Jun Kishihara

Jun Kishihara

Auto-generated profile, based on publicly available information

Jun Kishihara

Department of Cardiovascular Medicine Kitasato University School of Medicine Sagamihara Kanagawa Japan

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 March 2019 in Circulation Journal
Verified
Journal Article
Open access
PDF file
RNRyo Nishinarita
Ryo Nishinarita
SNShinichi Niwano
Shinichi Niwano
HFHidehira Fukaya
Hidehira Fukaya
JOJun Oikawa
Jun Oikawa
TNTakeru Nabeta
Takeru Nabeta
JAJunya Ako
Junya Ako
Background: The relationship between atrial high-rate episode (AHRE) burden (i.e., the frequency of atrial tachyarrhythmia) and heart failure (HF) risk is unclear. We hypothesized that new-onset and higher burden of AHRE are associated with HF. Methods and Results: We included 104 consecutive patients with cardiac implantable electronic devices (CIEDs) capable of continuous atrial rhythm monitoring. Patients with AF history were excluded. To stratify patients, AHREs were evaluated only during the initial 1 year after CIED implantation. The primary endpoint was all-cause death or new-onset or worsening HF that required unplanned hospitalization or readjustment of HF drug therapy. At 1 year after CIED implantation, 34/104 patients (33%) exhibited AHREs. No difference in basal clinical characteristics except for left ventricular ejection fraction between patients with and without new-onset AHREs was found. AHRE groups had more HF events than the non-AHRE group. All patients were divided into 3 groups based on AHRE burden: none, low, and high. Worsening HF was observed in 12 patients (12%). Cox hazard analysis revealed that AHRE and higher AHRE burden were independent predictive factors for worsening HF. The high group showed a higher risk for HF than the non-AHRE groups, but no significant difference was found between the low- and non-AHRE groups. Conclusions: New-onset higher AHRE burden was associated with subsequent risk for HF in patients with CIEDs.

1 March 2021 in International Journal of Cardiology
Verified
Journal Article
Closed access
JOJun Oikawa
Jun Oikawa
HFHidehira Fukaya
Hidehira Fukaya
TWTakuya Wada
Takuya Wada
AHAi Horiguchi
Ai Horiguchi
JKJun Kishihara
Jun Kishihara
JAJunya Ako
Junya Ako

10 May 2022 in Journal of Cardiovascular Electrophysiology
Verified
Journal Article
Closed access
JOJun Oikawa
Jun Oikawa
HFHidehira Fukaya
Hidehira Fukaya
TWTakuya Wada
Takuya Wada
JKJun Kishihara
Jun Kishihara
TSTetsuro Sato
Tetsuro Sato
JAJunya Ako
Junya Ako

20 November 2022 in Journal of Cardiovascular Electrophysiology
Verified
Journal Article
Closed access
HFHidehira Fukaya
Hidehira Fukaya
HMHitoshi Mori
Hitoshi Mori
JOJun Oikawa
Jun Oikawa
DKDaisuke Kawano
Daisuke Kawano
HNHironori Nakamura
Hironori Nakamura
SFSeiji Fukamizu
Seiji Fukamizu

1 February 2014
Verified
Journal Article
Closed access
PDF file
JKJun Kishihara
Jun Kishihara
SNShinichi Niwano
Shinichi Niwano
HNHiroe Niwano
Hiroe Niwano
YAYuya Aoyama
Yuya Aoyama
ASAkira Satoh
Akira Satoh
JAJunya Ako
Junya Ako

7 April 2021 in Journal of Arrhythmia
Verified
Journal Article
Open access
PDF file
GMGen Matsuura
Gen Matsuura
JKJun Kishihara
Jun Kishihara
HFHidehira Fukaya
Hidehira Fukaya
JOJun Oikawa
Jun Oikawa
NINaruya Ishizue
Naruya Ishizue
JAJunya Ako
Junya Ako
Background: Although the lesion size index (LSI) has been well established, it is sometimes difficult to achieve first‐pass pulmonary vein isolation (PVI) and to avoid acute pulmonary vein reconnections, even with LSI‐guided procedures. The purpose of this study was to assess the predictive accuracy of a novel parameter, the optimized lesion size index (o‐LSI), to perform PVI.Methods: The voltage maps created by the Advisor™ high‐density (HD) grid catheter before PVI in 35 atrial fibrillation (AF) patients were examined for an association between the voltage amplitude and insufficient ablation sites (IAS), which were defined as either (i) spontaneous reconnection sites, (ii) dormant PV conduction sites unmasked with 20 mg of adenosine triphosphate disodium hydrate (ATP) injection, or (iii) PV‐LA gap sites after the initial PVI.Results: IAS was observed in 25/1417 of the total ablation sites. IAS was significantly associated with higher bipolar voltage areas (4.20 ± 2.68 vs 2.43 ± 1.93 mV, P < .0001) but not with LSI. A novel index, o‐LSI (defined as LSI/bipolar voltage), was significantly lower in IAS than in others (1.14 [0.82, 1.81] vs 2.35 [1.31, 4.80] LSI/mV). By receiver operating characteristic analysis, an o‐LSI of 2.04 was the best cutoff value for the prediction of IAS (88% sensitivity and 55% specificity, P < .0001, areas under the curve: 0.742).Conclusion: Low o‐LSI was strongly associated with IAS, potentially providing a novel index to improve first‐pass PV isolation.