View All Publications
30 June 2022 in Ophthalmology in Russia
Verified
Journal Article
Open access
PDF file
BAB. M. Aznabaev
B. M. Aznabaev
TDT. I. Dibaev
T. I. Dibaev
RMR. G. Mukhametov
R. G. Mukhametov
TMT. R. Mukhamadeev
T. R. Mukhamadeev
GIG. M. Idrisova
G. M. Idrisova
TIT. N. Ismagilov
T. N. Ismagilov
The balance between the efficiency of lens’ destruction and the safety of this process for intraocular structures is the most important aspect in the search for alternative energy approaches in cataract surgery. The article provides a literature review summarizing modern medical and technical solutions aimed at developing new and effective methods of cataract phacoemulsification. One of the main components of cataract surgery is the balance between the effectiveness of ultrasound destruction of the lens and the safety of this process for intraocular structures. Most of the available technical solutions designed to replace ultrasound do not yet allow this to be fully implemented, since they have insufficient destructive power or are technologically complex and expensive, which makes it difficult for their mass introduction into widespread practice. In this regard, it is urgent to search for alternative energy approaches aimed at increasing the efficiency of destruction without increasing the negative effects associated with an increase in ultrasound dose.

29 June 2026 in Russian Annals of Ophthalmology
Verified
Journal Article
Closed access
TDT.I. Dibaev
T.I. Dibaev
BAB.M. Aznabaev
B.M. Aznabaev
LMLyalya Musina
Lyalya Musina
TMT.R. Mukhamadeev
T.R. Mukhamadeev
AVA.S. Vafiev
A.S. Vafiev
Current trends in the development of vitrectomy systems, particularly vitreous cutters, focus on reducing instrument gauge while maintaining high cutting efficiency and vitreous fragmentation capacity. Pneumatic guillotine vitreous cutters have several design limitations that constrain further improvement of their functional capabilities. The use of ultrasonic energy for vitreous fragmentation represents an alternative direction in the development of vitrectomy. The emergence of microinvasive ultrasonic 25-gauge (25G) vitreous cutters creates the need for a comprehensive assessment of their effect on ultrastructure of the retina. Objective. The study investigated ultrastructural changes in the retina of rabbits after experimental microinvasive ultrasonic and pneumatic guillotine 25G vitrectomy. Material and methods. Rabbits in the main study group underwent microinvasive ultrasonic and pneumatic guillotine 25G vitrectomy. The retina was examined using electron microscopy. The data obtained in the experimental group, in which microinvasive ultrasonic vitrectomy was used, were then compared with the results of the control group, in which 25G pneumatic guillotine vitrectomy was performed. Results. On days 1 and 7, signs of retinal changes were detected in the inner nuclear layer and nerve fiber layer: vacuolization and fragmentation of neuronal cytoplasm, vacuolization of mitochondria, and elements of the rough endoplasmic reticulum. On days 14 and 30, some structural changes persisted — although the severity of the changes decreased. The nature of the changes in the experimental group was comparable with that in the control group and could be attributed not only to the identical effect of fragmentation, but also to nonspecific surgical trauma, hydrodynamic effects of fluid flow, changes associated with preparation of the material for electron microscopic examination, and individual tissue responses. Conclusion. The ultrastructural changes in the experimental group were similar in nature and severity to those observed in the control group. Therefore, microinvasive ultrasonic 25G vitrectomy can be considered a safe technology for vitreous fragmentation, with an effect on the retinal ultrastructure comparable to that of the traditional guillotine fragmentation method.

16 October 2023 in International Journal of Veterinary Medicine
Verified
Journal Article
Open access
PDF file
AVA. S. Vafiev
A. S. Vafiev
SKS. Y. Kontsevaya
S. Y. Kontsevaya
BAB. M. Aznabaev
B. M. Aznabaev
LMLyalya Musina
Lyalya Musina
APAlexey Prusakov
Alexey Prusakov
СКС. Ю. Концевая
С. Ю. Концевая
Currently, three groups of scientists are developing the introduction and use of lowfrequency ultrasound in retinal and vitreous surgery. There is not enough data and work to study the effects of this type of energy on the functional activity and structural state of the retina. In this regard, we conducted experimental and diagnostic studies using modern and objective methods. The main purpose of this article is analyzing the parameters of the electroretinogram of the rabbit retina and compare it with histological data after removal of the vitreous body using low-frequency ultrasound and mechanical action. Experiments were conducted on Chinchilla rabbits (n=40). In the experimental group (n=20), vitreous removal was performed using low-frequency ultrasound, in the control group (n=20) using a guillotine mechanism. On the 1st, 7th, 14th and 14th days, the parameters of the a- and b-waves of the electroretinogram were recorded. The structural state of the retina was also evaluated on histological sections. On the 1st day after surgery in both study groups there was a decrease in all parameters of the electroretinogram, the evaluation of histological data showed the presence of edema in most layers of the retina. On days 7 and 14, the parameters of the a- and b-waves were restored, but did not return to normal in both groups, a decrease in edema in all layers of the retina was observed on histological preparations. On day 30, the a- and b-wave indicators returned to normal, which indicates the restoration of the functional properties of photoreceptor cells, bipolar and Muller cells in both groups, the retinal layers were clearly visualized on histological sections without signs of edema. Analysis of electroretinogram parameters and histological data showed that the use of low-frequency ultrasound for vitreous removal can be considered safe and promising for further development.

