Fabian Buchfellner

Fabian Buchfellner

Auto-generated profile, based on publicly available information

Fabian Buchfellner

Photonics Lab of Munich University of Applied Sciences, Munich, Germany

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 December 2022 in Optics Letters
Verified
Journal Article
Closed access
FBFabian Buchfellner
Fabian Buchfellner
QBQiang Bian
Qiang Bian
JFJinghua Fu
Jinghua Fu
XHXiangyang Hu
Xiangyang Hu
MYMinghong Yang
Minghong Yang
JRJohannes Roths
Johannes Roths
A novel, to the best of our knowledge, sensor architecture for palladium-coated fiber Bragg gratings is proposed and demonstrated that allows highly accurate multi-parameter sensing and decoupling of hydrogen concentration from temperature. By means of partly Pd-coated Pi-shifted FBGs (PSFBGs), the notch wavelength of the narrow transmission band and the flank wavelength of the broader reflection band experience different hydrogen and temperature sensitivities. PSFBGs were calibrated at hydrogen concentrations between 800 and 10,000 ppm and temperatures from 20 to 40°C, and a decreased hydrogen sensitivity at increased temperatures was found. Nonlinear temperature-dependent hydrogen calibration functions were therefore determined. An iterative matrix algorithm was used to decouple hydrogen concentration and temperature and to account for the nonlinear calibration functions. Achieved improvements and results have great importance for real field applications of FBG-based hydrogen sensing.

14 November 2022 in IEEE Sensors Journal
Verified
Journal Article
Closed access
XHXiangyang Hu
Xiangyang Hu
JFJinghua Fu
Jinghua Fu
JDJixiang Dai
Jixiang Dai
HYHongrui Ye
Hongrui Ye
FZFan Zhang
Fan Zhang
JRJohannes Roths
Johannes Roths
Pd-based alloy coating on optical fiber is widely employed for hydrogen concentration sensing. However, it is difficult to distinguish the Pd-based alloy expansion from hydrogen-adsorption or thermal-effect. In this paper, a novel fiber-optic hydrogen sensor based on π-shifted FBG with locally coated Pd/Ta alloy layer, which enables an in-situ temperature compensation, is proposed and experimentally demonstrated. The hydrogen sensitivity difference between the extremely narrow peak of π-shifted FBG and the sidelobe wavelength are employed to realize the hydrogen concentration detection with temperature compensation. Theoretical simulation and experiment show that the hydrogen sensitivity of the structure can be enhanced by optimizing the partially-coating length. When the alloy length is 2 mm for a 10 mm-grating, the wavelength shifts of central and sidelobe 19.2 pm and 6.0 pm are achieved respectively at 1% hydrogen concentration. Maximum hydrogen sensitivity after temperature compensation of 13.2 pm is obtained. The proposed local-compensated method based on partially-coating on π-shifted FBG is particularly potential for oxygen-free environments with high requirement on hydrogen accuracy.

2 February 2023 in Journal of Lightwave Technology
Verified
Journal Article
Closed access
QBQiang Bian
Qiang Bian
FDFranz Dutz
Franz Dutz
MLMarkus Lindner
Markus Lindner
FBFabian Buchfellner
Fabian Buchfellner
ASAndrea Stadler
Andrea Stadler
JRJohannes Roths
Johannes Roths
Regenerated fiber Bragg gratings (RFBGs) have been created in large mode area (LMA) fibers, and their key properties for their application as high-temperature sensors were experimentally characterized. UV written Type-I seed gratings in standard single-mode fibers (SMF-28) and in low numerical aperture LMA fibers with 125 μm and 250 μm cladding diameters were regenerated, and their wavelength drift characteristics at high temperatures, their temperature sensitivities, and their mechanical strengths were tested and compared with each other. We found that low dopant concentrations in the fiber cores led to lower wavelength drift rates during and after regeneration. A temperature calibration from room temperature to 800 $^\circ$ C showed that LMA fibers have generally similar but slightly lower temperature sensitivities than SMF-28 fibers. The tensile strength tests showed that LMA fibers with 250 μm cladding diameter have similar tensile fracture stresses as SMF-28 fibers but four times larger tensile force tolerances because of their twofold fiber diameter. Our research shows that using LMA fibers for RFBGs offers significant advantages for high-temperature sensing than their counterparts in standard fibers, which are also applicable to other silica fiber-based high-temperature sensors.

