Francyelle Calegari

Francyelle Calegari

Auto-generated profile, based on publicly available information

Francyelle Calegari

Mechanical Engineering Department, Federal University of Paraná, Curitiba 81531-980, Brazil

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 June 2011 in Journal of Agricultural and Food Chemistry
Verified
Journal Article
Closed access
LSLismery P. Souza
Lismery P. Souza
FCFrancyelle Calegari
Francyelle Calegari
AZAldo J. G. Zarbin
Aldo J. G. Zarbin
LMLuiz Marcolino-Junior
Luiz Marcolino-Junior
MBMárcio F. Bergamini
Márcio F. Bergamini

1 January 2020 in Progress in Organic Coatings
Verified
Journal Article
Closed access
FCFrancyelle Calegari
Francyelle Calegari
BSBruno C. da Silva
Bruno C. da Silva
João TedimJoão Tedim
João Tedim
Mario FerreiraMario Ferreira
Mario Ferreira
MBMarcos A.C. Berton
Marcos A.C. Berton
CMCLÁUDIA MARINO
CLÁUDIA MARINO

1 December 2017 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
FCFrancyelle Calegari
Francyelle Calegari
LSLismery P. de Souza
Lismery P. de Souza
MBMadalina M. Barsan
Madalina M. Barsan
CBChristopher M.A. Brett
Christopher M.A. Brett
LMLuiz Marcolino-Junior
Luiz Marcolino-Junior
MBMárcio F. Bergamini
Márcio F. Bergamini

9 February 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
FCFrancyelle Calegari
Francyelle Calegari
Isabel de SousaIsabel de Sousa
Isabel de Sousa
Mario FerreiraMario Ferreira
Mario Ferreira
MBMarcos Antonio Coelho Berton
Marcos Antonio Coelho Berton
CMCLÁUDIA MARINO
CLÁUDIA MARINO
João TedimJoão Tedim
João Tedim
Sodium carboxymethylcellulose (CMC-Na) microparticles, containing corrosion inhibitor benzotriazole (BTA), were prepared using different spray drying processing parameters, with the purpose of future application in protective coatings for the delivery of corrosion inhibitors. The effects of the processing parameters, such as inlet temperature and spray flow rate, are discussed herein. The biopolymeric CMC-Na microparticles obtained were characterized morphologically by SEM and TEM, and their release profile studied by UV-Vis. The results show that the prepared microparticles (microspheres) were homogeneous, spherically shaped and of a matrix-type nature. Additionally, it was observed that the inlet temperature and spray flow rate significantly influenced the release profiles and process yields. From the different process parameters tested, it was found that the best conditions to achieve higher process yields, higher encapsulation efficiencies and better release properties, were an inlet temperature of 170 °C, a pump rate of 2.5 mL/min, and a drying air-flow rate of 440 L/h.

4 April 2019 in Analytical Methods
Verified
Journal Article
Closed access
PDF file
FCFrancyelle Calegari
Francyelle Calegari
POPaulo Roberto de Oliveira
Paulo Roberto de Oliveira
LMLuiz Marcolino-Junior
Luiz Marcolino-Junior
MBMarcio Fernando Bergamini
Marcio Fernando Bergamini
This work describes a composite electrode based on carbon black (CB) and poly(ethylene-co-vinyl)acetate (EVA) for development of a robust, low cost and time-saving method for the amperometric determination of hydrochlorothiazide (HCTZ) in a pharmaceutical formulation and synthetic human urine samples. This composite electrode exhibits favourable features such as mechanical resistance, low cost and simple preparation. The proposed electrode was used as an amperometric detector in flow injection analysis (FIA) based on HCTZ oxidation. The best amperometric responses were obtained by employing a composite electrode made with 75% (w/w) carbon black (CB) and 25% (w/w) poly(ethylene-co-vinyl)acetate (EVA), sample volume of 100 μL, flow rate of 5.3 mL min−1 and potential of detection of +900 mV vs. Ag/AgCl/3.0 mol L−1. Under optimized conditions, it was possible to achieve an analytical frequency of 128 injections h−1, a linear dynamic range (LDR) of 10 to 200 μmol L−1, a limit of quantification (LOQ) of 4.4 μmol L−1 and a limit of detection (LOD) of 1.3 μmol L−1 for HCTZ. The proposed method was successfully applied for determination of HCTZ in commercial tablets and synthetic human urine samples without any chemical pretreatment. The composite electrode based on EVA and carbon black is feasible and totally adaptable to portable devices for HCTZ quantification.