John Pigott

John Pigott

Auto-generated profile, based on publicly available information

John Pigott

Safety & Power Management Department, NXP Semiconductors Inc., Chandler, AZ, USA

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 August 2021 in IEEE Journal of Solid-State Circuits
Verified
Journal Article
Closed access
MAMojtaba Ashourloo
Mojtaba Ashourloo
VNVenkata Raghuram Namburi
Venkata Raghuram Namburi
GPGerard Villar Pique
Gerard Villar Pique
JPJohn Pigott
John Pigott
HBHenk Jan Bergveld
Henk Jan Bergveld
OTOlivier Trescases
Olivier Trescases
Autonomous-driving features necessitate a fault-tolerant (FT) power-management unit in 48-V automotive applications. This article presents a monolithic single-phase closed-loop masterless FT four-to-one hybrid Dickson converter IC for high-conversion-ratio 48-V automotive multi-phase applications. The chip includes: 1) a mixed-signal droop-based valley-current ON-time quasi-fixed-frequency control, which enables masterless multi-phase operation capability; 2) single-point short-circuit fault and open-circuit fault detection and blocking of any power switches or flying capacitors; 3) an optimized high-voltage (HV) power stage with fully integrated flying-capacitor-sourced gate drivers without any external bootstrap capacitors; 4) a glitch-free cross-coupled bootstrapped HV level shifter; and 5) a dual-leg bidirectional closed-loop current-sensing circuit optimized for the hybrid Dickson topology. The design was fabricated in a 0.13- $\mu \text{m}$ 90-V automotive silicon-on-insulator (SOI) bipolar-CMOS–DMOS (BCD) process. The measured results confirm the operation over 20–60-V input, 3.3-V nominal output, 3-A maximum load, and 320-kHz effective switching frequency within the automotive-grade −40 °C–+125 °C ambient temperature. The design achieves above 90% measured efficiency at maximum conversion ratio and load at room temperature. A three-phase system is used to evaluate and confirm the fault-blocking capability and continuous power delivery upon detection of a fault.

8 September 2020 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
MAMojtaba Ashourloo
Mojtaba Ashourloo
VNVenkata Raghuram Namburi
Venkata Raghuram Namburi
GPGerard Villar Pique
Gerard Villar Pique
JPJohn Pigott
John Pigott
HBHenk Jan Bergveld
Henk Jan Bergveld
OTOlivier Trescases
Olivier Trescases
Autonomous-driving features have introduced safety-critical processor modules. A 48-V network has been developed to enable efficient power distribution. A fault-tolerant high-voltage power management unit is required to ensure continuous power delivery to critical loads. This paper compares the cost and efficiency penalty of accommodating the fault-tolerant capability in common dc-dc topologies. The comparison is verified using a 0.13-um high-voltage automotive Bipolar-CMOS-DMOS SMARTMOS technology in a Cadence simulation environment. Besides, a quantitative reliability assessment of the single-phase and multi-phase configurations is presented. This has led to the selection of the hybrid Dickson topology, which has the best electrical performance and comparable cost and reliability among all for high-conversion-ratio fault-tolerant 48-V automotive application. Moreover, this paper presents a fast and robust short-circuit and open-circuit fault detection scheme for power switches and flying capacitors in a hybrid Dickson dc-dc converter. The detection method only observes the low-voltage switching node, which eliminates the challenges associated with high-voltage high-bandwidth sensing. The performance of the design has been verified using a multi-phase 48-V-to-3.3-V 4-to-1 Dickson converter prototype. The measured results demonstrate that the short-circuit faults are detected within two switching cycles of 250 kHz, which is less than the 10-us short-circuit immunity of commercial silicon devices

19 January 2024 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
NKNameer Khan
Nameer Khan
OCOrest Cobani
Orest Cobani
GPGerard Villar Piqué
Gerard Villar Piqué
JPJohn Pigott
John Pigott
HBHenk Jan Bergveld
Henk Jan Bergveld
OTOlivier Trescases
Olivier Trescases
The focus of this work is an auxiliary-assisted 4:1 dual-inductor hybrid (DIH) converter for fast transient response in 48 V PoL applications. The flying capacitor of the DIH converter is utilized as the energy buffer for the auxiliary stage, which is a low-cost, GaN-based bidirectional buck converter. The main DIH converter delivers the dc load power from the 48 V bus using an average-current-mode-control scheme, while the auxiliary stage regulates the output voltage with an output-capacitor-current (OCC) sensing scheme. The proposed architecture operates with a virtual auxiliary voltage bus with minimal auxiliary capacitance, $C_\text{AUX}$ , due to the OCC-sensing scheme. A 40 W prototype has been fabricated to validate the proposed architecture with the virtual bus concept. The prototype achieves a peak efficiency of 93.8% and regulates the output voltage of 1 V within $\pm$ 50 mV during 20 A load transients with an output capacitance of only 800 µF. Experimental results validate the operation of the virtual bus with $C_\text{AUX}$ = 0.47 µF during 20 A load transients while observing a deviation of 4.7 V on the 12 V auxiliary virtual bus voltage, $V_\text{AUX}$ .

