studies, however, have examined the use of molybdenum (Mo) filters and their impact on the radiation dose and image quality in pediatric digital X-ray imaging. In this study, we investigated the impact of a Mo filter on the image quality and the entrance surface exposure (ESE) in pediatric X-ray imaging and assessed the potential of additional dose reduction compared to a conventional Cu filter. The performance of the Mo filter was investigated and compared with that of Cu filter. Two types of phantoms were used: a customized quantitative phantom (Phantom A) for quantitative comparison and a computational anthropomorphic extended cardiac-torso (XCAT) phantom for qualitative comparison. A clinical radiography system was modeled, and the clinical setting for pediatric chest X-ray imaging was considered. Geant4 simulations using Monte Carlo toolkits were performed to obtain the images for pediatric chest X-ray examinations. Quantitative and qualitative comparisons using the quantitative phantom (Phantom A) and the XCAT phantom, respectively, were performed for both filters. From the customized quantitative phantom study, the ESE for the Mo filter was compared with that for the Cu filter when contrast-to-noise ratio (CNR) was equal. In addition, to validate our Monte Carlo model, we compared simulated and experimentally acquired images. From the results, the ESE for the Cu filter was 22.62 μGy while the ESE for the Mo filter was 18.18 μGy for 5-mm soft tissue. The use of a Mo filter results in a reduction in the dose by 19.60%. From the XCAT phantom study, the image for the Mo filter was superior to that for Cu filter in terms of noise and recognition of blood vessels. The performance characteristics of the Mo filter were evaluated in terms of image quality and radiation dose by comparing those characteristics to the ones for a conventional Cu filter. Our results demonstrated that the use of the Mo filter can significantly reduce the radiation dose. Based on this result, Mo filters are recommended for use in pediatric digital X-ray imaging.