Usman Rizqi Iman

Usman Rizqi Iman

Auto-generated profile, based on publicly available information

Usman Rizqi Iman

Department of Electronic Engineering, Hanyang University, Seoul, South Korea

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2023 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
MZMuhammad Zada
Muhammad Zada
UIUsman Rizqi Iman
Usman Rizqi Iman
ABAbdul Basir
Abdul Basir
HYHyoungsuk Yoo
Hyoungsuk Yoo
Smart textiles—fabrics integrated with electronics—have the potential to revolutionize e-healthcare applications by enabling sensing, communication, and interaction with the environment. This article focuses on developing a battery-free smart-textile-based energy harvester for powering Internet of Things (IoT)-enabled wearable sensors, with a particular emphasis on its application in e-healthcare. The energy harvester is digitally embroidered and can be easily integrated into textile products, including clothing. A multiport design was used, enabling it to harvest energy from multiple directions and convert it into electricity to power wearable sensors. A single element in the proposed multiport energy-harvesting array generates a beam with a peak gain of 7.25 dBi and approximately 68 $^{\circ }$ half-power beamwidth, using a simplified and compact design owing to the absence of complicated feeding networks. The performance of the energy harvester was evaluated through simulations and experiments. Furthermore, the feasibility of integrating the proposed energy harvester into commercially available IoT sensor nodes was demonstrated using a wirelessly powered wearable device. The device was shown to provide real-time temperature and humidity data without external batteries. The use of smart textiles and energy-harvesting technology offers a self-sustaining solution for wearable devices, greatly enhancing their functionality and usability, particularly for e-healthcare applications.

25 July 2024 in IEEE Transactions on Industrial Informatics
Verified
Journal Article
Closed access
UIUsman Rizqi Iman
Usman Rizqi Iman
MZMuhammad Zada
Muhammad Zada
ABAbdul Basir
Abdul Basir
SHShahzeb Hayat
Shahzeb Hayat
YLYoung-Hyo Lim
Young-Hyo Lim
HYHyoungsuk Yoo
Hyoungsuk Yoo
Textiles integrated with electronics and long-range (LoRa) wireless technology are revolutionizing e-healthcare by enabling remote patient monitoring through wireless body area networks. This article presents a smart textile-based LoRa technology system for monitoring heart rate and predicting body temperature over both short and long distances. The system incorporates a LoRa module integrated with a smart textile, featuring sensors for photoplethysmography, electrocardiography, and body temperature monitoring. An embroidered monopole antenna seamlessly integrates into clothing, offering triple-band wideband operation at 433, 610, and 915 MHz with minimal susceptibility to human body effects and structural deformations. The proposed wearable antenna, assessed through specific absorption rate analysis, exhibits minimal exposure to electromagnetic radiation, ensuring user safety. The smart textile LoRa-enabled healthcare application (STLHA) monitors the received signal strength indicator, heart rate, and temperature data. Experimental results demonstrate effective outdoor communication ranges of up to 250 m at 915 MHz and 350 m at 433 MHz, with indoor ranges of up to 50 m. The STLHA offers a wireless solution for wearable devices, which enhances their functionality and usability in e-healthcare applications.

5 November 2024 in IEEE Internet of Things Journal
Verified
Journal Article
Closed access
ISIzaz Ali Shah
Izaz Ali Shah
MZMuhammad Zada
Muhammad Zada
ABAbdul Basir
Abdul Basir
Syed Ahson Ali ShahSyed Ahson Ali Shah
Syed Ahson Ali Shah
UIUsman Rizqi Iman
Usman Rizqi Iman
HYHyoungsuk Yoo
Hyoungsuk Yoo
Leadless cardiac pacemakers (LCPs) enhance health technology by offering a minimally invasive and reliable solution for cardiac pacing; however, their reliance on batteries poses a challenge to achieving extended device longevity. This study proposes an efficient wireless power transfer (WPT) system for LCP devices, in which the dynamic misalignments caused by the natural contraction and relaxation of heart muscles during cardiac cycles and respiratory movements are characterized for the first time. The system comprised an off-body transmitter (Tx) and an in-body rectifier-integrated conformal receiver antenna (Rx). A single-band Tx is optimized to deliver the power wirelessly in the 915 MHz frequency band, whereas the Rx element is configured to offer dual-band characteristics at 433 MHz (data-telemetric mode) and 915 MHz (power reception mode). In addition to the peak gains of −30.6 and −24.8 dBi at the respective lower and higher frequency bands, the Rx exhibited a wireless power reception efficiency of up to 0.53% with a harvested voltage of more than 3 V at 55 mm Tx-Rx separation. The simulation results were experimentally validated in a heart-mimicking phantom, demonstrating the effectiveness of the proposed WPT system in maintaining robust power delivery even in the presence of misalignments induced by physiological motions. Moreover, the rectifier’s measured efficiency of 82% emphasizes its effective power delivery from the perspective of commercial pacemakers. In addition, a WPT-enabled real-time wireless biotelemetric communication link was established, highlighting the system’s potential as a versatile Internet of Medical Things (IoMT) platform for monitoring various real-time physiological parameters.