9 December 2019 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
MAMojtaba Ashourloo
Mojtaba Ashourloo
VNVenkata Raghuram Namburi
Venkata Raghuram Namburi
GPGerard Villar Pique
Gerard Villar Pique
JPJohn Pigott
John Pigott
HBHenk Jan Bergveld
Henk Jan Bergveld
OTOlivier Trescases
Olivier Trescases
Emerging autonomous-driving systems necessitate a fault-tolerant power-management system to ensure continuous power delivery to the safety processor and sensor loads, while the forthcoming 48-V bus system requires power conversion at high and wide-ranging input voltages. To address the challenges in future automotive applications, this paper demonstrates a modular multi-phase system with N+1 redundancy as the pre-regulator converter in a two-stage cascaded power-conversion system. Each phase is implemented based on the 4-to-1 hybrid Dickson topology, which enables efficient high-ratio voltage conversion. This paper proposes a new decentralized quasi-fixed-frequency control scheme based on the valley current mode and on-time control. In contrast to existing methods, the proposed scheme 1) enables decentralized interleaving of the multi-phase system using distributed PLL-based synchronization in the event of a failure in any phase, which is advantageous in terms of modularity and scalability, 2) incorporates droop voltage control to achieve balanced current-sharing and voltage regulation in a multi-phase system, and 3) offers self-balancing of the flying-capacitor voltages, which eliminates the need for any additional control circuitry. The performance of the proposed scheme is verified using a 36-W four-phase experimental prototype.

16 September 2024 in IEEE Transactions on Circuits and Systems I: Regular Papers
Verified
Journal Article
Closed access
FGFan Guo
Fan Guo
SAShashank Alevoor
Shashank Alevoor
RNRakshit Dambe Nayak
Rakshit Dambe Nayak
JPJohn Pigott
John Pigott
RGRyan Goodfellow
Ryan Goodfellow
BBBertan Bakkaloglu
Bertan Bakkaloglu
Recently, digital ICs with high current slewing characteristics and tight supply voltage margin put increasing demand on the supply regulators. In this paper, an augmented DC-DC buck converter consisting of a lower-frequency main converter and a normally-off fast-switching secondary stage operating in parallel is proposed. The main-stage of the converter uses emulated-current-mode hysteretic control. For the auxiliary transient-suppression stage a nonlinear control scheme termed multiple-single-cycle nonlinear control (MSCNLC) is developed. The proposed augmented regulator improves the load transient response without compromising the overall efficiency of the converter, breaking the well-known efficiency vs. dynamic response trade-off. The high power-efficiency main-stage operating at $F_{sw}=$ 500kHz provides the steady-state DC regulation voltage. The auxiliary-stage adopts a small inductor of 100nH and is only activated when load transient events are detected, providing fast load response, minimizing output voltage deviation. The load transient events are detected through an output capacitor charge tracking circuit, which effectively makes the auxiliary-stage a fast Current-Controlled-Current-Source during transient response. The buck converter is designed for $V_{IN}$ $=$ 3V-5.5V, $V_{OUT}$ $=$ 0.5V-1.1V and $I_{LOAD} =$ 0.5A-8A. It is fabricated in 0.18 $\mu $ m BCD process. The measurement results show that with MSCNLC enabled, the undershoot and overshoot is reduced to 27mV and 58mV during the step-up and step-down response with 2.5A load step by a factor of close to 2, respectively. The recovery time is improved by $\sim$ 1.7x.

22 October 2024 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
NKNameer Khan
Nameer Khan
OCOrest Cobani
Orest Cobani
TRTristan Robitaille
Tristan Robitaille
GPGerard Villar Piqué
Gerard Villar Piqué
JPJohn Pigott
John Pigott
OTOlivier Trescases
Olivier Trescases
This article presents an auxiliary-assisted hybrid dc–dc converter for 48 V automotive voltage regulator modules (VRMs) that enable adaptive inductor-current slew-rate control for ultrafast transient response. The main stage, a 4:1 dual-inductor hybrid (DIH) dc–dc converter, delivers the dc load power, while the output voltage is regulated by a GaN-based auxiliary-buck stage that is accoupled by a buffer capacitor. The main stage regulates the output of the ac-coupled auxiliary stage using an average-current-mode-control (ACMC) scheme to achieve adaptive control of the auxiliary-inductor-current slew rate. The auxiliary ac-coupled buck (ACB) converter regulates the output voltage based on an output-capacitor current-based hysteretic-current-mode-control (HCMC) scheme. An adaptive-voltage-positioning (AVP) scheme is proposed for the auxiliary capacitor, which preemptively positions the ACB output voltage for improved transient response. A small-signal model of the auxiliary-assisted converter is presented for stability analysis and validated with simulation results. A 40 W proof-of-concept prototype was fabricated to demonstrate the feasibility of the adaptive slew-rate control technique and AVP scheme. The prototype achieves a peak efficiency of 90.6% with an output capacitance of 500 μF and an auxiliary capacitance of 22 μF, while maintaining the output voltage deviation within 50 mV.