4 July 2017 in IEEE Transactions on Power Delivery
This paper presents (i) an equivalent model of the half-bridge modular multilevel converter (HB-MMC), (ii) a hybrid CPU/FPGA-based architecture for real-time simulation of electromagnetic transients of systems which include HB-MMC and (iii) a modified odd-even bubble sorting method for voltage balancing of MMC sub-module capacitors. The Adam-Bashforth (AB) method is used for numerical integration of the model. AB method provides a constant admittance matrix of the HB-MMC and thus reduces computational burden. The CPU/FPGA-based architecture is optimized to obtain maximum parallelism of the HB-MMC model implementation, adopting a floating-point computational engine. In this architecture, the CPU functions are performed by an RTDS platform. The modified sorting method re-arranges the sorting output results to address the difficulties of parallel sorting process implementation. Performance and accuracy of the MMC model and the hybrid CPU/FPGA-based architecture are evaluated based on a set of case studies on a 401-level HB-MMC-based HVDC station and verified based on off-line simulation results in the PSCAD/EMTDC environment.
25 August 2021 in IEEE Journal of Solid-State Circuits
Autonomous-driving features necessitate a fault-tolerant (FT) power-management unit in 48-V automotive applications. This article presents a monolithic single-phase closed-loop masterless FT four-to-one hybrid Dickson converter IC for high-conversion-ratio 48-V automotive multi-phase applications. The chip includes: 1) a mixed-signal droop-based valley-current ON-time quasi-fixed-frequency control, which enables masterless multi-phase operation capability; 2) single-point short-circuit fault and open-circuit fault detection and blocking of any power switches or flying capacitors; 3) an optimized high-voltage (HV) power stage with fully integrated flying-capacitor-sourced gate drivers without any external bootstrap capacitors; 4) a glitch-free cross-coupled bootstrapped HV level shifter; and 5) a dual-leg bidirectional closed-loop current-sensing circuit optimized for the hybrid Dickson topology. The design was fabricated in a 0.13- $\mu \text{m}$ 90-V automotive silicon-on-insulator (SOI) bipolar-CMOS–DMOS (BCD) process. The measured results confirm the operation over 20–60-V input, 3.3-V nominal output, 3-A maximum load, and 320-kHz effective switching frequency within the automotive-grade −40 °C–+125 °C ambient temperature. The design achieves above 90% measured efficiency at maximum conversion ratio and load at room temperature. A three-phase system is used to evaluate and confirm the fault-blocking capability and continuous power delivery upon detection of a fault.
8 September 2020 in IEEE Transactions on Power Electronics
Autonomous-driving features have introduced safety-critical processor modules. A 48-V network has been developed to enable efficient power distribution. A fault-tolerant high-voltage power management unit is required to ensure continuous power delivery to critical loads. This paper compares the cost and efficiency penalty of accommodating the fault-tolerant capability in common dc-dc topologies. The comparison is verified using a 0.13-um high-voltage automotive Bipolar-CMOS-DMOS SMARTMOS technology in a Cadence simulation environment. Besides, a quantitative reliability assessment of the single-phase and multi-phase configurations is presented. This has led to the selection of the hybrid Dickson topology, which has the best electrical performance and comparable cost and reliability among all for high-conversion-ratio fault-tolerant 48-V automotive application. Moreover, this paper presents a fast and robust short-circuit and open-circuit fault detection scheme for power switches and flying capacitors in a hybrid Dickson dc-dc converter. The detection method only observes the low-voltage switching node, which eliminates the challenges associated with high-voltage high-bandwidth sensing. The performance of the design has been verified using a multi-phase 48-V-to-3.3-V 4-to-1 Dickson converter prototype. The measured results demonstrate that the short-circuit faults are detected within two switching cycles of 250 kHz, which is less than the 10-us short-circuit immunity of commercial silicon devices
9 December 2019 in IEEE Transactions on Power Electronics
Emerging autonomous-driving systems necessitate a fault-tolerant power-management system to ensure continuous power delivery to the safety processor and sensor loads, while the forthcoming 48-V bus system requires power conversion at high and wide-ranging input voltages. To address the challenges in future automotive applications, this paper demonstrates a modular multi-phase system with N+1 redundancy as the pre-regulator converter in a two-stage cascaded power-conversion system. Each phase is implemented based on the 4-to-1 hybrid Dickson topology, which enables efficient high-ratio voltage conversion. This paper proposes a new decentralized quasi-fixed-frequency control scheme based on the valley current mode and on-time control. In contrast to existing methods, the proposed scheme 1) enables decentralized interleaving of the multi-phase system using distributed PLL-based synchronization in the event of a failure in any phase, which is advantageous in terms of modularity and scalability, 2) incorporates droop voltage control to achieve balanced current-sharing and voltage regulation in a multi-phase system, and 3) offers self-balancing of the flying-capacitor voltages, which eliminates the need for any additional control circuitry. The performance of the proposed scheme is verified using a 36-W four-phase experimental prototype.