In recent years, terahertz (THz) systems have become an increasingly popular area of research thanks to their unique properties such as extremely high data rates towards Tb/s, submillimeter localization accuracy, high resolution remote sensing of materials, and remarkable advances in photonics and electronics technologies. This article traces the progress of THz measurements, antennas and simulations, from historical milestones to the current state of research and provides an outlook on the remaining challenges.
13 May 2024 in IEEE Transactions on Instrumentation and Measurement
This article investigates the impact of fire on electromagnetic waves within a 70–90 GHz frequency range. To gain a deeper understanding of interactions between fire and radar signals, it is essential to consider a dielectric model for flames. Three primary mechanisms have been identified: the relative permittivity of reaction products, absorption of ionized gases, and the influence of incomplete combustion. To explore these mechanisms, two distinct test fires (TF) were examined in a fire laboratory in a style of the European standard EN54. Initial experimental series involved the combustion of liquid n-heptane, followed by a series of experiments focusing on open polyurethane combustion. Measurements were conducted using a frequency modulated continuous wave radar sensor. Additionally, a PT1000 resistor and an optical extraction measuring instrument were used as reference. Based on highly precise phase evaluation of the measurement signal, initial correlations were established between the radar-measured phase and the measured particle density. The proven ability to differentiate between two TF suggests the potential for fire detection using frequency-modulated continuous wave (FMCW) radar sensors.
6 December 2023 in International Journal of Microwave and Wireless Technologies
Electronic measurement systems in the THz frequency range are often bulky and expensive devices. While some compact single-chip systems operating in the high millimeter-wave frequency range have recently been published, compact measurement systems in the low THz frequency range are still rare. The emergence of new silicon-germanium (SiGe) semiconductor technologies allow the integration of system components, like oscillators, frequency multipliers, frequency dividers, and antennas, operating in the low THz frequency range, into a compact monolithic microwave integrated circuits (MMIC), which contains most components to implement a low-cost and compact frequency-modulated continuous-wave-radar transceiver. This article presents a single transceiver solution containing all necessary components. It introduces a $0.48\,\mathrm{THz}$ radar transceiver MMIC with a tuning range of $43\,\mathrm{GHz}$ and an output power of up to $-9.4\,\mathrm{dBm}$ in the SG13G3 $130\,\mathrm{nm}$ SiGe technology by IHP. The MMIC is complemented by a dielectric lens antenna design consisting of polytetrafluoroethylene, providing up to $39.3\,\mathrm d\mathrm B\mathrm i$ of directivity and half-power beam widths of 0.95∘ in transmit and receive direction. The suppression of clutter from unwanted targets deviating from antenna boresight more than 6∘ is higher than $24.6\,\mathrm d \mathrm B$ in E- and H-Plane.
Simultaneous Localization and Mapping (SLAM) of indoor scenarios is usually based on camera or lidar sensors as data sources. However, radar based room scanning offers several complementary advantages to these systems. Among other features, radar sensors are more robust to optical opacities, for example, those caused by smoke and dust in emergency scenarios or in harsh environments. Furthermore, the coherent measurement principle of radar sensors provides highly precise distance information that can be utilized to track the exact position and dimensions of the visible objects. In contrast to camera and lidar, radar applications in room exploration are up to now limited by reduced spatial, i.e. mostly angular/lateral, resolution. This is due to the comparably large wavelength of the utilized signals. This work demonstrates the capabilities of ultrawideband millimeterwave Frequency Modulated Continuous Wave (FMCW) radar sensors operating around 80 GHz in conjunction with the Synthetic Aperture Radar (SAR) imaging method. To allow imaging whilst moving, self-localization techniques based on sub-aperture processing are evaluated. Therefore, we demonstrate a detailed mapping procedure for room exploration applications by exploiting large absolute bandwidths of more than 20 GHz with high resolution imaging techniques on a mobile robot platform.
30 October 2024 in IEEE Transactions on Microwave Theory and Techniques
Understanding and detecting smoke effectively is crucial in emergency scenarios where traditional optical methods may fail. This article investigates the definition of smoke and its characterization from an electromagnetic perspective, focusing particularly on the use of frequency-modulated continuous wave (FMCW) radar sensors operating in the millimeter-wave range. We explore the influence of both laminar and turbulent smoke flows on the measurement accuracy. Our study is grounded in dielectric models in the millimeter-wave spectrum, demonstrating that the dielectric properties of smoke exhibit minimal variations. Consequently, we use phase-based radar signal processing to detect these subtle changes. Unlike previous studies that primarily evaluate sensor performance, this article aims to use the minimal impact on the measured signal to characterize different smoke scenarios comprehensively. Our findings demonstrate that radar sensors can provide valuable insights into smoke properties and are suitable to extend material model for millimeter-wave frequencies, enhancing situational awareness and response strategies in smoke-obscured environments.
In this contribution, a novel measuring method for the differentiation of intra vascular plaque types is presented. The proposed method operates contact free because of the mm-wave based approach. Fundamentals concerning material properties of blood and plaque, and electromagnetic barrier reflections are discussed. Furthermore, a test setup consisting of a miniaturized sensor setup is introduced that clarifies the measuring concept. Additionally, results of 3D electromagnetic field simulations as well as first measurements ex situ performed on non-human genetic materials are shown and discussed in detail.