12 July 2017 in Indoor and Built Environment
25 August 2017 in Industrial & Engineering Chemistry Research
1 August 2004 in Indoor and Built Environment
A new concept of ‘accessibility’ is presented that considers the influence of supply air or of a contaminant inside ventilated spaces within a finite period of time. Two new indices—accessibility of supply air (ASA) and accessibility of contaminant source (ACS)—are defined to evaluate the relative effect of spread of supply air or contaminant in a given period of time. The two new indices in a two-dimensional ventilated room have been numerically analysed to demonstrate the characteristics of the new concept. It is shown that accessibility increases with the increase of time. For emergency ventilation, people usually care about accessibility in a short period of time, which is usually less than twice the nominal time constant in the ventilated room. The analysis indicates that accessibility over such a period of time is very different from that over an ‘infinite’ period, i.e. the steady state case. The ASA and ACS scale influence the supply of air or contaminant in each zone quantitatively and thus they can be used to guide ventilation strategy, especially when an emergency occurs.
19 October 2012 in Indoor and Built Environment
1 November 2014 in Building and Environment
7 January 2020 in Indoor and Built Environment
Airflow patterns are essential for heating, ventilation and air conditioning (HVAC) systems. Traditional HVAC systems are predesigned and operated using a fixed airflow pattern. However, the indoor occupancy and heat source always vary and therefore, the fixed flow pattern cannot efficiently maintain the required indoor environment conditions. In this study, a novel Adjustable Fan Network (AFN) for improving airflow pattern manoeuvrability is proposed. It integrates multiple small and adjustable axial fans into an AFN, enabling it to change the airflow pattern based on the actual demand with only one set of equipment. Further, the outflow characteristics of two types of axial fans were measured using a quad-view colour sequence particle streak velocimetry (CSPSV) in a test chamber. The ventilation system was then designed based on typical scenarios. Finally, the performance of the AFN was evaluated under different scenarios using a quad-view CSPSV. Based on the results, it was evident that the AFN can provide a better direct supply of air to the occupied zone under different scenarios. With the growing demand for personal thermal comfort and energy-saving in HVAC systems, the novel AFN system has a great potential to be a highly controllable terminal for demand-oriented ventilation.