6 December 2024 in Optics Express
Verified
Journal Article
Closed access
FBFabian Buchfellner
Fabian Buchfellner
ARAlexander Roehrl
Alexander Roehrl
MYMinghong Yang
Minghong Yang
AKAlexander W. Koch
Alexander W. Koch
JRJohannes Roths
Johannes Roths
This study presents an in-situ temperature-decoupled sensor platform utilizing an in-fiber Fabry-Perot (FP) etalon made of two fiber Bragg gratings (FBGs) for simultaneous hydrogen concentration and temperature sensing. The platform’s key feature is a palladium-alloy-coated fiber section between the FBGs, while the FBGs themselves remain without coating. This design shifts the FP transmission fringes due to hydrogen-induced strain and temperature. In contrast, the envelope function induced by the FBG spectra shifts only with temperature, enabling intra-spectral referencing of the fringe wavelength to the envelope vertex wavelength and thereby compensating for temperature effects. This work discusses a fully zero-point-referenced sensor calibration for simultaneous hydrogen and temperature monitoring. Hydrogen calibration demonstrated precise measurement of concentrations ranging from 500 to 20,000 ppm(H2) in a temperature range of 20∘C to 50∘C. Utilizing an iterative matrix algorithm, the non-linear hydrogen response was linearized and temperature cross-sensitivity was almost completely decoupled, leading to the representation of hydrogen concentrations with standard errors of the mean of 4.3% at repeated 1,000 ppm cycles, 2.8% at repeated 10,000 ppm cycles, and temperature measurement uncertainties of ±0.2∘C. This proof-of-concept demonstrates the detection of low hydrogen quantities without distraction from temperature and thereby opens the path for fiber optic hydrogen sensing applications outside laboratories.

19 November 2022 in Journal of Alloys and Compounds
Verified
Journal Article
Closed access
QBQiang Bian
Qiang Bian
CBConstantin Bauer
Constantin Bauer
ASAndrea Stadler
Andrea Stadler
FBFabian Buchfellner
Fabian Buchfellner
MJMartin Jakobi
Martin Jakobi
JRJohannes Roths
Johannes Roths

23 November 2022 in Optics Express
Verified
Journal Article
Closed access
FBFabian Buchfellner
Fabian Buchfellner
ASAndrea Stadler
Andrea Stadler
QBQiang Bian
Qiang Bian
MHMaximilian Hennesen
Maximilian Hennesen
AZAndreas Zeisberger
Andreas Zeisberger
JRJohannes Roths
Johannes Roths
A new calibration methodology for regenerated fiber Bragg grating (RFBG) temperature sensors up to 700 °C is proposed and demonstrated. A generalized, wavelength-dependent temperature calibration function is experimentally determined that describes the temperature-induced wavelength shifts for all RFBG sensor elements that are manufactured with the same fabrication parameters in the wavelength range from 1465 nm to 1605 nm. Using this generalized calibration function for absolute temperature measurements, each RFBG sensor element only needs to be calibrated at one reference temperature, representing a considerable simplification of the conventional calibration procedure. The new calibration methodology was validated with 7 RFBGs, and uncertainties were found to be compliant with those of Class 1 thermocouples (< ±1.5 K or < ±0.4% of the measured temperature). The proposed calibration technique overcomes difficulties with the calibration of spatially extended multipoint RFBG sensor arrays, where setting up an adequate calibration facility for large sensor fibers is challenging and costly. We assume that this calibration method can also be adapted to other types of FBG temperature sensors besides RFBGs. An accurate and practical calibration approach is essential for the acceptance and dissemination of the fiber-optic multipoint temperature sensing technology.