Fang Chen

Fang Chen

Auto-generated profile, based on publicly available information

Fang Chen

State Grid Shanghai Electric Power Companys electric power research institute,Shanghai,China

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 January 2019 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
FCFang Chen
Fang Chen
RBRolando Burgos
Rolando Burgos
DBDushan Boroyevich
Dushan Boroyevich
Juan C. VasquezJuan C. Vasquez
Juan C. Vasquez
Josep M. GuerreroJosep M. Guerrero
Josep M. Guerrero
Linear droop faces the design tradeoff between voltage regulation and load sharing due to cable resistances and sensing errors. Using a larger droop resistance improves load sharing, but requires a wider droop voltage range. In the nonlinear droop, droop resistance is a function of the converter's output current, and its value increases when the output current increases. As a result, the impacts from sensors and cables are reduced. In this paper, the design of nonlinear droop in dc power distribution systems is studied with special emphasis on load sharing, voltage regulation, system efficiency, and stability. After discussing the piecewise linear and nonlinear droop control, a generic polynomial expression is presented to unify different droop equations. The impact of droop on dc system efficiency is analyzed by evaluating cable and power converter losses. The converter's output impedance using nonlinear droop is modeled to analyze the system stability with constant power loads. The selection and design guidelines of nonlinear droop are summarized, considering both the static performance and interaction with load systems. The analysis is verified in 400-V multi-source dc systems. The nonlinear droop is fully distributed as it only needs local information.

1 December 2016 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
CLChendan Li
Chendan Li
FBFederico de Bosio
Federico de Bosio
FCFang Chen
Fang Chen
Sanjay Kumar ChaudharySanjay Kumar Chaudhary
Sanjay Kumar Chaudhary
Juan C. VasquezJuan C. Vasquez
Juan C. Vasquez
Josep M. GuerreroJosep M. Guerrero
Josep M. Guerrero
In this paper, an economic dispatch problem for total operation cost minimization in dc microgrids is formulated. An operating cost is associated with each generator in the microgrid, including the utility grid, combining the cost-efficiency of the system with demand response requirements of the utility. The power flow model is included in the optimization problem, thus the transmission losses can be considered for generation dispatch. By considering the primary (local) control of the grid-forming converters of a microgrid, optimal parameters can be directly applied to this control level, thus achieving higher control accuracy and faster response. The optimization problem is solved in a heuristic method. In order to test the proposed algorithm, a six-bus droop-controlled dc microgrid is used in the case studies. Simulation results show that under variable renewable energy generation, load consumption, and electricity prices, the proposed method can successfully reduce the operating cost by dispatching economically the resources in the microgrid.

31 May 2017 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
XYXiaolong Yue
Xiaolong Yue
DBDushan Boroyevich
Dushan Boroyevich
FLFred C. Lee
Fred C. Lee
FCFang Chen
Fang Chen
RBRolando Burgos
Rolando Burgos
FZFang Zhuo
Fang Zhuo
The interaction of power electronic converters in a microgrid can introduce system instability and power quality issues. Existing investigations focus on interactions either in low-frequency regions, such as the constant power load, or in very high-frequency regions like electromagnetic interference. However, interactions of power converters around their switching frequency range are not included. In fact, the interaction of dc-dc converters with different switching frequencies can introduce beat frequency oscillation in certain cases. Since additional frequency component (beat frequency) is generated, traditional impedance concept is no longer the tool for beat frequency oscillation analysis and new models need to be developed. In this paper, a crossed frequency output impedance matrix model is proposed to describe the terminal characteristics of a dc-dc converter around its switching frequency range. A high-frequency equivalent circuit model for the converter is then developed to predict the beat frequency oscillation in parallel and cascaded systems, which results from the interaction of power converters with different switching frequencies. Finally, design guidelines are proposed to avoid potential beat frequency oscillation in a dc nanogrid. Experimental results for both parallel and cascaded systems validate the accuracy and effectiveness of the proposed prediction method and design guidelines.

27 April 2018 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
FCFang Chen
Fang Chen
RBRolando Burgos
Rolando Burgos
DBDushan Boroyevich
Dushan Boroyevich
This paper presents an interface ac-dc converter to connect the 380 V bipolar dc microgrid with the 240 V split-phase single-phase ac utility. The design targets are high efficiency, small volume and symmetric bipolar dc bus generation. A transformerless two-stage topology is proposed to decouple the low-frequency common-mode (CM) voltage between the connected ac and dc systems. The two-stage structure also reduces the required capacitance in single-phase power conversion by allowing voltage ripple on the intermediate dc-link. Adaptive dc-link voltage control and interleaving of state-of-the-art silicon carbide (SiC) MOSFETs are adopted to achieve high efficiency. Interleaving angles are optimized for a small volume of both differential-mode and CM magnetics. An active CM control method is incorporated to regulate the dc and low-frequency CM voltages on the dc buses. The resultant dc bus voltages are rendered symmetric to the ground, and the leakage current is suppressed. The generated - 190 V dc bus is suitable for bipolar 380 V dc power distribution systems. Pluggable phase-leg modules with embedded driving and protection circuit are designed and tested, based on which a 10 kW converter prototype is built achieving an efficiency > 97 %.

1 May 2018
Verified
Conference Paper
Closed access
JZJingyi Zhang
Jingyi Zhang
CLChao Lu
Chao Lu
CFChen Fang
Chen Fang
XLXiang Ling
Xiang Ling
YZYong Zhang
Yong Zhang
In this paper, a novel load shedding scheme against voltage instability with deep reinforcement learning (DRL). The convolutional neural networks (CNNs) are chosen to automatically learn the features and exploit the local spatial correlations from TS data of voltages. The DRL load shedding controller interacts with system dynamics through a sequence of observations, actions and rewards with two convolutional neural networks, namely critic and actor networks. The critic network is used to evaluate the quality of the load shedding actions and the actor network to determine the time, location and amounts of load shedding (LS). A global reward function is defined considering the recovery characteristics of voltages and total load shedding amounts to guarantee the coordination of under voltage load shedding (UVLS). The simulation is performed on the modified New England 39-bus system, and the results validate the voltage recovery performance and load shedding amount of the proposed scheme under different scenario.

21 November 2016
Verified
Conference Paper
Closed access
FCFang Chen
Fang Chen
RBRolando Burgos
Rolando Burgos
DBDushan Boroyevich
Dushan Boroyevich
EREnrique Rodriguez-Diaz
Enrique Rodriguez-Diaz
LMLexuan Meng
Lexuan Meng
Josep M. GuerreroJosep M. Guerrero
Josep M. Guerrero
DC Microgrid attains popularity in integrating renewable energy sources and batteries. It also has the potential to achieve higher efficiency than ac power grid with optimized power flow. In this paper, a general dc microgrid is modeled based on a cluster of general dc nodes, which includes constant power renewables generation, droop-controlled voltage source and different kinds of load. Then the dc power flow is solved for optimization. A voltage restoration method based on consensus algorithm is used to restore the voltage deviation from droop characteristic. An enhanced current regulator is adopted to guarantee the accurate load sharing even under the influence of sensor drift and line resistance. A tie line power flow control method is proposed to regulate the tie line power directly and increase the system efficiency at light load condition. All the considered methods only need the local information and the information from its nearest neighbor thus the system expendability is guaranteed. Simulation and experiment results are provided to validate the proposed methods.