2 April 2024 in IEEE Internet of Things Journal
Verified
Journal Article
Closed access
SISaiful Islam
Saiful Islam
MZMuhammad Zada
Muhammad Zada
UIUsman Rizqi Iman
Usman Rizqi Iman
HYHyoungsuk Yoo
Hyoungsuk Yoo
We introduced a circularly arranged Vivaldi endfire antenna array combined with nona-band rectifiers to enhance the capability of receiving electromagnetic power to supply power for Internet of Things (IoT) devices. The rectifier encompasses frequencies of 0.9, 1.4, 1.8, 2.1, 2.4, 2.6, 3.5, 4.9, and 5.8 GHz, primarily covering telecom and Wi-Fi operating frequencies. Higher efficiency values at a lower input power of -10 dBm were achieved as 73.98%, 54.54%, 63.16%, 27.14%, 59.58%, 56.60%, 46.62%, 21.43, and 20.64% at 0.9, 1.4, 1.8, 2.1, 2.4, 2.6, 3.5, 4.9, and 5.8 GHz, respectively. In addition to the rectifier, we designed a wideband endfire Vivaldi antenna with a 3–8 dB gain over the operating frequencies, with an efficiency exceeding 80%. To further boost the received power, the antenna rectifier was transformed into an eight-element-based circular array, enabling multibeam and full-azimuth power reception coverage. We validated the performance of the rectifier and antenna by fabricating an energy-harvester array. Furthermore, we demonstrate the IoT device operation to illustrate the practical application of our proposed system.

2 June 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
ZAZain Ul Abdin
Zain Ul Abdin
Syed Ahson Ali ShahSyed Ahson Ali Shah
Syed Ahson Ali Shah
ISIzaz Ali Shah
Izaz Ali Shah
UIUsman Rizqi Iman
Usman Rizqi Iman
SMSajjad Hussain Mian
Sajjad Hussain Mian
HYHyoungsuk Yoo
Hyoungsuk Yoo
Recent advancements in the Internet of Medical Things (IoMT) have necessitated the need of smart biomedical devices. This paper presents a novel endovascular aneurysm repair (EVAR) stent system integrated with a flexible antenna for seamless data telemetry and post-EVAR surveillance with high data rates. Employing multiple-input multiple-output (MIMO) technology, the antenna consists of four dipoles with each element designed and optimized to offer dual band resonance at the two industrial, scientific, and medical (ISM) bands, i.e., 915 and 2450 MHz. To validate the performance of MIMO EVAR stent antenna, simulations were conducted both in the homogeneous tissue and realistic human model. Experimental validations were performed in a saline-filled American Society for Testing and Materials phantom and minced pork. The MIMO stent antenna exhibits several key features including better impedance matching characteristics, high impedance bandwidth of 380 MHz (720–1100 MHz) and 440 MHz (2240–2680 MHz), and excellent far-field radiation performance with high gain values of -11.5 and -9.8 at 915 and 2450 MHz, respectively. Remarkably, the proposed IoMT-enabled smart medical device can support a high data rate of 12 Mbps with the communication range up to 11 m at 915 MHz and 13 m at 2450 MHz, achieved in a real-time data telemetry experiment. Moreover, the MIMO channel parameters were examined to ensure seamless communication and independence between MIMO elements. Specific absorption rate analysis confirmed the safety of the proposed MIMO antenna system. To the best of the authors’ knowledge, this is the first study to develop MIMO-based EVAR stent system with significant features, thereby making it a viable solution for advanced IoMT-enabled healthcare systems.

16 September 2025 in IEEE Journal on Selected Areas in Communications
Verified
Journal Article
Closed access
UIUsman Rizqi Iman
Usman Rizqi Iman
ISIzaz Ali Shah
Izaz Ali Shah
ZAZain Ul Abdin
Zain Ul Abdin
AHAli Ahsan Hasnain
Ali Ahsan Hasnain
HYHyoungsuk Yoo
Hyoungsuk Yoo
WiFi’s high data throughput and robust connectivity, combined with Integrated Sensing and Communication (ISAC), facilitate seamless real-time video transmission, ensuring minimal interference and high-quality imaging for clinical applications such as wireless capsule endoscopy (WCE). The proposed system incorporates a novel ultrawideband (UWB) conformal antenna with the 2.45 GHz band, specifically supporting a WiFi-based system to enable high-speed wireless communication within the human body. By leveraging ISAC, the system efficiently integrates real-time sensing and communication, optimizing data transmission while maintaining signal integrity in dynamic in-body environments. The capsule is equipped with a miniaturized camera module that captures high-resolution images and transmits video data in real-time to an external receiver via a low-latency WiFi communication module. A comprehensive system architecture was developed, integrating Internet of Medical Things (IoMT) connectivity, a cloud-based processing framework, and an optimized node-based transmission mechanism for seamless data relay. To evaluate the system’s performance, experiments were conducted in a realistic environment, simulating human tissue conditions. Results demonstrate video transmission over distances of up to 5 meters, ensuring reliable and high-fidelity endoscopic visualization. The experimental findings validate the feasibility of WiFi-powered WCE for continuous gastrointestinal monitoring, highlighting its potential for real-time diagnostics, remote healthcare, and telemedicine applications.