The joint estimation of the state of charge (SoC) and the parameters of a battery model is typically done using nonlinear extensions of the Kalman filter (KF), such as the well-known and widely used extended KF (EKF), in combination with a simple but relatively accurate equivalent-circuit model. The main limitation of the joint EKF is that extensive tuning of the covariance matrices is required when implementing the observer in an application. This tuning is a tedious task with no clear guidelines for the tuning procedure. Furthermore, the joint EKF and its extensions do not explicitly address model uncertainty and sensor noise, which may be the cause for the problematic tuning. In this article, we combine a nonlinear observer with the structured representation of model uncertainty and disturbances as typically used in a robust-observer design approach. Therefore, the joint EKF for simultaneous estimation of SoC and model parameters will be presented for the case that includes cross-correlated noises. Moreover, inspired by the conditions for enforcing convergence of the SoC estimation error, a so-called forgetting factor will be introduced to the joint EKF. These adaptations lead to an observer with a single tuning parameter. The experimental results show that tuning of the proposed observer is straightforward and the performance is similar to a regular joint EKF with a root-mean-square SoC error of 0.5%.
The range of electric vehicles (EV), especially those powered by aged battery packs, is partly limited by cell-to-cell imbalance, i.e., the weakest cell determines the performance of the entire battery pack. Active cell balancing can mitigate these differences, but balancing ad hoc discrepancies in voltage or state-of-charge (SoC) does not necessarily result in the best performance in terms of range. This brief employs a distributed feasibility approach to retrieve the maximum range and corresponding balancing currents for a specific scenario. Moreover, using aging data from literature and a real-time applicable model-predictive-controller, a lifetime projection is made on the benefits of active cell balancing, which shows that a significant extension of End-of-Life (EoL) is achieved, i.e., 10% for the considered example. Finally, we show when and why the applied balancing controller, which can effectively balance a battery pack using balancing currents with a maximum C-rate of only 1/50C, performs better than others in terms of maximizing the range.
In order to meet the required power and energy demand of battery‐powered applications, battery packs are constructed from a multitude of battery cells. For safety and control purposes, an accurate estimate of the temperature of each battery cell is of vital importance. Using electrochemical impedance spectroscopy (EIS), the battery temperature can be inferred from the impedance. However, performing EIS measurements simultaneously at the same frequency on each cell in a battery pack introduces crosstalk interference in surrounding cells, which may cause EIS measurements in battery packs to be inaccurate. Also, currents flowing through the pack interfere with impedance measurements on the cell level. In this paper, we propose, analyse, and validate a method for estimating the battery temperature in a battery pack in the presence of these disturbances. First, we extend an existing and effective estimation framework for impedance‐based temperature estimation towards estimating the temperature of each cell in a pack in the presence of crosstalk and (dis)charge currents. Second, the proposed method is analysed and validated on a two‐cell battery pack, which is the first step towards development of this method for a full‐size battery pack. Monte Carlo simulations are used to find suitable measurement settings that yield small estimation errors and it is demonstrated experimentally that, over a range of temperatures, the method yields an accuracy of ±1°C in terms of bias, in the presence of both disturbances.
25 August 2021 in IEEE Journal of Solid-State Circuits
Autonomous-driving features necessitate a fault-tolerant (FT) power-management unit in 48-V automotive applications. This article presents a monolithic single-phase closed-loop masterless FT four-to-one hybrid Dickson converter IC for high-conversion-ratio 48-V automotive multi-phase applications. The chip includes: 1) a mixed-signal droop-based valley-current ON-time quasi-fixed-frequency control, which enables masterless multi-phase operation capability; 2) single-point short-circuit fault and open-circuit fault detection and blocking of any power switches or flying capacitors; 3) an optimized high-voltage (HV) power stage with fully integrated flying-capacitor-sourced gate drivers without any external bootstrap capacitors; 4) a glitch-free cross-coupled bootstrapped HV level shifter; and 5) a dual-leg bidirectional closed-loop current-sensing circuit optimized for the hybrid Dickson topology. The design was fabricated in a 0.13- $\mu \text{m}$ 90-V automotive silicon-on-insulator (SOI) bipolar-CMOS–DMOS (BCD) process. The measured results confirm the operation over 20–60-V input, 3.3-V nominal output, 3-A maximum load, and 320-kHz effective switching frequency within the automotive-grade −40 °C–+125 °C ambient temperature. The design achieves above 90% measured efficiency at maximum conversion ratio and load at room temperature. A three-phase system is used to evaluate and confirm the fault-blocking capability and continuous power delivery upon detection of a fault.