Haiyang Zhang

Haiyang Zhang

Auto-generated profile, based on publicly available information

Haiyang Zhang

State Key Laboratory of Cryogenic Science and Technology, Technical Institute of Physics and Chemistry (TIPC), Chinese Academy of Sciences (CAS), Beijing 100190, People’s Republic of China

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 August 2017 in Industrial & Engineering Chemistry Research
Verified
Journal Article
Closed access
Wei  WuWei Wu
Wei Wu
HZHaiyang Zhang
Haiyang Zhang
TYTian You
Tian You
XLXianting Li
Xianting Li

19 October 2020 in Metrologia
Verified
Journal Article
Open access
PDF file
BGBo Gao
Bo Gao
HZHaiyang Zhang
Haiyang Zhang
DHDongxu Han
Dongxu Han
CPChangzhao Pan
Changzhao Pan
HCHui Chen
Hui Chen
LPLaurent Pitre
Laurent Pitre
We describe measurements of thermodynamic temperature in the range 5 K to 24.5561 K (the triple point of neon) using single-pressure refractive-index gas thermometry (SPRIGT) with 4He. In the wake of the May 2019 re-definition of the kelvin and its associated mise en pratique, the main purpose of the work is to provide values of T–T 90, the discrepancy between thermodynamic temperature and that of the International Temperature Scale of 1990 (ITS-90). The link to ITS-90 is made via calibrated rhodium-iron resistance thermometers. Innovations required to reach the level of accuracy required for meaningful measurements (uncertainty in T–T 90 less than the expected deviation) include the suppression of temperature oscillations in a cryogen-free cryostat, a pressure stabilization scheme based on a non-rotating piston balance, modelling of the hydrostatic head correction and refinements of the measurement of microwave resonances in a quasi-spherical copper resonator. The accuracy of measurements varies from 0.05 mK to 0.17 mK and is competitive with that of all previous ones in this temperature range using other techniques. The improvement stems partly from the new techniques used for the new definition of the kelvin as well as ab initio calculations of the thermophysical properties ofgaseous 4He. In addition to confirming the validity of SPRIGT as an accurate, easier-to-implement alternative to other low-temperature primary thermometry techniques (e.g. acoustic gas thermometry) yet with scope for improvement, the results should provide important input data for any future revision of ITS-90.

1 October 2018 in Review of Scientific Instruments
Verified
Journal Article
Closed access
BGBo Gao
Bo Gao
CPChangzhao Pan
Changzhao Pan
YCYanyan Chen
Yanyan Chen
YSYaonan Song
Yaonan Song
HZHaiyang Zhang
Haiyang Zhang
LPLaurent Pitre
Laurent Pitre
Single-pressure refractive-index gas thermometry (SPRIGT) is a new type primary thermometry jointly developed by TIPC of CAS in China and LNE-Cnam in France. To realize a competitive uncertainty of 0.25 mK for the thermodynamic temperature measurement, a cryogen-free cryostat with high-stability better than 0.2 mK should be designed. This paper presented the first experimental results of temperature control for this cryostat. To realize this objective, multi-layer radiation shields combined with a thermal-resistance method were used to isolate the thermal-noise from surroundings. Besides, a new temperature control method based on a gas-type heat switch and proportional-integral-derivative control method was proposed, which was applicable to different temperature ranges by changing the working modes of the heat switch. After optimizing, the ultra-high precision temperature control in the range of 5–25 K has been fully realized, which was the temperature instability (with standard deviation) of 0.021 mK at 5.0 K, 0.05 mK at 5.7 K, 0.042 mK at 7.4 K, 0.029 mK at 14.3 K, and 0.022 mK at 25 K with the sampling time of 0.8 s. This was almost the best reporting result in the world and showed its great potential in SPRIGT.

1 October 2018 in The Journal of Chemical Thermodynamics
Verified
Journal Article
Closed access
QZQuan Zhong
Quan Zhong
XDXueqiang Dong
Xueqiang Dong
YZYanxing Zhao
Yanxing Zhao
JWJingzhou Wang
Jingzhou Wang
HZHaiyang Zhang
Haiyang Zhang
MGMaoqiong Gong
Maoqiong Gong

1 January 2019 in Cryogenics
Verified
Journal Article
Closed access
YCYanYan Chen
YanYan Chen
HZHaiyang Zhang
Haiyang Zhang
YSYaonan Song
Yaonan Song
PCPan Changzhao
Pan Changzhao
BGBo Gao
Bo Gao
LPLaurent Pitre
Laurent Pitre

9 July 2021 in Metrologia
Verified
Journal Article
Open access
CPChangzhao Pan
Changzhao Pan
FSFernando Sparasci
Fernando Sparasci
HZHaiyang Zhang
Haiyang Zhang
PGPascal Gambette
Pascal Gambette
MPMark Plimmer
Mark Plimmer
LPLaurent Pitre
Laurent Pitre
We used absolute primary acoustic gas thermometry (AGT) to calibrate a Pt–Co resistance thermometer on the thermodynamic temperature scale by measuring the speed of sound in helium at a temperature T* chosen to be near the temperature of the triple point of neon, T Ne. Prior to the present AGT, the Pt–Co thermometer was used with a neon triple-point cell as part of an interlaboratory comparison. Taken together, the results of the interlaboratory comparison and the present AGT redetermined the thermodynamic temperature T Ne = (24.555 15 ± 0.000 24) K. This new value of T Ne is consistent with other recent determinations obtained with various primary methods. After completing the AGT thermodynamic calibration, we used the Pt–Co thermometer to link T* to the temperature ratios measured by single-pressure refractive-index gas thermometry (SPRIGT) in a different laboratory. (Gao et al 2020 Metrologia 57 065006) Now, the T*-linked SPRIGT system can calibrate other thermometers on the thermodynamic temperature scale T in the range 5 K ⩽ T ⩽ T Ne without using the international temperature scale ITS-90. At most temperatures in this range, the uncertainties of the T*-linked SPRIGT system are smaller than those of the ITS-90 systems used by National Metrology Institutes to calibrate resistance thermometers.