Ao Feng

Ao Feng

Auto-generated profile, based on publicly available information

Ao Feng

CAS Ion (Hangzhou) Medical Technology Company, Ltd

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 January 2024 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
WLWei Li
Wei Li
JSJinrui Shi
Jinrui Shi
CWChengtao Wang
Chengtao Wang
RKRui Kang
Rui Kang
HZHongjun Zhang
Hongjun Zhang
QXQingjin Xu
Qingjin Xu
Nb 3 Sn is now recognized as the practical material for the high-field applications from 10 to 16 T, for particle accelerators, fusion and other related fields. However, the obtaining of high J c in Nb 3 Sn presently contradicts one of the most important stability criteria: to keep a small filament size, which makes the stability issue particularly prominent. Large filament sizes frequently cause flux jumps in the conductor, making quench detection and protection more challenging for Nb 3 Sn magnets. In this work, we try to numerically simulate the flux jumps more accurately down to a filamentary scale. Based on the theory of superconducting dynamics, we have established a theoretical model to describe the magnetothermal instability of Nb 3 Sn wires by considering the superconductor flux dynamics, heat diffusion and temperature response. The preliminary analysis of the test results for LPF3 which is a 16-T hybrid common coil dipole magnet fabricated by Institute of High Energy Physics is conducted to study the causes of its quenching and the impact of flux jumps on the magnet.

9 February 2026 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
AFAo Feng
Ao Feng
YZYi Zhu
Yi Zhu
YYYanbing Yang
Yanbing Yang
GHGang He
Gang He
WYWei You
Wei You
WYWenjie Yang
Wenjie Yang
When constructing high-field magnets with non-metallic formers, quench protection of slot-type magnets such as DCT and CCT becomes particularly challenging, as non-metallic structures cannot provide the quench-back effect. To address this issue, a 6+1 cable (six superconducting wires and one center cooper wire) configuration has been proposed. During a quench, the central copper strand acts as an internal heater, inducing the quench-back effect. However, the presence of the copper strand reduces the available slot space, thereby limiting the effective engineering current density. To further improve both the current density and protection performance, the coupling-loss induced quench (CLIQ) method has been introduced and applied to seven-strand superconducting cables without a central copper strand. In this study, an electro-thermal coupling model is employed to first validate, through experiment–simulation comparison, the effectiveness of quench-back protection in 6+1 cables. The same model is then extended to analyze and predict the quench protection performance of seven-strand cables under CLIQ. The results demonstrate that CLIQ can effectively trigger uniform quenching, significantly reducing the quench integral and hot-spot temperature, thereby ensuring the reliable protection of the magnet.

29 October 2026 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
YYYanbing Yang
Yanbing Yang
GCGuangquan Chen
Guangquan Chen
WQWeiyu Qiao
Weiyu Qiao
YZYi Zhu
Yi Zhu
JHJingbin Huo
Jingbin Huo
LMLizhen Ma
Lizhen Ma

1 October 2026 in Superconductor Science and Technology
Verified
Journal Article
Closed access
YLYiqin Lei
Yiqin Lei
LMLizhen Ma
Lizhen Ma
WYWenjie Yang
Wenjie Yang
YWYou Wei
You Wei
YLYu Liang
Yu Liang
BBBiaokun Bai
Biaokun Bai
A helium-free fast-ramping dipole–quadrupole combined-function superconducting magnet based on discrete cosine theta coils was developed for compact heavy-ion therapy gantry applications. Under rapid excitation conditions, significant AC losses and eddy-current losses are generated in both superconducting coils and conductive structures, posing challenges to thermal stability under conduction cooling. In this work, the AC-loss distribution was evaluated using a spatially resolved method combining the spatial resolution loss analysis method and the position–field-strength integration method. Based on the calculated heat-load distribution, a 3D ring–axis–radial conduction-cooling structure was designed and optimized to enhance thermal transport while suppressing eddy-current losses. Electromagnetic–thermal coupled simulations and experimental investigations were carried out to analyze the steady-state and transient thermal behavior under cyclic fast-ramping operation. The results show that the total dynamic loss is approximately 6.4 W under practical operating conditions with a ramp rate of 0.6 T s −1 . The maximum temperature rise is limited to below 0.6 K during continuous operation and remains within 0.2 K under realistic cyclic excitation conditions. Experimental measurements obtained from both liquid-helium and conduction-cooled tests show satisfactory agreement with numerical predictions, providing experimental support for the proposed thermal management scheme. The present work demonstrates the feasibility of helium-free fast-ramping superconducting gantry magnets for next-generation compact heavy-ion therapy systems.

29 October 2026 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
AFAo Feng
Ao Feng
PGPengfei Guo
Pengfei Guo
JHJingbin Huo
Jingbin Huo
YZYi Zhu
Yi Zhu
GCGuangquan Chen
Guangquan Chen
WYWenjie Yang
Wenjie Yang

11 March 2025 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
GHGang He
Gang He
GZGuoqing Zhang
Guoqing Zhang
WYWenjie Yang
Wenjie Yang
HWHongfei Wang
Hongfei Wang
LHLei He
Lei He
DNDongsheng Ni
Dongsheng Ni
The Dalian Advanced Light Source (DALS) Beam Testing Platform requires a superconducting quadrupole magnet (with X/Y correction coils) to be installed at the end of the cryomodule to focus the beam. This quadrupole magnet has an aperture of 81 mm, a field gradient of 8 T/m, an integrated X/Y correction field of 67 Gs-m, and an magnetic length of 0.23 m. The non-uniformity of the quadrupole field within ±15 mm of the center is controlled to 0.1%, with a leakage field below 5 mGs at 10 cm from the cavity end. Considering magnetic field performance, cost-efficiency, and reliability, a conduction-cooled racetrack coil with an iron core structure was chosen, enabling the quadrupole and X/Y correction coils to share a common pole structure [M. Masuzawa et al., Jun. 2013]. Furthermore, since the SCRF cavities must be installed in a clean environment [V. S. Kashikhin et al., Jun. 2012], the magnet is designed with a vertically split structure, allowing for assembly in the cryomodule after the SCRF cavity string has been installed in the clean room [V. Kashikhin et al., Jun. 2016], [V. S. Kashikhin, Jun. 2008], [V. S. Kashikhin et al., Jun. 2009], and [V. S. Kashikhin et al., Jun. 2012]. This paper presents the magnetic field design, mechanical structure, thermal analysis, quench protection, and manufacturing of the superconducting quadrupole magnet. Finally, the magnet was tested in a cryogenic liquid helium bath, with detailed measurements of the magnetic field distribution.