Inexpensive, nonintrusive, and easy-installation current sensors are of great help in the economical and reliable operation of power systems. In this article, a novel contactless current sensor with small size, ultramicro power consumption, and self-power capability is proposed based on tunnel magnetoresistance (TMR). For measuring arbitrary line currents under an interference magnetic field, the single-axis TMR chips array and anti-interference method are introduced. Then, the designs of software and hardware are given for ultralow-power consumption and self-power. The experimental results showed that the measuring range of the current sensor is from 0 to 1500 A, and the error is less than 0.6% when the measured current is over 150 A.
Multi-functional magnetic sensors with tunable measure range can help cover different requirements from detecting weak field to sensing strong field. However, additional control system is often required to realize the tunability, which increases the complexity of device. In this work, we found the current controlled sensitivity and linear range in the NiCo2O4 thin film based anomalous hall sensor. The device owns not only simple structure but also interesting anomalous hall signal whose linearity range and sensitivity can be controlled by current. Ultrahigh sensitivity of 4900 V/(AT) in the range of ±0.2 mT and competitive sensitivity of 20 V/(AT) in the range of ±23 mT are simultaneously realized by tunning the work current. In addition, a memory switching characteristic controlled by magnetic field is further found in the device. These results show that the anomalous hall device has the potential for multifunctional compact device.
As wind power generation technology rapidly advances, the threat of wind turbine failures to the secure and stable operation of the power grid is gaining increasing attention. Real-time monitoring of operation status and predicting potential failures in wind turbines are indispensable requirements for the safe integration of wind power. In this paper, a model based on the least squares support vector machine (LSSVM), whose parameters are optimized by the Big Bang–Big Crunch algorithm, is constructed to improve the monitoring of wind turbine operation status and fault prediction accuracy. The research methodology consists of several key stages. Firstly, the initial wind turbine sensing data are preprocessed, utilizing factor analysis to reduce dimensionality and obtain the main influencing factors of wind turbine operation. Then, an improved failure prediction model for wind turbines, based on the least squares support vector machine, is developed using the preprocessed data. The model parameters are optimized by utilizing the Big Bang–Big Crunch optimization algorithm to enhance the prediction accuracy of wind turbine failures. Finally, the feasibility and accuracy of the proposed method are validated through a case study conducted on a regional power grid with wind farm integration.
This paper proposes a fault location method for power cables based on distributed fiber optic vibration sensing technology to monitor the damage caused by power cable discharge to the surrounding fiber-optic cables. When the power cable discharge to the ground does not cause damage to the surrounding fiber optic cable, the proposed technology can accurately locate the longitudinal distance between the vibration source and the fiber optic cable, based on distributed fiber optic vibration sensing and positioning technology. When the power cable discharge causes the breakage of the fiber optic cable in the same trench, the proposed technology could achieve the precise fault location of the power cable, based on the lead ball free fall control system. The advantages and disadvantages of the proposed technique and its application scenarios are analyzed through field tests to provide a reference for future cable fault location research.
20 October 2026 in Sensors and Actuators A: Physical