Inexpensive, nonintrusive, and easy-installation current sensors are of great help in the economical and reliable operation of power systems. In this article, a novel contactless current sensor with small size, ultramicro power consumption, and self-power capability is proposed based on tunnel magnetoresistance (TMR). For measuring arbitrary line currents under an interference magnetic field, the single-axis TMR chips array and anti-interference method are introduced. Then, the designs of software and hardware are given for ultralow-power consumption and self-power. The experimental results showed that the measuring range of the current sensor is from 0 to 1500 A, and the error is less than 0.6% when the measured current is over 150 A.
12 April 2024 in IEEE Transactions on Power Electronics
The low power density of a magnetic field energy harvester (MFEH) limits its applicability. Conventional methods for improving power harvesting, e.g., increasing the volume of the magnetic core, cannot effectively increase the output power density of the MFEH and it increases the burden on the transmission lines. An in-depth investigation reveals that by adding an optimal series-connected capacitor before the rectifier, the output power of the MFEH can be maximized. By reducing the net voltage applied to the magnetizing inductance, the flux accumulation is slower, lengthening the energy harvesting time, and the output power is increased. Furthermore, the output power can be maximized with an optimal series-connected capacitor. The design method of the optimal series-connected capacitor is theoretically analyzed in this article, which is only related to the load characteristics. In addition, the proposed method has a simple structure and can effectively improve the system power density of the MFEH. An experimental prototype is constructed to verify the effectiveness of the proposed method, and the results agree well with the theoretical analysis. Compared with the conventional MFEH without a series-connected capacitor, the method presented in this article can increase the harvested power by approximately 50%.
As wind power generation technology rapidly advances, the threat of wind turbine failures to the secure and stable operation of the power grid is gaining increasing attention. Real-time monitoring of operation status and predicting potential failures in wind turbines are indispensable requirements for the safe integration of wind power. In this paper, a model based on the least squares support vector machine (LSSVM), whose parameters are optimized by the Big Bang–Big Crunch algorithm, is constructed to improve the monitoring of wind turbine operation status and fault prediction accuracy. The research methodology consists of several key stages. Firstly, the initial wind turbine sensing data are preprocessed, utilizing factor analysis to reduce dimensionality and obtain the main influencing factors of wind turbine operation. Then, an improved failure prediction model for wind turbines, based on the least squares support vector machine, is developed using the preprocessed data. The model parameters are optimized by utilizing the Big Bang–Big Crunch optimization algorithm to enhance the prediction accuracy of wind turbine failures. Finally, the feasibility and accuracy of the proposed method are validated through a case study conducted on a regional power grid with wind farm integration.
This paper proposes a fault location method for power cables based on distributed fiber optic vibration sensing technology to monitor the damage caused by power cable discharge to the surrounding fiber-optic cables. When the power cable discharge to the ground does not cause damage to the surrounding fiber optic cable, the proposed technology can accurately locate the longitudinal distance between the vibration source and the fiber optic cable, based on distributed fiber optic vibration sensing and positioning technology. When the power cable discharge causes the breakage of the fiber optic cable in the same trench, the proposed technology could achieve the precise fault location of the power cable, based on the lead ball free fall control system. The advantages and disadvantages of the proposed technique and its application scenarios are analyzed through field tests to provide a reference for future cable fault location research.
Based on the capacitor voltage divider method, a miniature smart voltage sensing method is proposed, which employs a scheme that dynamically measures the coupling capacitor between the voltage sensor and the ground. Then a prototype of miniature smart voltage sensor (MSVS) is developed. The Performance of the proposed method is evaluated through theoretical analysis and experimental tests. The experimental tests show that the MSVS has high precision, good linearity and certain high-frequency signal acquisition capability.