Christoph Weichert

Christoph Weichert

Auto-generated profile, based on publicly available information

Christoph Weichert

Physikalisch-Technische Bundesanstalt Braunschweig und Berlin, Bundesallee 100, 38116, Braunschweig, Germany

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 May 2020 in Measurement Science and Technology
Verified
Journal Article
Closed access
PDF file
Liang YuLiang Yu
Liang Yu
GMGabor Molnar
Gabor Molnar
CWChristian Andreas Werner
Christian Andreas Werner
CWChristoph Weichert
Christoph Weichert
RKRainer Koening
Rainer Koening
JFJens Fluegge
Jens Fluegge
In this paper, a camera-based 3DoF homodyne interferometer is proposed to measure displacements and rotations with precision below nanometre/microradian level. The interferometer uses a single beam, has a simple and compact layout and is easy to adjust. A spatial interference pattern is introduced by a tilted reference mirror and recorded by a camera chip. The variation of the spacing and orientation of the fringes is correlated with the yaw and pitch angular rotation of the moving mirror, while the phase correlates with its displacement. The noise level and resolution of displacement and angle measurements were determined to be below 5 pm/√Hz and 5 nrad/√Hz above 1 Hz. Periodic nonlinearities of the system were mainly caused by multi-reflections between optical surfaces in the system. By choosing particular components and improving their adjustment, the displacement nonlinearity was reduced to be below 0.1 nm, and angle nonlinearities achieved sub-microradian level.

25 July 2012 in Measurement Science and Technology
Verified
Journal Article
Closed access
RKRainer Köning
Rainer Köning
CWChristoph Weichert
Christoph Weichert
BPBernd Przebierala
Bernd Przebierala
JFJens Flügge
Jens Flügge
WHWolfgang Haessler-Grohne
Wolfgang Haessler-Grohne
HBHarald Bosse
Harald Bosse

17 April 2018 in Measurement Science and Technology
Verified
Journal Article
Closed access
PDF file
CWChristoph Weichert
Christoph Weichert
PKPaul Köchert
Paul Köchert
ESEugen Schötka
Eugen Schötka
JFJens Fluegge
Jens Fluegge
EMEberhard Manske
Eberhard Manske
The uncertainty of a straightness interferometer is independent of the component used to introduce the divergence angle between the two probing beams, and is limited by three main error sources, which are linked to each other: their resolution, the influence of refractive index gradients and the topography of the straightness reflector. To identify the configuration with minimal uncertainties under laboratory conditions, a fully fibre-coupled heterodyne interferometer was successively equipped with three different wedge prisms, resulting in three different divergence angles (4°, 8° and 20°). To separate the error sources an independent reference with a smaller reproducibility is needed. Therefore, the straightness measurement capability of the Nanometer Comparator, based on a multisensor error separation method, was improved to provide measurements with a reproducibility of 0.2 nm. The comparison results revealed that the influence of the refractive index gradients of air did not increase with interspaces between the probing beams of more than 11.3 mm. Therefore, over a movement range of 220 mm, the lowest uncertainty was achieved with the largest divergence angle. The dominant uncertainty contribution arose from the mirror topography, which was additionally determined with a Fizeau interferometer. The measured topography agreed within ±1.3 nm with the systematic deviations revealed in the straightness comparison, resulting in an uncertainty contribution of 2.6 nm for the straightness interferometer.

7 July 2015 in TM - Technisches Messen
Verified
Journal Article
Closed access
HBHarald Bosse
Harald Bosse
BBBernd Bodermann
Bernd Bodermann
GDGaoliang Dai
Gaoliang Dai
JFJens Flügge
Jens Flügge
CFCarl G. Frase
Carl G. Frase
CWChristoph Weichert
Christoph Weichert
Recent developments of the PTB in high precision position and size metrology as support for different nanotechnology applications are described. Measurement uncertainties of 1–2 nm for 1D-position of graduation lines on photomasks, or on line scales and incremental encoders of about 300 mm length have been achieved. The measurement of the size of nanoscale features represents additional challenges, because the location of opposite feature edges needs to be precisely determined. Different feature size or CD metrology techniques are applied at PTB, including a recent approach which uses transmission electron microscopy in the traceability chain of AFM CD measurements. The estimated uncertainty for CD measurements on high quality Si line structures is U 95% = 1.6 nm.

23 November 2009
Verified
Book Chapter
Closed access
PDF file
CWCh. Weichert
Ch. Weichert
JFJ. Flügge
J. Flügge
RKR. Köning
R. Köning
HBH. Bosse
H. Bosse
RTR. Tutsch
R. Tutsch

20 September 2017 in TM - Technisches Messen
Verified
Journal Article
Closed access
PDF file
PKPaul Köchert
Paul Köchert
EMEberhard Manske
Eberhard Manske
RKRainer Köning
Rainer Köning
CWChristoph Weichert
Christoph Weichert
JFJens Flügge
Jens Flügge
Zusammenfassung In diesem Beitrag wird ein neues Antriebskonzept des an der PTB für Längenmessungen bis zu 0,55 m betriebenen Vakuumkomparators beschrieben. Dessen Positioniersystem auf Basis eines Direktantriebs wurde um eine sekundäre Steuereinheit erweitert, um auf Grundlage von Rückkopplungsdaten seines Vakuum-Interferometers einen zusätzlichen elektromagnetischen Aktuator anzutreiben. Anhand von Messungen konnte mit diesem dezentralen Antriebskonzept ein Positionsrauschen (1 σ) von 0,2 nm bei einer Mitteilungszeit von 10 ms nachgewiesen werden.