21 March 2022 in RUDN Journal of Medicine
Verified
Journal Article
Open access
PDF file
AVAleksander S. Vafiev
Aleksander S. Vafiev
ВСВафиев А. С.
Вафиев А. С.
Relevance. Currently, several groups of scientists are working on the implementation of low-frequency ultrasound in surgery of the retina and vitreous body. But there are not enough articles on the study of the functional activity of the retina when exposed to this type of energy. Electrophysiological research methods make it possible to analyze and evaluate the safety, effectiveness of surgical interventions, the effect of new drugs at the level of neurons and visual pathways. The electroretinography method makes it possible to record the bioelectrical activity of retinal neurons during light stimulation during dark and light adaptation. The aim of the study is to carry out a comparative analysis of the aand b-wave indices of the rabbit electroretinogram after experimental removal of the vitreous body using low-frequency ultrasound and mechanical action. Materials and Methods. Experiments were carried out in two groups of Chinchilla rabbits (n = 40). In the experimental group, surgery to remove the vitreous body was performed using low-frequency ultrasound, in the control group a fragmentator with guillotine mechanism was used. Before and after the surgery (1, 7, 14, 30 days) an electroretinogram was recorded, the parameters of the amplitude and latency of the aand b-waves were measured. Results and Discussion. In both groups, a sharp decrease in all parameters was observed on day 1. Later, on the 7th day, the dynamics of the latency of aand b-waves slightly decreased than the preoperative values. On the 14th day after the exposure, the amplitude and peak latency of the aand bwaves in both groups remained at the same level as on the 7th day. On the 30th day, the indicators increased, which indicates the restoration of the functions of photoreceptors and Mueller cells in both groups. There were no statistically significant differences between the study groups at all periods of the study. Conclusion. The use of low-frequency ultrasound for vitreous removal can be considered safe and has prospects for further development and application.

1 January 2023 in Современные проблемы науки и образования (Modern Problems of Science and Education)
Verified
Journal Article
Open access
TIT.N. Ismagilov
T.N. Ismagilov
BAB.M. Aznabaev
B.M. Aznabaev
TMT.R. Mukhamadeev
T.R. Mukhamadeev
TDT.I. Dibaev
T.I. Dibaev
AVA.S. Vafiev
A.S. Vafiev

9 January 2019 in Ophthalmology in Russia
Verified
Journal Article
Open access
PDF file
BAB. M. Aznabaev
B. M. Aznabaev
TMT. R. Mukhamadeev
T. R. Mukhamadeev
AAA. A. Aleksandrov
A. A. Aleksandrov
TDT. I. Dibaev
T. I. Dibaev
AVA. S. Vafiev
A. S. Vafiev
ISI. Kh. Shavaliev
I. Kh. Shavaliev
Purpose: to evaluate the efficiency of vitreous floaters removal using the Nd: YAG-laser DIXION LPULSA SYL-9000 with a coaxial light splitter. Patients and Methods. The study involved 24 patients (24 eyes) with Weiss ring-type floating vitreous opacities. All patients underwent laser vitreolysis on a Nd: YAG-laser DIXION LPULSA SYL-9000 with a coaxial light splitter. Laser procedures were performed at OPTIMED Laser Recovery Center. The age of the patients was from 47 to 81 years (average 58.3 ± 8.9 years). Among the patients 15 (62.5 %) were women and 9 (37.5 %) — men. Before procedure, a complete ophthalmological examination including registration of best corrected visual acuity (BCVA), autorefractometry, pneumotonometry, biomicroscopy, fundus examination, ultrasonic biometry, ultrasound B-scan was performed. Statistical processing was performed using Statistica v.10.0.0 (StatSoft®, Inc.) and Excel (Microsoft Office Professional 2016) software. The patients were observed for three months before the procedure. Follow-up examination was performed one day after the procedure. Results. After laser vitreolysis procedure all patients had a subjective vision quality improvement. In 18 (75 %) patients, floating “flies” completely disappeared. The remaining patients noted the disappearance of a large floating spot. Conclusion. The laser vitreolysis on the Nd: YAG-laser with a coaxial light splitter allows to improve the quality and visual acuity in patients with vitreous floater. The obtained results demonstrated that Nd: YAG-laser DIXION LPULSA SYL-9000 is effective and could be recommended for treatment of symptomatic vitreous floaters.