A novel cardiac motion correction algorithm has been introduced recently. Unlike other segmentation-based approaches it is fully automatic and capable of correcting motion artifacts of myocardial wall and other moving structures as well as coronary arteries of the heart. In addition, it requires raw data of only less than a single rotation for motion estimation and correction, which is a significant advantage from the perspective of x-ray exposure and workflow. The aim of this study is to explore the capability of the proposed method through phantoms and in-vivo experiments. Motion correction of coronary arteries and other heart structures including myocardial wall is the main focus of the evaluation. First, we provide a brief introduction to the concept of the motion correction algorithm. Next we address the procedure of our studies using an XCAT phantom and commercially available physical phantoms. Results of XCAT phantom demonstrate that our solution significantly improves the structural similarity of coronary arteries compared to FBP (proposed: 0.94, FBP: 0.77, p<0.001). Besides, it provides significantly lower root mean square error (proposed: 20.27, FBP: 25.33, p = 0.01) of the whole heart image. Mocomo phantom study shows that the proposed method improves the visualization of coronary arteries estimated based on motion score (1: worst, 5: best) from two experienced radiologists (proposed: 3.5, FBP: 2.1, p<0.001). The results of these phantom studies reveal that the proposed has a great potential in handling motion artifacts of other heart structures as well as coronary arteries. Finally, we provide the results of in-vivo animal and human studies. The 3D and 4D heart images show a consistently superior performance in the visualization of coronary arteries along with myocardial wall and other cardiothoracic structures. Based on these findings of our studies, we are of the opinion that our solution has a considerable potential to improve temporal resolution of cardiac CT imaging. This would open the door to innovations in structural or functional diagnosis of the heart.
17 December 2012 in Psychiatry and Clinical Neurosciences
Aim Attention deficit has been reported in both schizophrenia patients and patients with major depressive disorder (MDD). The aim of this study was to elucidate the deficits in sustained attention and associated neural network dysfunctions in schizophrenia patients and MDD patients, and to investigate the difference between the two patient groups. Methods Twelve schizophrenia patients, 12 patients with non‐psychotic MDD, and 12 healthy control subjects participated in this study. A sustained attention to response task (SART) was used to measure attention capacity. Cerebral blood flow (CBF) during attention tasks was measured using H215O positron emission tomography. Statistical parametric mapping and analysis of covariance were performed to compare the behavioral performance and CBF changes during SART among three groups. Results Behavioral performances were not significantly different among the three groups except for an increased commission error rate in the schizophrenia group. Regional CBF during SART was significantly reduced in the left inferior frontal gyrus, the left cuneus, and the right superior parietal lobule and increased in the right superior frontal gyrus and the right cuneus in the schizophrenia group compared to the healthy control group. In the MDD group, neither significant regional CBF difference nor behavioral deficit was found compared to the healthy control group. Conclusion Behavioral performance deficit and perfusion changes in the prefrontal and parietal cortices during SART were observed only in the schizophrenia group. Prefrontal and parietal network dysfunction for sustained attention may be involved in the pathophysiology of schizophrenia.
Adenofibroma is a benign tumor composed histologically of epithelial elements and mesenchymal stroma. Carcinosarcoma is a malignant neoplasm that contains elements of carcinoma and sarcoma. Carcinosarcoma arising from adenofibroma of the uterus has never been reported in the English literature. We report a case of a 56-year-old woman who complained vaginal spotting persisting for several months. We describe here for the first time a case of malignant transformation of uterine endometrial adenofibroma into carcinosarcoma that was depicted as a multilocular cystic lesion with enhancing solid portions and stalk-like structure between the myometrium and endometrial mass.
Ultrathin layered crystals of coordinated chromium(III) are promising not only as two-dimensional (2D) magnets but also as 2D near-infrared (NIR) emitters owing to long-range spin correlation and efficient transition between high and low-spin excited states of Cr3+ ions. In this study, we report on dual-band NIR photoluminescence (PL) of CrPS4 and show that its excitonic emission bifurcates into fluorescence and phosphorescence depending on thickness, temperature and defect density. In addition to the spectral branching, the biexponential decay of PL transients, also affected by the three factors, could be well described within a three-level kinetic model for Cr(III). In essence, the PL bifurcations are governed by activated reverse intersystem crossing from the low to high-spin states, and the transition barrier becomes lower for thinner 2D samples because of surface-localized defects. Our findings can be generalized to 2D solids of coordinated metals and will be valuable in realizing novel magneto-optic functions and devices.