Weiyu Qiao

Weiyu Qiao

Auto-generated profile, based on publicly available information

Weiyu Qiao

CAS Ion (Hangzhou) Medical Technology Company, Ltd

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 February 2026 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
AFAo Feng
Ao Feng
YZYi Zhu
Yi Zhu
YYYanbing Yang
Yanbing Yang
GHGang He
Gang He
WYWei You
Wei You
WYWenjie Yang
Wenjie Yang
When constructing high-field magnets with non-metallic formers, quench protection of slot-type magnets such as DCT and CCT becomes particularly challenging, as non-metallic structures cannot provide the quench-back effect. To address this issue, a 6+1 cable (six superconducting wires and one center cooper wire) configuration has been proposed. During a quench, the central copper strand acts as an internal heater, inducing the quench-back effect. However, the presence of the copper strand reduces the available slot space, thereby limiting the effective engineering current density. To further improve both the current density and protection performance, the coupling-loss induced quench (CLIQ) method has been introduced and applied to seven-strand superconducting cables without a central copper strand. In this study, an electro-thermal coupling model is employed to first validate, through experiment–simulation comparison, the effectiveness of quench-back protection in 6+1 cables. The same model is then extended to analyze and predict the quench protection performance of seven-strand cables under CLIQ. The results demonstrate that CLIQ can effectively trigger uniform quenching, significantly reducing the quench integral and hot-spot temperature, thereby ensuring the reliable protection of the magnet.

19 April 2022 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
WQWeiyu Qiao
Weiyu Qiao
LMLizhen Ma
Lizhen Ma
DNDongsheng Ni
Dongsheng Ni
WWWei Wu
Wei Wu
XWXudong Wang
Xudong Wang
WYWei You
Wei You
AbstractTo cool the superconducting magnets of a compact synchrotron, a forced flow cooling system with cooling capacity of 10.16 watts at 4.5 K based on GM/J-T concept is designed. As a preliminary research of the cooling system, a research device is built. The research device shares a similar flow diagram with the cooling system, but the GM cryocooler is replaced by a cold helium pre-cooling section to searching the system parameters and improve the system response speed. For the research device, the pre-cooling section consumes 0.332 g/s of liquid helium and generates 0.565 g/s of liquid helium after throttling by the J-T valve. To elucidate the performance of the heat exchangers based on enthalpy balance, the cycle point parameters are picked. The results of the thermomechanical analysis show that the temperature, the temperature difference and the pressure of helium at inlet of the JTH section how to affect the cooling capacity of the system. The heat leakage analysis, the design parameters optimization and the cycle efficiency improvement in the system are also discussed in this paper. Index TermsHelium refrigerator, Cryogenic system, Cooling capacity, Thermodynamic analysis

29 October 2026 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
YYYanbing Yang
Yanbing Yang
GCGuangquan Chen
Guangquan Chen
WQWeiyu Qiao
Weiyu Qiao
YZYi Zhu
Yi Zhu
JHJingbin Huo
Jingbin Huo
LMLizhen Ma
Lizhen Ma

29 October 2026 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
AFAo Feng
Ao Feng
PGPengfei Guo
Pengfei Guo
JHJingbin Huo
Jingbin Huo
YZYi Zhu
Yi Zhu
GCGuangquan Chen
Guangquan Chen
WYWenjie Yang
Wenjie Yang

29 March 2022 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
LWLishi Wang
Lishi Wang
XSXingkang Su
Xingkang Su
DNDongsheng Ni
Dongsheng Ni
YZYajun Zheng
Yajun Zheng
XWXudong Wang
Xudong Wang
LMLizhen Ma
Lizhen Ma
The quench phenomenon of the accelerator superconducting magnet may occur in operation, which will cause the liquid helium in the cryostat to evaporate rapidly and release in the atmosphere. High-pressure helium will result in serious damage on significant components in the transmission line, and the released helium in the tunnel will lead to the ODH (Oxygen Deficiency Hazard), threatening the safety of operators. In this paper, the species transport model was used to study the 2D helium discharge process of fragmentation separator in HIAF (High-Intensity heavy-ion Accelerator Facility) by using the platform of computational fluid dynamics software FLUENT. To verify the effectiveness of the species transport model for the FLUENT in simulating the mixing jet process of different components, a 2D FLUENT simulation results of the LHC helium release process was compared with the experimental results and the 3D OpenFOAM simulation results. The results show that the species transport model based on FLUENT could predict the helium release process effectively. Then the distributions of helium concentration, temperature, and velocity in the HFRS (High energy FRagment Separator) tunnel were studied and obtained by the present work. Based on the above analysis, a reasonable design scheme of the accelerator superconducting magnet relief system can be accomplished for HFRS.

28 June 2024 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
WQWeiyu Qiao
Weiyu Qiao
WYWenjie Yang
Wenjie Yang
DNDongsheng Ni
Dongsheng Ni
XQXiangqi Qin
Xiangqi Qin
XOXianjin Ou
Xianjin Ou
LMLizhen Ma
Lizhen Ma
A project to develop core component for heavy-ion Synchrotron is underway in Lanzhou, having started in 2022. The aim of this project is reduced radius of the synchrotron by superconducting magnets. To cool the superconducting magnets of compact Heavy-Ion synchrotron, a pre-cooling helium cryogenic cryocooler is researched. The cryogenic system can generate over 10 watts cooling capacity at temperature of 4.5K. It adopts conduction pre-cooling with GM cryocoolers and is designed to be able to forced flow cooling superconducting magnets. To verify the process design and heat exchanger performance, an open circulation device with the same process as the designed model was built and a cooling test was carried out. As a result of the test, it was confirmed that the heat exchanger can achieve the designed heat transfer temperature. And it was also confirmed that there was a temperature gradient of about 5 K behind J-T valve between the measurement results and the thermal calculation results. The results of the present work shows that the open circulation system can realize rapid cooling and it has reference significance for the design of closed cycle cryogenic system. But there are some cooling process design needs further improvement in a later study.